The Recall Desk

State

Florida product recalls

72,986 recalls have nationwide distribution and so reach Florida. 12,823 additional recalls listed Florida specifically in their distribution scope.

What the numbers show

Total
12,823
Critical
1,765
Severe
2,977
Most recent
2026-09-25

Of the 12,823 recalls naming Florida we have scored against our rubric, 1,765 (14%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,977 (23%) are Severe.

These figures cover only the 12,823 recalls whose distribution notice names Florida specifically. The 72,986 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

6976–7000 of 85809

  • SevereUSDA FSIS·021-2025·2025-06-12

    Starway Recalls Ineligible Frozen Fish Balls Imported From Vietnam

    Starway International Group is recalling approximately 9,513 pounds of frozen fish balls imported from Vietnam because the producing establishment is not eligible to export to the US.

    Product
    Starway International Group LLC Recalls Ineligible Frozen Siluriformes Fish Ball Products Imported From Vietnam
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V391000·2025-06-12

    Honda and Acura brake pedal pivot pins may not be secured

    Honda is recalling certain Acura TLX, Acura MDX and Honda Pilot vehicles because the brake pedal pivot pin was not secured properly, which can shift the pedal out of position.

    Product
    ACURA — ACURA, HONDA TLX, MDX, PILOT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V392000·2025-06-12

    Volvo electric and hybrid models can lose braking in one-pedal mode

    Volvo is recalling certain electric and plug-in hybrid models because the vehicle may lose brake function while coasting downhill in "B" mode or One Pedal Drive. Owners are told not to use those modes until repaired.

    Product
    VOLVO — VOLVO XC60PHEV, EC40, EX40, XC90PHEV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V390000·2025-06-12

    Chevrolet Silverado medium duty brake pressure switches may short and overheat

    GM is recalling certain 2019-2024 Chevrolet Silverado Medium Duty trucks because the brake pressure sensor may leak fluid into the switch and short circuit. Owners are told to park outside.

    Product
    CHEVROLET — CHEVROLET SILVERADO 4500, SILVERADO 6500, 6500, duplicate SILVERADO 5500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·25336·2025-06-12

    Bugaboo Giraffe Highchairs Recalled for Fall Hazard Risk

    Bugaboo North America is recalling about 18,280 Giraffe highchairs because the legs can detach from the frame if screws are not properly tightened during assembly, posing a risk of serious injury or death. The company has received 22 reports of leg detachment, including 13 reports of minor injuries.

    Product
    Giraffe highchairs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·25338·2025-06-12

    Anker PowerCore 10000 Power Banks Model A1263 Recalled for Fire and Burn Hazards

    Approximately 1,158,000 Anker PowerCore 10000 power banks (model A1263) are recalled because their lithium-ion batteries can overheat, creating fire and burn hazards. Anker has received 19 reports of fires and explosions, including property damage totaling over $60,700.

    Product
    Anker PowerCore 10000 power banks (model A1263 only)
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·25334·2025-06-12

    RYOBI 40V 24-Inch Cordless Hedge Trimmers Recalled for Laceration Hazard

    TI Outdoor Power Equipment is recalling about 113,000 RYOBI 40V 24-inch cordless hedge trimmers because the blade can unexpectedly activate from pressing only one control, causing lacerations. Consumers should stop using the trimmer and return it for a free replacement.

    Product
    RYOBI 40V 24-Inch Cordless Hedge Trimmers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1814-2025·2025-06-11

    Adult Manual Resuscitator with Medium Adult Mask recalled nationwide

    SunMed Holdings is recalling 11,358 Adult Manual Resuscitators because the filter may be incorrectly attached to the patient port instead of the exhalation port, risking interruption or delay in patient resuscitation that could cause serious harm or death.

    Product
    Adult Manual Resuscitator with Medium Adult Mask, Bag REservoir, Filter, Manometer and 7 ft Oxygen Tubing, REF CPRM1116F
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·H-0005-2025·2025-06-11

    Greenwise Pear Kiwi Spinach Pea Baby Food Pouches Recalled for Heavy Metals

    Publix Super Markets is recalling Greenwise Pear Kiwi Spinach & Pea Baby Food Pouches due to elevated levels of lead, cadmium, and arsenic. The product was distributed across eight southeastern states.

