The Recall Desk

Vehicle

Winnebago Vista

24 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–24 of 24

  • Severity pendingNHTSA·14V506000·2014-08-18

    Winnebago Vista and Itasca Sunstar Motorhomes Recalled for Fire Risk

    Winnebago is recalling 2015 Vista and Itasca Sunstar motorhomes because a missing damper plate could allow air to blow out the range flame, potentially causing a propane fire.

    Product
    WINNEBAGO — WINNEBAGO VISTA, ITASCA SUNSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V453000·2012-09-14

    Winnebago and Itasca Motor Homes Recalled for Steering Gear Bracket Defect

    Winnebago is recalling 2013 Itasca and Winnebago motor homes because steering gear bracket bolts may fracture, potentially causing loss of vehicle control.

    Product
    ITASCA — ITASCA, WINNEBAGO SUNCRUISER, VISTA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V389000·2012-08-08

    Winnebago and Itasca Motor Homes Recalled for Propane Tubing Defect

    Winnebago is recalling 2012-2013 motor homes because scored copper propane tubing may fail, risking fire or explosion.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA COMMERCIAL VEHICLE, REYO, VIEW PROFILE, VISTA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V525000·2010-10-26

    Winnebago Recalls Recreational Vehicles with Norcold Refrigerator Fire Risk

    Winnebago is recalling certain recreational vehicles equipped with 1200-series Norcold refrigerators because the safety shut-off mechanism may not prevent a fire from a hydrogen gas leak.

    Product
    ITASCA — ITASCA, WINNEBAGO HORIZON, VECTRA GRAND TOUR, SUNOVA, CHIEFTAIN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V390000·2010-09-01

    Winnebago Vista and Itasca Sunstar Motor Homes Recalled for Wiring Hazard

    Winnebago is recalling 2011 Vista and Itasca Sunstar motor homes because a cable may contact the driveshaft, potentially causing electrical shock.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA VISTA, SUNSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V826000·2024-11-01

    Winnebago and Itasca Recreational Vehicles Recalled for Hood Bracket Detachment

    Winnebago Industries is recalling certain 2014-2025 RVs because hood bracket adhesive may have been incorrectly applied, allowing the bracket to detach and create a crash hazard. Dealers will provide free inspection and repair.

    Product
    ITASCA — ITASCA, WINNEBAGO SUNCRUISER, ADVENTURER, COMMERCIAL VEHICLE, VISTA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V733000·2024-10-01

    Winnebago motorhomes recalled for defective turn signals

    Winnebago Industries recalls multiple motorhome models because turn signals may have insufficient lens area, making them difficult for other drivers to see and increasing crash risk. Dealers will replace the turn signals at no cost.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA INTENT, JOURNEY, SUNSTAR, TOUR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V613000·2024-08-15

    Winnebago Sunstar Motorhome Wiring Defect Disables Safety Systems

    Winnebago is recalling certain 2023-2025 Sunstar motorhomes because wiring was incorrectly routed, potentially damaging the forward-facing camera. This can disable active brake assist, lane keep assist, and auto high beams, increasing crash risk.

    Product
    WINNEBAGO — WINNEBAGO ADVENTURER, SUNSTAR, VISTA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V295000·2024-04-26

    Winnebago motorhome cooktop circuit boards may fail and overheat

    Winnebago Industries is recalling certain 2021-2025 motorhomes because the LED backlight circuit board in the cooktop range may fail and overheat. 1,166 units affected.

    Product
    WINNEBAGO — WINNEBAGO PORTO, CAMBRIA, VITA, FORZA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V365000·2023-05-24

    Loose Seat Belt Attachment in Winnebago and Itasca Motorhomes

    Winnebago and Itasca recall certain 2020-2023 motorhomes due to improperly tightened seat belt attachments that may fail to restrain occupants in a crash. Dealers will tighten fasteners free of charge.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA INSPIRE, ADVENTURER, VISTA, SHELL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V140000·2023-03-02

    2023 Winnebago Adventurer, Vista, Sunstar motorhomes recalled for missing rear reflectors

    Winnebago is recalling certain 2023 Adventurer, Vista, and Itasca Sunstar motorhomes for missing rear reflectors that fail federal safety standards. Missing reflectors reduce visibility to other drivers, increasing crash risk.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA VISTA, ADVENTURER, SUNSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V703000·2020-11-13

    2021 Winnebago Motorhomes Recalled for Power Bed Motor Failure Risk

    Certain 2021 Winnebago motorhomes are being recalled because the power bed motor may fail internally, causing the bed to extend before the safety strap engages. This can result in the bed falling unexpectedly, posing a risk of injury or death.

