The Recall Desk

Agency

National Highway Traffic Safety Administration

NHTSA oversees recalls of vehicles, tires, child seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA campaign number.

Visit the official NHTSA site →

About NHTSA recalls

NHTSA regulates the safety of every motor vehicle sold in the US plus tires, child seats, and motor-vehicle equipment. Recalls are coordinated under a numbering scheme called the NHTSA Campaign Number — a string like 25V123000 where the first two digits are the year, V is for vehicle (T is for tires, C for child seats, E for equipment), and the rest identifies the campaign. Every vehicle in our database can be looked up by VIN to check whether any active campaigns affect it.

NHTSA recalls are unusual in two ways. First, the cause is usually a defined defect or non-compliance with a Federal Motor Vehicle Safety Standard rather than a pathogen or contamination event — so 'severity' tracks the consequence of the defect (does the airbag fail to deploy, does the steering lose assist, does the fuel tank leak) rather than reported illnesses. Second, every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, for as long as the vehicle is on the road. There's no expiration on a NHTSA campaign.

We enrich every recall with the full make / model / year-range affected so you can see at a glance whether your vehicle is in scope. If you're not sure, the VIN lookup decodes your specific vehicle and cross-references the database. The remedy is always free — usually a dealer visit for a part replacement, software update, or inspection.

701–725 of 15399

  • SevereNHTSA·26V081000·2026-02-11

    Nissan Rogue electronic throttle body gears may break during driving

    Nissan is recalling certain 2024-2025 Rogue vehicles with the 1.5L VC-Turbo engine because the gears in the electronic throttle body assembly may break, causing a loss of drive power.

    Product
    NISSAN — NISSAN ROGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V078000·2026-02-11

    Triumph motorcycle alternator wiring may short circuit and overheat

    Triumph is recalling certain 2022-2024 Bonneville, Street Twin, Street Scrambler, Speed Twin 900 and Scrambler 900 motorcycles because the wiring between the alternator and main harness connector may short circuit.

    Product
    TRIUMPH — TRIUMPH SCRAMBLER 900, STREET SCRAMBLER, STREET SCRAMBLER SANDSTOR, BONNEVILLE T100
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V079000·2026-02-11

    Western Star battery to starter stud may short circuit

    Daimler Trucks is recalling certain 2020-2027 Western Star 49X and 2021-2027 47X vehicles because a stud connecting the battery to the starter may be incorrectly installed or may corrode.

    Product
    WESTERN STAR — WESTERN STAR 47X, 49X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26T006000·2026-02-10

    Vee Tyre Recalls Taiga AT Tires Due to Sidewall Separation Risk

    Vee Tyre is recalling specific Taiga AT tires because the sidewall and inner liner may crack and separate, increasing the risk of a crash.

    Product
    TIRES:SIDEWALL recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V076000·2026-02-10

    2024–2027 Volvo VNL (4) trucks recalled for inadequate parking brake

    Volvo Trucks is recalling certain 2024–2027 VNL (4) vehicles lacking auxiliary parking brakes, which can result in inadequate parking brake force and rollaway risk.

    Product
    VOLVO — VOLVO VNL (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V075000·2026-02-09

    Harley-Davidson Sportster S upper triple clamp may fracture during use

    Harley-Davidson is recalling certain 2021-2026 RH1250S Sportster S motorcycles because the upper triple clamp may fracture, which can lead to a loss of control.

    Product
    HARLEY-DAVIDSON — HARLEY-DAVIDSON RH1250S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V074000·2026-02-08

    Oshkosh Recalls 2025-2026 NGDV Vehicles Due to Brake Pedal Defect

    Oshkosh is recalling 2025-2026 NGDV and NGDV Electric vehicles because the brake pedal mounting pin and clip may be missing, risking loss of braking ability.

    Product
    OSHKOSH — OSHKOSH NGDV ELECTRIC, NGDV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V072000·2026-02-06

    Volvo Recalls 2017 S60L Vehicles Due to Door Latch Defect

    Volvo is recalling 2,758 2017 S60L vehicles because a door latch component may break, preventing the door from latching securely and increasing injury risk.

    Product
    VOLVO — VOLVO S60L
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V070000·2026-02-06

    Mercedes-Benz Metris air bag control unit may accumulate water

    Daimler Vans USA is recalling certain 2020 and 2022-2023 Mercedes-Benz Metris right-hand-drive vehicles because water may accumulate on the air bag control unit and stop the air bags deploying as intended.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ METRIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V073000·2026-02-06

    Mercedes-Benz EQB high voltage battery may fail internally and catch fire

    Mercedes-Benz is recalling certain 2022-2024 EQB vehicles because the high voltage battery may fail internally and lead to a vehicle fire while parked or driving. Owners are advised to park outside.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ EQB 250+, EQB 350 4MATIC, EQB 300 4MATIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V067000·2026-02-05

    Jaguar I-PACE high voltage battery may overheat increasing fire risk

    Jaguar is recalling certain 2020-2021 I-PACE vehicles because the high voltage battery may overheat. Owners are advised to park and charge outside and limit charging to 90%.

    Product
    JAGUAR — JAGUAR I-PACE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V069000·2026-02-05

    2026 Hyundai Kona vehicles recalled for front steering knuckle defect

    Hyundai is recalling certain 2026 Kona vehicles because the front steering knuckles may crack and break due to a manufacturing error, which can cause loss of steering control and increase crash risk.

    Product
    HYUNDAI — HYUNDAI KONA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V068000·2026-02-05

    Hyundai IONIQ battery bus bar may be improperly tightened

    Hyundai is recalling certain 2025-2026 IONIQ 5 and 2026 IONIQ 9 vehicles because the high voltage battery system may contain an improperly tightened bus bar, which can cause a short circuit.

    Product
    HYUNDAI — HYUNDAI IONIQ 5, IONIQ 9
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V063000·2026-02-04

    Mercedes-Benz Tourrider Buses Recalled for Door Control Valve Defect

    Daimler Coaches is recalling 2026 Mercedes-Benz Tourrider buses because a faulty door valve may prevent doors from opening, delaying emergency evacuation.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ TOURRIDER PREMIUM, TOURRIDER BUSINESS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V064000·2026-02-04

    BMW Recalls 2026 Gran Coupe Models for Rear Light Defects

    BMW is recalling 2026 228i and M235i Gran Coupe vehicles because rear lights may not function properly, increasing crash risk.

    Product
    BMW — BMW 228I XDRIVE GRAN COUPE, 228I GRAN COUPE, M235I XDRIVE GRAN COUPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·26V065000·2026-02-04

    Ember travel trailer certification labels may list incorrect weight information

    Ember is recalling certain 2026 E-Series and Overland Series travel trailers because the Federal Certification Label may list incorrect unloaded vehicle weight and cargo carrying capacity information.

    Product
    EMBER — EMBER E-SERIES, OVERLAND SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V062000·2026-02-03

    Ford Recalls 2026 E-Transit Vehicles Due to Battery Fire Risk

    Ford is recalling 2026 E-Transit vehicles because missing washers in the high-voltage battery pack may cause electrical arcing, increasing the risk of fire or loss of drive power.

    Product
    FORD — FORD E-TRANSIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V061000·2026-02-03

    Ford Recalls 2023-2024 Transit Vehicles Due to Engine Crossmember Defect

    Ford is recalling 2023-2024 Transit vehicles because an improperly secured engine crossmember may cause the engine to shift, potentially leading to loss of drive power or brake failure.

    Product
    FORD — FORD TRANSIT
    Category
    Vehicle
    Distribution
    Distributed nationwide