The Recall Desk

State

Colorado product recalls

73,187 recalls have nationwide distribution and so reach Colorado. 6,945 additional recalls listed Colorado specifically in their distribution scope.

What the numbers show

Total
6,945
Critical
1,218
Severe
1,510
Most recent
2026-10-02

Of the 6,945 recalls naming Colorado we have scored against our rubric, 1,218 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,510 (22%) are Severe.

These figures cover only the 6,945 recalls whose distribution notice names Colorado specifically. The 73,187 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

11626–11650 of 80132

  • HighNHTSA·24V448000·2024-06-17

    Micro Bird Recalls G5 School Buses Due to Seat Attachment Defect

    Micro Bird is recalling 2011-2025 G5 school buses because certain seats may be improperly attached, increasing injury risk in a crash.

    Product
    MICRO BIRD — MICRO BIRD G5 SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V450000·2024-06-17

    2024 Land Rover Range Rover oil filter housing can crack and leak

    Jaguar Land Rover is recalling certain 2023–2024 Defender and 2024 Discovery, Range Rover, Range Rover Sport, and Range Rover Velar vehicles because the oil filter housing can crack and leak oil into the engine compartment, increasing the risk of fire.

    Product
    LAND ROVER — LAND ROVER DEFENDER, RANGE ROVER VELAR, DISCOVERY, RANGE ROVER SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V446000·2024-06-14

    Mercedes-Benz Recalls C 300 Vehicles Due to Wiring Fire Risk

    Mercedes-Benz is recalling 2022-2023 C 300 vehicles because an improperly tightened bolt on the pre-fuse box wire could cause overheating, leading to fire or loss of drive power.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ C 300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V442000·2024-06-14

    2023 Toyota Crown Rearview and Frontview Cameras May Separate

    Toyota is recalling certain 2023 Crown vehicles with defective rearview and frontview cameras that may separate and allow water infiltration, potentially failing to display images and reducing driver visibility.

    Product
    TOYOTA — TOYOTA CROWN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V441000·2024-06-14

    Thor Motor Coach Motorcoaches: Emergency Exit Window Obstruction Recall

    Thor Motor Coach is recalling 2023-2024 Magnitude and Omni motorcoaches because the emergency exit window can become blocked when the outside griddle is in use, potentially delaying evacuation during an emergency.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH MAGNITUDE, OMNI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V440000·2024-06-14

    2024 Ford Escape Adaptive Cruise Control Radar Misalignment

    Ford is recalling 2023-2024 Escape vehicles with adaptive cruise control due to misaligned radar modules. The misalignment can cause unexpected braking and loss of safety system function, increasing crash risk.

    Product
    FORD — FORD ESCAPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V445000·2024-06-14

    Mercedes-Benz transmission wiring harness recalled for fire risk

    Mercedes-Benz USA is recalling certain 2019-2025 CLS 53, E 53, GT 43, and GT 53 models due to transmission wiring harness defects that may cause corrosion and electrical short-circuits, increasing fire risk. Dealers will replace the harness free of charge.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG GT53, AMG CLS53, AMG E53, AMG GT43
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V443000·2024-06-14

    Ford Recalls 2021 F-150 Trucks Due to Disabled Reverse Lights

    Ford is recalling 2021 F-150 trucks with Onboard Scales because a software update may have disabled the reverse lights, increasing crash risk.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalCPSC·24265·2024-06-13

    Magnetic Chess Games Recalled for High-Powered Magnet Ingestion Hazard

    About 2,600 magnetic chess games with 20 magnet pieces sold on Temu.com from December 2023 through February 2024 are recalled because the magnets violate federal toy magnet regulations and pose a serious ingestion hazard.

    Product
    1 Set Puzzle "Magnetic", "Magnetism", or "Magnetism Intelligence Strategy Game" Magnetic Battle Chess Games
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·24262·2024-06-13

    Southern Telecom Recalls Lomi Roll-On Waxing Kits for Fire and Shock Hazards

    Southern Telecom is recalling about 19,500 Lomi Roll-On Waxing Kits because the power cord can overheat and short circuit, creating fire, burn, and electrical shock hazards. Two consumers suffered burns and one incident of property damage has been reported.

