The Recall Desk

Agency

National Highway Traffic Safety Administration

NHTSA oversees recalls of vehicles, tires, child seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA campaign number.

Visit the official NHTSA site →

About NHTSA recalls

NHTSA regulates the safety of every motor vehicle sold in the US plus tires, child seats, and motor-vehicle equipment. Recalls are coordinated under a numbering scheme called the NHTSA Campaign Number — a string like 25V123000 where the first two digits are the year, V is for vehicle (T is for tires, C for child seats, E for equipment), and the rest identifies the campaign. Every vehicle in our database can be looked up by VIN to check whether any active campaigns affect it.

NHTSA recalls are unusual in two ways. First, the cause is usually a defined defect or non-compliance with a Federal Motor Vehicle Safety Standard rather than a pathogen or contamination event — so 'severity' tracks the consequence of the defect (does the airbag fail to deploy, does the steering lose assist, does the fuel tank leak) rather than reported illnesses. Second, every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, for as long as the vehicle is on the road. There's no expiration on a NHTSA campaign.

We enrich every recall with the full make / model / year-range affected so you can see at a glance whether your vehicle is in scope. If you're not sure, the VIN lookup decodes your specific vehicle and cross-references the database. The remedy is always free — usually a dealer visit for a part replacement, software update, or inspection.

11276–11300 of 15413

  • HighNHTSA·15V467000·2015-07-27

    Dodge Charger Recall for Overly Sensitive Side Impact Sensors

    Chrysler is recalling 2011-2014 Dodge Chargers because overly sensitive side impact sensors may cause air bags to deploy unexpectedly, increasing crash risk.

    Product
    DODGE — DODGE CHARGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V462000·2015-07-24

    Forest River Recalls 2007-2015 Glaval Bus Titan II for Electrical Fire Risk

    Forest River is recalling 2007-2015 Glaval Bus Titan II vehicles due to a misrouted electrical cable that may cause a loose connection or arching, increasing the risk of a vehicle fire.

    Product
    GLAVAL BUS — GLAVAL BUS TITAN II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V463000·2015-07-24

    General Motors Recalls 2013-2016 Cadillac ATS for Sunroof Defect

    General Motors is recalling 2013-2016 Cadillac ATS vehicles because the sunroof may close automatically if the switch is pressed inadvertently, posing a risk of personal injury.

    Product
    CADILLAC — CADILLAC ATS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V464000·2015-07-24

    Ford Recalls 2015-2016 Vehicles Due to Parking Brake Defect

    Ford is recalling specific 2015-2016 models because the parking brake may not fully engage, increasing the risk of the vehicle rolling away on a slope.

    Product
    FORD — FORD, LINCOLN EXPLORER, MKT, MKS, FLEX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V461000·2015-07-23

    Chrysler Recalls 2013-2015 Vehicles for Radio Software Vulnerability

    Chrysler is recalling specific 2013-2015 Ram, Jeep, Dodge, and Chrysler vehicles because radio software vulnerabilities allow unauthorized remote access to vehicle control systems, increasing crash risk.

    Product
    RAM — RAM, JEEP, DODGE 5500, 1500, CHEROKEE, VIPER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V457000·2015-07-22

    Kenworth Trucks Recalled for Reversed Air Brake Line Installation

    PACCAR is recalling 2016 Kenworth trucks because reversed air brake lines may prevent the redundant braking system from working correctly during a failure.

    Product
    KENWORTH — KENWORTH T660, T680, T880, T440
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V456000·2015-07-22

    Peterbilt Trucks Recalled for Alternator Cable Chafing Fire Risk

    PACCAR is recalling 2012-2016 Peterbilt trucks because alternator cables may chafe against a metal line, creating a fire risk.

    Product
    PETERBILT — PETERBILT 365, 587, 386, 567
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V459000·2015-07-22

    Chrysler Recalls Ram Trucks Due to Air Bag Wiring Harness Defect

    Chrysler is recalling 2012-2014 Ram trucks because a steering wheel wiring harness may rub against the air bag retainer, potentially causing unexpected air bag deployment.

    Product
    DODGE — DODGE, RAM RAM 5500, 4500, RAM 4500, RAM 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V460000·2015-07-22

    Chrysler Recalls 2013-2015 Ram Trucks for Air Bag Deployment Risk

    Chrysler is recalling 2013-2015 Ram 1500, 2500, and 3500 trucks because side air bags and seat belts may deploy unexpectedly, increasing crash risk.

    Product
    RAM — RAM 3500, 2500, 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V458000·2015-07-22

    Kenworth Trucks Recalled for Hazard Light Override Defect

    PACCAR is recalling 2011-2016 Kenworth trucks because daytime running lamps may override hazard warning lights, increasing crash risk.

    Product
    KENWORTH — KENWORTH T440, T470, T880, T680
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V454000·2015-07-21

    Allied Recreation Recalls 2016 Motorhomes Due to Propane Regulator Defect

    Allied Recreation Group is recalling 92 model year 2016 motorhomes because an incorrect propane regulator may allow moisture buildup, potentially causing a gas leak and fire.

    Product
    FLEETWOOD — FLEETWOOD, MONACO, HOLIDAY RAMBLER TIOGA RANGER, TREK, TERRA SE, STORM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V451000·2015-07-20

    Mazda Recalls 2007-2014 CX-9 Vehicles for Front Suspension Defect

    Mazda is recalling 2007-2014 CX-9 vehicles because front suspension ball joints may corrode, potentially causing loss of steering control and increasing crash risk.

    Product
    MAZDA — MAZDA CX-9
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15E061000·2015-07-17

    SAF-Holland Recalls CBX Series Trailer Suspension Systems for Pivot Bolt Failure

    SAF-Holland is recalling CBX series trailer suspension systems because pivot bolts may fail, potentially causing the axle to separate from the trailer and increasing crash risk.

    Product
    SUSPENSION:REAR:AXLE:NON-POWERED AXLE ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V450000·2015-07-17

    BMW Recalls 2014-2015 MINI Cooper Models for Side Impact Defect

    BMW is recalling 2014-2015 MINI Cooper, Cooper S, and John Cooper Works vehicles because rear seats fail federal side impact safety standards, increasing injury risk.

    Product
    MINI — MINI JOHN COOPER WORKS, COOPER S, COOPER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15E062000·2015-07-17

    H&H Sports Protection Recalls VCAN V528 Milano Motorcycle Helmets

    H&H Sports Protection is recalling VCAN V528 Milano motorcycle helmets because the retention systems failed testing and required labeling is missing.

    Product
    EQUIPMENT:MOTORCYCLE:HELMETS recall
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·15T014000·2015-07-17

    Continental ContiProContact Tires Recalled for Bead Air Leak Defect

    Continental is recalling specific ContiProContact tires manufactured in early 2015 because a manufacturing error may cause air leaks from the bead area, increasing the risk of sudden tire failure and a crash.

    Product
    TIRES:BEAD recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15E060000·2015-07-15

    Flex-A-Lite Recalls Electric Fan Kits Due to Fire Risk

    Flex-A-Lite is recalling specific electric fan kits because missing fuse holders and insufficient circuit breakers may cause electrical damage and vehicle fires.

    Product
    ENGINE AND ENGINE COOLING:COOLING SYSTEM:FAN recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V448000·2015-07-15

    Spartan Emergency Response Vehicles Recalled for Valve Stem Wear

    Spartan is recalling 2007-2015 emergency response vehicles because front wheel valve stems may rub against brake calipers, causing sudden tire deflation.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR, ADVANTAGE, DIAMOND
    Category
    Vehicle
    Distribution
    Distributed nationwide