The Recall Desk

State

US Virgin Islands product recalls

73,570 recalls have nationwide distribution and so reach US Virgin Islands. 178 additional recalls listed US Virgin Islands specifically in their distribution scope.

What the numbers show

Total
178
Critical
12
Severe
39
Most recent
2026-10-21

Of the 178 recalls naming US Virgin Islands we have scored against our rubric, 12 (7%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 39 (22%) are Severe.

These figures cover only the 178 recalls whose distribution notice names US Virgin Islands specifically. The 73,570 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

27026–27050 of 73748

  • SevereNHTSA·20V692000·2020-11-10

    Ford Recalls Explorer, Taurus, and Edge for Drive Axle Bracket Failure

    Ford is recalling 2014-2016 Explorer, 2014-2015 Taurus, and 2014 Edge vehicles because a front drive axle bracket may fail, risking loss of park function or motive power.

    Product
    FORD — FORD EXPLORER, TAURUS, EDGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·21027·2020-11-10

    Sunjoy Oakmont LP Fire Pit Tables Recalled for Fire Hazard

    Sunjoy is recalling Oakmont LP fire pit tables sold at Big Lots because an incorrectly installed hose can melt and ignite, posing a fire hazard.

    Product
    Oakmont LP fire pit tables
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V694000·2020-11-10

    Land Rover Recalls 2019-2020 Discovery Models for Electrical Faults

    Jaguar Land Rover is recalling 2019-2020 Discovery vehicles because a loose battery ground stud may cause electrical power loss or vehicle shutdown while driving.

    Product
    LAND ROVER — LAND ROVER DISCOVERY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21025·2020-11-10

    Salsa Cutthroat Bicycles Recalled Due to Fork Crack Injury Hazard

    Quality Bicycle Products is recalling Salsa Cutthroat bicycles because the fork legs can crack or break, posing a fall hazard to riders.

    Product
    Salsa Cutthroat Bicycles and Forks
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21026·2020-11-10

    Arena Swim Snorkels Recalled by CPSC Due to Choking Hazard

    Arena North America is recalling specific swim snorkels because they can release material that poses a choking hazard. One report of a piece being inhaled has been received.

    Product
    Arena Swim Snorkels Pro II and Swim Snorkels II
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·20V691000·2020-11-10

    2021 Ford F-650 and F-750 Transmission Cooling Line Fire Risk Recall

    Ford is recalling certain 2021 F-650 and F-750 vehicles because the transmission oil cooler line may contact the air conditioning compressor pulley, potentially causing a transmission fluid leak that could lead to an engine compartment fire.

    Product
    FORD — FORD F-650, F-750
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21029·2020-11-10

    Wintergreen Essential Oil Recalled for Non-Child-Resistant Packaging

    Bolek's Craft Supplys is recalling Crafty Bubbles Wintergreen Essential Oil because the bottles do not meet child-resistant packaging requirements, posing a poisoning risk to young children.

    Product
    Crafty Bubbles Wintergreen Essential Oil
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·20V690000·2020-11-09

    Thomas Built Buses Minotour Recalled for Wheelchair Lift Safety Defect

    Daimler Trucks North America is recalling 2008-2021 Thomas Built Buses Minotour school buses because the wheelchair lift may allow the vehicle to move, increasing injury risk.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES MINOTOUR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V689000·2020-11-06

    Autocar Xpeditor and Legend suspension bolts may fail and disconnect

    Autocar is recalling 2020-2021 Xpeditor and Legend vehicles because transverse torque rod mounting bolts may not be properly tightened. If bolts fail and disconnect, vehicles could lose suspension control, increasing crash risk.

    Product
    AUTOCAR — AUTOCAR LEGEND, XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20E083000·2020-11-06

    First Light Recalls Illuminated School Bus Stop Signs Due to Seal Defect

    First Light Safety Products is recalling illuminated school bus stop signs sold for specific bus models between April and October 2020. A defective weather seal may allow contaminants to enter, potentially causing electrical shorts and rendering the signs inoperable.

    Product
    EQUIPMENT recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V687000·2020-11-06

    2020-2021 Autocar Xpeditor ground cable may cause engine stall

    Certain 2020-2021 Autocar Xpeditor vehicles with X12N engines may have a ground cable that is too short and could fail, causing engine stall without restart capability. Autocar will replace the cable free of charge.