    Product
    Lomi Roll-On Waxing Kits
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V437000·2024-06-13

    Ram 1500 Recall: Rearview Camera Wiring Harness Defect

    Chrysler is recalling one 2022 Ram 1500 Classic because a wiring harness short may prevent the rearview camera from displaying, increasing crash risk.

    Product
    RAM — RAM 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24260·2024-06-13

    Daikin Air Conditioning and Heat Pump Units Recalled for Fire Hazard

    Daikin Comfort Technologies Manufacturing is recalling about 12,100 Amana, Daikin, and Goodman branded air conditioning and heat pump packaged units due to incorrect electrical ratings on the serial plate that could lead to improper wiring and fire risk.

    Product
    Amana, Daikin, and Goodman branded air conditioning and heat pump packaged units
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V434000·2024-06-13

    2023 Jeep Grand Cherokee Second-Row Seat Belt Fastener Recall

    Certain 2023 Jeep Grand Cherokee vehicles have a loose second-row seat belt buckle bolt that may not properly restrain occupants during a crash. Dealers will inspect and tighten the bolt free of charge.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V439000·2024-06-13

    Altec Aerial Devices Recalled for Defective Exterior Lighting Wire Harness

    Altec is recalling 2023-2024 aerial devices and related truck-mounted equipment due to lighting wire harness overload that may prevent vehicle lights from illuminating, reducing visibility to other drivers and increasing the risk of crashes.

    Product
    ALTEC — ALTEC AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24264·2024-06-13

    Bambu Lab A1 3D Printers Recalled for Electric Shock and Fire Hazards

    Bambu Lab is recalling about 12,800 A1 3D printers sold between December 2023 and January 2024 due to damaged or bent heatbed cables that can short-circuit, spark, or burn through insulation, creating electric shock and fire risks. No injuries have been reported.

    Product
    Bambu Lab A1 3D printers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V435000·2024-06-13

    Jayco Recalls 2024 Jay Feather Travel Trailers Due to Spare Tire Placard Error

    Jayco is recalling 2024 Jay Feather travel trailers because a 14-inch spare tire was installed with a 15-inch tire placard, creating a risk of incorrect inflation and crashes.

    Product
    JAYCO TRAVEL TRAILER — JAYCO TRAVEL TRAILER JAY FEATHER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24263·2024-06-13

    Nap Queen Sleep Victoria Hybrid Mattresses Recalled for Fire Hazard

    Adven Group is recalling approximately 117,200 Nap Queen Sleep Victoria Hybrid Mattresses sold nationwide from February 2020 through October 2023 because they violate federal flammability regulations, posing a fire hazard.

    Product
    Nap Queen Sleep Victoria Hybrid Mattresses
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V436000·2024-06-13

    Radio software may disable rearview camera in multiple Chrysler vehicle models

    Certain 2021-2023 Chrysler, Jeep, Ram, and Dodge vehicles have defective radio software that may prevent the rearview camera from displaying, reducing driver visibility when backing up.

    Product
    JEEP — JEEP, CHRYSLER, RAM GRAND CHEROKEE, VOYAGER, GRAND WAGONEER, COMPASS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V432000·2024-06-13

    Airstream Recalls 2024 Interstates Due to Missing Water Heater Fuse

    Airstream is recalling 2024 Interstate motorhomes because a missing 12-volt fuse could allow the supply wire to overheat, increasing the risk of fire.

    Product
    AIRSTREAM — AIRSTREAM INTERSTATE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24266·2024-06-13

    Beaumont Plus ST Bicycles with Disc Brakes Recalled for Brake Failure Risk

    Retrospec is recalling about 530 Beaumont Plus ST bicycles with disc brakes because the front brake rotor and pads can become misaligned, potentially causing brake failure and crashes. No injuries have been reported.

    Product
    Beaumont Plus ST Bikes with disc brakes
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·24261·2024-06-13

    Black Diamond Neve Strap Crampons Recalled Due to Fall Hazard

    Black Diamond Equipment is recalling Neve Strap Crampons and Accessory Kits because screws connecting the heel cup to the crampon can loosen, causing the heel cup to detach and creating a fall hazard. The firm has received three reports of incidents but no injuries have been reported.

    Product
    Neve Strap Crampons and Accessory Kits
    Category
    Consumer Product
    Distribution
    Distributed nationwide