22551–22575 of 73501

  • HighNHTSA·21V969000·2021-12-14

    Spartan K3 RV Chassis Models Recalled for Fuel System Defect

    Shyft Group is recalling 2020-2023 Spartan K3 RV chassis vehicles because fuel tubes may fatigue and crack, creating a potential fuel leak and fire risk. Dealers will install vibration isolators or replace fuel tubes at no cost.

    Product
    SPARTAN — SPARTAN K3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V961000·2021-12-13

    Mercedes-Benz Recalls Vehicles Due to Fuel Leak Fire Risk

    Mercedes-Benz is recalling specific gasoline-engine vehicles because trapped particles may cause a fuel leak, increasing the risk of a fire.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG G63, GLB 250, AMG A35, AMG C63
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V962000·2021-12-13

    Sutphen Recalls 2016-2020 Fire Trucks Due to Fuel Leak Risk

    Sutphen is recalling 2016-2020 fire trucks because fuel tubes may crack, causing high-pressure leaks that increase fire risk.

    Product
    SUTPHEN — SUTPHEN FIRE TRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V963000·2021-12-13

    2022 Toyota 4Runner recalled for inoperable high beam after fog light installation

    Southeast Toyota Distributors is recalling certain 2022 Toyota 4Runner vehicles because the driver's side high beam may become inoperable after installation of accessory fog lights. This reduces visibility and increases crash risk.

    Product
    TOYOTA — TOYOTA 4RUNNER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V966000·2021-12-13

    Autocar Xpeditor GPS Module Mounting Defect May Interfere With Brakes

    Autocar is recalling certain 2021-2022 Xpeditor vehicles because the GPS module may be improperly mounted and could come loose, potentially interfering with brake and throttle pedals.

    Product
    AUTOCAR — AUTOCAR XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V965000·2021-12-13

    Western Star and Freightliner Trucks Fuel Tubes May Crack, Fire Risk

    Fuel tubes in certain 2019–2022 Western Star, Freightliner, and FCCC trucks may crack, causing high-pressure fuel leaks that could ignite. DTNA is offering free replacement of fuel tubes and installation of vibration isolators.

    Product
    WESTERN STAR — WESTERN STAR, FREIGHTLINER, FCCC 4700, 114SD, 49X, 47X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V964000·2021-12-13

    Seagrave Fire Trucks Recalled for Fuel Tube Cracking and Fire Risk

    Seagrave is recalling 2019-2021 fire trucks with Cummins X12 engines because fuel tubes may crack, causing high-pressure leaks and fire risks.

    Product
    SEAGRAVE — SEAGRAVE CAPITAL, ATTACKER, MARAUDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V960000·2021-12-10

    KME Predator Fire Risk Recall Due to Fuel Tube Cracking

    KME is recalling 2020-2022 Predator and Severe Service vehicles because fuel tubes may crack, causing high-pressure leaks that increase fire risk.

    Product
    KME — KME PREDATOR SS, PREDATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22029·2021-12-10

    Target Recalls Decorative Mailbox Due to Laceration Hazard

    Target is recalling approximately 174,300 Letters to Santa Mailboxes because the mail slot can be sharp, posing a laceration hazard. Target has received seven reports of lacerations, three of which required medical attention.

    Product
    Letters to Santa Mailbox
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V954000·2021-12-09

    Subaru Recalls 2020 Ascent Vehicles for Steering Tie Rod Defect

    Subaru is recalling 2020 Ascent vehicles because front tie rod ends may not fit properly, potentially causing loss of steering control and increasing crash risk.

    Product
    SUBARU — SUBARU ASCENT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V953000·2021-12-09

    Mack Trucks Recalls TerraPro Models Due to Parking Brake Release Risk

    Mack Trucks is recalling certain TerraPro vehicles because a brake control valve air leak can cause the parking brake to release unexpectedly, increasing the risk of a crash.

    Product
    MACK — MACK TERRAPRO (MRU), TE, MRU, TERRAPRO (TE)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V952000·2021-12-09

    E-One Recalls Fire Trucks Due to Fuel Tube Cracking Risk

    E-One is recalling specific 2019-2021 Quest II, Typhoon, and Cyclone models because fuel tubes may crack, causing high-pressure leaks and fire risks.

    Product
    E-ONE — E-ONE QUEST II, TYPHOON, CYCLONE II, CYCLONE N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V950000·2021-12-09

    2021 Jeep Grand Cherokee L Inoperable Headlight Software Defect Recall

    Certain 2021 Jeep Grand Cherokee L vehicles may have inoperable headlights due to a smart lighting module software defect. This reduces visibility and increases the risk of crashes.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V949000·2021-12-09

    2021 Jeep Wrangler 4XE Recalled for Odometer Display Failure

    Chrysler is recalling 2021 Jeep Wrangler 4XE vehicles because the odometer stops displaying mileage after 13,342 miles, potentially delaying critical safety maintenance.

    Product
    JEEP — JEEP WRANGLER 4XE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V958000·2021-12-09

    2022 Nissan Frontier left-rear seat belt bracket bolts loose

    Certain 2022 Nissan Frontier vehicles have seat belt bracket mounting bolts on the left-rear seat that may have been incorrectly tightened. In a crash, a loose bracket may break, causing loss of seat belt restraint and increased injury risk.

    Product
    NISSAN — NISSAN FRONTIER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V957000·2021-12-09

    2021 Nissan Rogue recalled for fuel pump failure and engine stall risk

    Nissan is recalling approximately 24,793 2021 Rogue vehicles due to abnormal wear in the fuel pump that may cause overheating, failure, and engine stall, increasing crash risk.

    Product
    NISSAN — NISSAN ROGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V951000·2021-12-09

    Prevost Recalls 2020-2022 X3 Buses Due to Loose Ceiling Panel

    Prevost is recalling 2020-2022 X3 Commuter and X3 Coach buses because the front ceiling panel may fall, posing a crash or injury risk.

    Product
    PREVOST — PREVOST X3 COM, X3 COACH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V956000·2021-12-09

    Autocar Xpeditor and Legend fuel tubes may crack, risking fire

    Autocar is recalling 2019-2022 Xpeditor and 2020-2022 Legend vehicles. Fuel tubes may crack, causing a high-pressure leak that could ignite in the presence of a fire source.

    Product
    AUTOCAR — AUTOCAR XPEDITOR, LEGEND
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0230-2022·2021-12-08

    Jumbo Yellow Onions Recalled for Possible Salmonella Contamination

    Onions 52 is recalling 40-pound cartons of Jumbo Yellow Onions imported from Chihuahua, Mexico, due to possible contamination with Salmonella Oranienburg. The recall is voluntary and covers products distributed nationwide and in select regions.

    Product
    40# (LB) Ctn (box) Jumbo Yellow Onions, Product of Mexico - Label Carzalia Valley Produce, Distributed by Carzalia Valley Produce, Columbus, NM. UPC 00815222010023 Imported from Chihuahua, Mexico, sourced from ProSource and shipped from July 1, 2021 through August 25, 2021.…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0265-2022·2021-12-08

    Pfizer 5% Dextrose Injection Recalled for Potential Bag Leakage

    Pfizer is recalling one lot of 5% Dextrose Injection (50 mL ADD-Vantage Units) due to lack of sterility assurance; the bags have the potential to leak. This is a Class II recall affecting 765 bags distributed nationwide.

    Product
    DEXTROSE — DEXTROSE (DEXTROSE MONOHYDRATE)
    Category
    Drug
    Distribution
    Distributed nationwide