    Product
    Greenwise Pear Kiwi Spinach & Pea Baby Food Pouch. Net Wt 4 oz. (113g). Stage 2 6 months+, Best if" date of 11/01/2025. Packed in 14 pouches per case, 4 oz per pouch. Distributed by Publix Super Markets, Inc. 3300 Publix Corporate Parkway Lakeland, FL 33881.
    Category
    Food
    Distribution
    8 states
  • SevereFDA (Devices)·Z-1811-2025·2025-06-11

    Medline Craniotomy Kits with Defective Codman Disposable Perforators Recalled

    Medline is recalling multiple craniotomy kits containing Codman Disposable Perforators due to inadequate welds that may cause the perforators to break or separate during use.

    Product
    Medline Kits containing Codman Disposable Perforator 14 mm: 1. CRANI ACCESSORY PACK SKU DYNJ59270 2. CRANI PACK-LF SKU DYNJ44805M 3. CRANIOTOMY SKU CDS982719V CDS982719W DYNJ904168F DYNJ908404B DYNJ908723A DYNJ908723C 4. CRANIOTOMY #IMF 56646-LF SKU DYN
    Category
    Medical Device
    Distribution
    13 states
  • SevereFDA (Devices)·Z-1809-2025·2025-06-11

    Medline Surgical Kits with Codman Disposable Perforator recalled

    Medline surgical kits containing Codman Disposable Perforators are being recalled because certain lots have inadequate welds that may cause the perforator to break or separate during use.

    Product
    Medline Kits containing Codman Disposable Perforator 14 mm: 1. CRANI ADD A PACK, SKU DYNJ30926O 2. CRANIOTOMY, SKU CDS983611N 3. CRANIOTOMY CDS, SKU CDS983467J 4. CRANIOTOMY PACK, SKU DYNJ85807A, DYNJ85927 5. MAJOR CRANIOTOMY PACK, SKU DYNJ82007A
    Category
    Medical Device
    Distribution
    13 states
  • SevereFDA (Devices)·Z-1810-2025·2025-06-11

    Medline Craniotomy Kits with Defective Codman Disposable Perforators

    Medline is recalling craniotomy kits containing Codman Disposable Perforators with inadequate welds that may break or separate during use.

    Product
    Medline Kits containing Codman Disposable Perforator 14 mm: CRANIOTOMY, SKU DYNJ35349C
    Category
    Medical Device
    Distribution
    13 states
  • SevereFDA (Food)·H-0006-2025·2025-06-11

    Cucumbers from Pennrose Farms recalled for potential Salmonella contamination

    Pennrose Farms is recalling cucumbers due to potential Salmonella contamination. The recall affects 5-lb mesh bags distributed to FL, NJ, GA, IL, and OH.

    Product
    Cucumbers Pennrose Farms, Net Wt. 5lbs(2.26kg) Mesh bag, Distributed by PennRose Farms, LLC Welington, FL 33414, UPC code 841214101714
    Category
    Food
    Distribution
    5 states
  • SevereFDA (Drugs)·D-0456-2025·2025-06-11

    Fluoxetine Tablets 20 mg Recalled for N-Nitroso Impurity

    Torrent Pharma Inc. is recalling Fluoxetine Tablets, USP, 20 mg in a 28-count carton due to the presence of N-Nitroso Fluoxetine exceeding the interim acceptable intake limit.

    Product
    FLUOXETINE — FLUOXETINE (FLUOXETINE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1886-2025·2025-06-11

    Palindrome Precision HSI Chronic Hemodialysis Catheter Sport Pack Recalled

    Mozarc Medical is recalling Palindrome Precision HSI Chronic Hemodialysis Catheter Sport Packs due to a potential breach of sterile barrier packaging that could compromise the catheter's sterility.