    Product
    AUTOCAR — AUTOCAR XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V683000·2020-11-05

    Land Rover Recalls 2020 Models Due to Electrical Fire Risk

    Jaguar Land Rover is recalling 2020 Discovery Sport and Range Rover Evoque MHEV vehicles because an electrical short-circuit could cause a fire.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER EVOQUE, DISCOVERY SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V686000·2020-11-05

    Freightliner Recalls Econic SD Trucks for Electrical Fire Risk

    Daimler Trucks North America is recalling 2019-2021 Freightliner Econic SD vehicles because damaged electrical cables may cause a fire or engine stall.

    Product
    FREIGHTLINER — FREIGHTLINER ECONIC SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V684000·2020-11-05

    2020 Chevrolet Silverado 1500 Overcured Tire Recall May Increase Crash Risk

    General Motors is recalling certain 2020 Chevrolet Silverado 1500 vehicles with overcured Continental tires that may experience sudden air loss or tread separation, increasing crash risk.

    Product
    GMC — GMC, CHEVROLET, BUICK ACADIA, TRAVERSE, ENCLAVE, XT5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V685000·2020-11-05

    Nissan Recalls 2020 Altima Vehicles Due to Over-Cured Tires

    Nissan is recalling 2,214 2020 Altima S vehicles because specific Continental tires may be over-cured, increasing the risk of a crash.

    Product
    NISSAN — NISSAN ALTIMA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V682000·2020-11-04

    Toyota and Lexus Recall Vehicles for Fuel Pump Failure Risk

    Toyota is recalling over 1.5 million vehicles because a fuel pump defect may cause the engine to stall while driving, increasing crash risk.

    Product
    LEXUS — LEXUS, TOYOTA RX350, LC500, LS500, LS HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0290-2021·2020-11-04

    GORE TAG CONFORMABLE Thoracic Stent Graft Recall for Deployment Issue

    W L Gore is recalling GORE TAG CONFORMABLE Thoracic Stent Grafts because a secondary deployment fiber attachment prevented completion of deployment via the access hatch.

    Product
    GORE TAG CONFORMABLE Thoracic Stent Graft with ACTIVE CONTROL System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0054-2021·2020-11-04

    Bausch Health Recalls Subpotent Hydrocortisone Butyrate Cream

    Bausch Health is recalling 35,424 tubes of Hydrocortisone butyrate Cream, 0.1%, because the product was found to be subpotent.

    Product
    Hydrocortisone butyrate Cream, 0.1%, 15-gram tubes, Rx Only, Manufactured for Oceanside Pharmaceuticals a division of Valeant Pharmaceuticals North America LLC Bridgewater, NJ 08807 USA, By: Ferndale Laboratories, Inc. Ferndale, MI 48220, NDC 68682-270-15
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V681000·2020-11-04

    Volvo Recalls S60 and S80 Vehicles Due to Air Bag Inflator Defect

    Volvo is recalling 2001-2003 S60 and S80 vehicles because the driver-side air bag inflator may rupture, sending metal fragments into the vehicle.

    Product
    VOLVO — VOLVO S60, S80
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V678000·2020-11-04

    Certain 2020-2021 BMW X5, X6, X7 models: suspension weld separation

    Certain 2020-2021 BMW X5, X6, X7, and related models have a front axle support weld that may separate, potentially affecting vehicle handling and control and increasing crash risk.

    Product
    BMW — BMW X6 M, X5, X6, X7
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0286-2021·2020-11-04

    Boston Scientific Recalls Hurricane RX Biliary Balloon Catheters Due to Detachment Risk

    Boston Scientific is recalling Hurricane RX Biliary Balloon Dilatation Catheters because the black sheath may detach from the shaft. The recall covers 15,062 units in the US and 12,930 internationally.

    Product
    Hurricane RX Biliary Balloon Dilatation Catheter Catalog REF No. M00545890; M00545900; M00545910; M00545920; M00545930; M00545940; M00545950; M00545960 The device is a double lumen catheter with a balloon mounted at the distal tip. Dilatation balloon catheters are used to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0285-2021·2020-11-04

    Philips Recalls Sterilizable Defibrillator Paddles Due to Undetected Failure Mode

    Philips is recalling 2,202 sterilizable defibrillator paddles because standard periodic checks may fail to detect a specific failure mode in switchless internal models.

    Product
    Philips Sterilizable Defibrillator Paddles, Switchless Internal Paddles, Model Numbers M1741A, M1742A, M1743A, M1744A - Product Usage: used in pairs to transmit a controlled electrical shock from an external defibrillator directly to the exposed heart muscle of a post-pubescent…
    Category
    Medical Device
    Distribution
    Distributed nationwide