    Product
    WINNEBAGO — WINNEBAGO VISTA, ADVENTURER, REVEL, SUNSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V811000·2019-11-13

    Winnebago Recalls 2017-2020 Motorhomes Due to Electrical Fire Risk

    Winnebago is recalling 2017-2020 Itasca Vista, Sunstar, and Adventurer 35F motorhomes because an improperly mounted electrical connector poses a fire risk if the floor gets wet.

    Product
    WINNEBAGO — WINNEBAGO VISTA, SUNSTAR, ADVENTURER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V782000·2017-12-07

    Winnebago and Itasca Motorhomes Recalled for Defective Fire Extinguishers

    Winnebago is recalling 2013-2018 motorhomes because Kidde fire extinguishers may clog or detach, increasing injury risk during a fire.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA FORZA, TOUR, SIGHTSEER, REVEL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V598000·2016-08-12

    Winnebago Recalls 2015-2017 Recreational Vehicles Due to Electrical Fire Risk

    Winnebago is recalling 2015-2017 Itasca and Winnebago recreational vehicles because a loose electrical connection may cause heat buildup and increase the risk of a fire.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA FUSE, CAMBRIA, ASPECT, TRAVATO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V866000·2015-12-22

    Winnebago and Itasca Motorhomes Recalled for Step Deployment Defect

    Winnebago is recalling 2015-2016 Sightseer, Vista, Adventurer, Sunova, Sunstar, and Suncruiser motorhomes because electric steps may extend while driving, increasing crash risk.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA VISTA, SUNOVA, SIGHTSEER, ADVENTURER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V749000·2015-11-12

    Winnebago Recalls Wheelchair Lifts Due to Bearing Failure Risk

    Winnebago is recalling specific 2008-2012 recreational vehicles because wheelchair lift bearings may shift, causing the platform to fall and injure the operator.

    Product
    WINNEBAGO — WINNEBAGO VISTA, ASPECT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V664000·2015-10-16

    Winnebago and Itasca Motorhomes Recalled for Transmission Shift Cable Defect

    Winnebago is recalling 2015-2016 Brave, Sightseer, Vista, Adventurer, and Itasca models because they can shift out of park without brakes applied.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA SIGHTSEER, VISTA, BRAVE, ADVENTURER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V510000·2015-08-12

    Winnebago Recalls 2014-2015 Motorhomes Due to Stuck Deadbolt Locks

    Winnebago is recalling 2014-2015 Itasca and Winnebago motorhomes because deadbolt locks may become stuck, potentially trapping occupants inside the vehicle.

    Product
    ITASCA — ITASCA, WINNEBAGO SPIRIT, VISTA, BRAVE, MINNIE WINNIE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V318000·2013-07-22

    Winnebago Recalls 2011 Motorhomes Due to Incorrect Tire Labeling

    Winnebago is recalling 2011 Vista and Itasca Sunstar motorhomes because the Vehicle Certification Label lists incorrect tire inflation pressures and wheel rim sizes.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA VISTA, SUNSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V162000·2013-04-26

    Winnebago Recalls 2013-2014 Motorhomes Due to Awning Motor Defect

    Winnebago is recalling specific 2013-2014 motorhomes because an awning motor defect may cause the awning to unfurl unexpectedly, increasing the risk of injury or a crash.

    Product
    ITASCA — ITASCA, WINNEBAGO SUNSTAR, ACCESS, FORZA, SUNOVA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V057000·2012-02-16

    Winnebago and Itasca Motor Homes Recalled for Transmission Cable Defect

    Winnebago is recalling 2011-2013 motor homes because a transmission cable may break, causing the gear indicator to display incorrectly and increasing crash risk.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA VISTA, SIGHTSEER, ADVENTURER, SUNSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V122000·2010-03-25

    Winnebago Motorhomes Recalled for Ricon Lift Restraint Belt Defect

    Winnebago is recalling 2008-2009 Itasca and Winnebago motorhomes equipped with Ricon public use lifts because the restraint belt may not fully latch, allowing the lift to operate with an occupant on the platform.

    Product
    ITASCA — ITASCA, WINNEBAGO SUNSTAR, VISTA, VOYAGE, TOUR
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all Winnebago models