    Product
    Palindrome Precision HSI Chronic Hemodialysis Catheter Sport Pack. Radiopaque urethane catheter.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1895-2025·2025-06-11

    Signature Laparoscopic Debakey Grasper Instruments Recalled for Insulation Defect

    Silex Medical is recalling 8 units of Signature Laparoscopic Debakey Grasper instruments (Model 5862100) due to incomplete insulation on the shaft near the rotator wheel, which could expose the user or patient to electrical contact.

    Product
    Signature Laparoscopic Instruments, Debakey Grasper with Rotating Shaft and Monopolar Electrosurgical Footswitch Connector. Model/REF Number: 5862100.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1910-2025·2025-06-11

    ChannelCheck Convenience Pack Pre-filled Water Syringes Recalled

    Healthmark Industries is recalling ChannelCheck Convenience Pack Pre-filled Water Syringes (Models UCC-222CP and UCC-222-ESP) because contamination was found in duodenoscope samples linked to the syringes, which were improperly used outside their intended purpose.

    Product
    ChannelCheck Convenience Pack, Model Numbers UCC-222CP and UCC-222-ESP (Sample)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1894-2025·2025-06-11

    Signature Laparoscopic Allis Clamp Grasper with Rotating Shaft Recalled

    Silex Medical is recalling the Signature Laparoscopic Instruments Allis Clamp Grasper due to incomplete insulation on the shaft, leaving an exposed area that could pose an electrical hazard during surgical procedures.

    Product
    Signature Laparoscopic Instruments, Allis Clamp Grasper with Rotating Shaft and Monopolar Electrosurgical Footswitch Connector. Model/REF Number: 5862030.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1900-2025·2025-06-11

    Signature Laparoscopic Atraumatic Grasper Insulation Defect Recall

    Silex Medical is recalling Signature Laparoscopic Instruments (Model 5881033) because insulation on the shaft does not fully extend to the proximal end, leaving an exposed area near the rotator wheel.

    Product
    Signature Laparoscopic Instruments, 20mm Atraumatic Grasper with Rotating Shaft and Monopolar Electrosurgical Footswitch Connector. Model/REF Number: 5881033.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1911-2025·2025-06-11

    Olympus EVIS EXERA III Duodenovideoscope TJF-Q190V Contamination Risk

    Olympus is recalling the EVIS EXERA III Duodenovideoscope Model TJF-Q190V due to post-market data showing higher microbial contamination when manual cleaning is delayed beyond one hour after patient use.

    Product
    Olympus EVIS EXERA III Duodenovideoscope. Model Number: TJF-Q190V
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0928-2025·2025-06-11

    GNC Women's 30+ Vitapak recalled due to undeclared fish allergen

    GNC Holdings LLC is recalling GNC Women's 30+ Vitapak due to undeclared fish allergen (parvalbumin). The product was distributed across multiple states.

    Product
    GNC Women's 30+ Vitapak, Carton of 30 Sachets. Each sachet contains four tablets and a capsule. Paper-board carton that measures 10.25 width x 3.56 height x 3.15 depth containing 30 sachets of 3 width x 2.75 height with tear notch. 15 Cartons per Case
    Category
    Food
    Distribution
    48 states
  • HighNHTSA·25V368000·2025-06-11

    Nova Bus turn signal indicator lights may remain solidly illuminated

    Nova Bus is recalling certain 2022-2023 LFS buses because a digital display firmware error may leave the instrument panel turn signal indicators solidly lit, failing FMVSS 108.

    Product
    NOVA BUS — NOVA BUS LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1893-2025·2025-06-11

    Signature Laparoscopic Dolphin Nose Grasper Instrument Insulation Defect

    Silex Medical is recalling 2 units of a Signature Laparoscopic Instruments Dolphin Nose Grasper with Rotating Shaft due to incomplete insulation on the shaft, leaving an exposed area near the rotator wheel.

    Product
    Signature Laparoscopic Instruments, Dolphin Nose Grasper with Rotating Shaft and Monopolar Electrosurgical Footswitch Connector. Model/REF Number: 5860020.
    Category
    Medical Device
    Distribution
    Distributed nationwide