The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1926–1950 of 39703

  • CriticalFDA (Devices)·Z-0136-2026·2025-10-29

    Impella controllers recalled over purge pressure issues from retainer failures

    Abiomed is recalling Automated Impella Controllers over the potential for purge pressure issues caused by purge retainer failures, covering 9,177 distributed units.

    Product
    Automated Impella Controller (AIC) labeled as the following with corresponding Product Codes: 1. AIC w/Impella Connect for ECP, Product Code: 1000432. 2. Dbl optical, AIC Impella Connect, Phg US, Product Code: 1000201. 3. Impella Controller, Packaged, AU, Product Code…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·H-0125-2026·2025-10-29

    Penne salad kits recalled over Listeria in recalled pasta ingredient

    Albertsons Companies is recalling its store-made Smoked Mozzarella Penne Salad Kit because it contains a penne pasta ingredient recalled for Listeria monocytogenes.

    Product
    Smoked Mozzarella Penne Salad Kit, UPC 271876 #####. Product was made in-store with store generated scale label applied to the container. Sold under store banners Carrs-Safeway, Eagle, and Safeway in AK.
    Category
    Food
    Distribution
    15 states
  • CriticalFDA (Food)·H-0087-2026·2025-10-29

    Large mozzarella penne salads recalled over potential Listeria from supplier

    Giant Eagle is recalling 16 lbs of large Smoked Mozzarella Penne Salad after a recall notification from its supplier about potential Listeria contamination.

    Product
    Smoked Mozzarella Penne Salad-Large, Clam shell and Bowl, 9 lbs, Individual Unit, Keep Refrigerated, UPC 246512000000
    Category
    Food
    Distribution
    4 states
  • CriticalFDA (Food)·H-0090-2026·2025-10-29

    Bowtie pasta kits recalled over potential Listeria monocytogenes contamination

    Reser's Fine Foods is recalling 3,252 cases of Fresh Creative Foods Basil Pesto Bowtie Pasta Kit for potential contamination with Listeria monocytogenes.

    Product
    Fresh Creative Foods (FCF) item #404637 Basil Pesto Bowtie Pasta Kit Item V, UPC#13454 38053. Perishable/Refrigerated product. Net wt. 10.5625lbs. This kit contains 2/3lbs. sealed bags of affected Bowtie Pasta, and it is not sold directly to consumers.
    Category
    Food
    Distribution
    13 states
  • CriticalFDA (Food)·H-0094-2026·2025-10-29

    Basil pesto bowtie salad recalled over recalled pasta ingredient and Listeria

    Kroger is recalling 5,567.4 lbs of Basil Pesto Bowtie Pasta Salad because the store-made deli item contains a pasta ingredient recalled for potential Listeria monocytogenes.

    Product
    Basil Pesto Bowtie Pasta Salad, packaged in plastic containers with various weights, with UPC 217573-1XXXX (sold at deli service counters) or UPC 217573-2XXXX (sold as Grab-n-Go packages in deli departments), under the banners Kroger, Baker's, City Market, Dillons, Fred Meyer…
    Category
    Food
    Distribution
    28 states
  • SevereNHTSA·25V737000·2025-10-29

    Mazda CX-50 front suspension bolts may allow wheel detachment

    Mazda is recalling certain 2025 CX-50 and CX-50 Hybrid vehicles because the front suspension fastener bolts may not be tightened properly, which can result in suspension component or wheel detachment.

    Product
    MAZDA — MAZDA CX-50, CX-50 HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V735000·2025-10-27

    Tesla Cybertruck accessory light bar can loosen from the windshield

    Tesla is recalling certain 2024 Cybertruck vehicles fitted with a service-installed off-road light bar because an incorrect surface primer may allow the light bar to loosen and detach.

    Product
    TESLA — TESLA CYBERTRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·035-2025·2025-10-27

    E.A. Sween Recalls Pulled Pork Sandwiches Due to Plastic Contamination

    E.A. Sween Company is recalling approximately 127,887 pounds of pulled pork sandwiches that may contain pieces of plastic. The products were distributed nationwide.

    Product
    E.A. Sween Company — E.A. Sween Company Recalls Pulled Pork Sandwich Products Due to Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·034-2025·2025-10-25

    Hormel Foods recalls frozen ready-to-eat chicken for metal contamination

    Hormel Foods is recalling about 4.8 million pounds of frozen ready-to-eat chicken products that may contain metal pieces.

    Product
    Hormel Foods Corporation — Hormel Foods Corporation Recalls Ready-To-Eat Frozen Chicken Products Due to Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V729000·2025-10-24

    Ford moonroof wind deflectors can detach from the vehicle

    Ford is recalling certain 2021-2023 Expedition, Navigator, F-150 and Super Duty vehicles because the moonroof wind deflector clips may be inadequately attached, letting the deflector detach.

    Product
    FORD — FORD, LINCOLN F-150, EXPEDITION, NAVIGATOR, F-250 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V725000·2025-10-24

    Mercedes-Benz Recalls Sprinter 2500 Vehicles Due to Frame Defect

    Daimler Vans USA is recalling 2023-2024 Mercedes-Benz Sprinter 2500 vehicles because a frame member may not be reinforced properly, reducing third-row seat structural integrity.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SPRINTER 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V727000·2025-10-24

    Forest River toy hauler fresh water tank can detach when full

    Forest River is recalling certain 2021 XLR Toy Hauler travel trailers because the mounting brackets may be improperly located or secured, allowing the fresh water tank to detach when full.

    Product
    FOREST RIVER — FOREST RIVER XLR TOYHAULER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25E070000·2025-10-24

    Ford Recalls 10R80 Automatic Transmissions for Missing Bearing

    Ford is recalling specific 10R80 re-manufactured automatic transmissions used in 2017-2021 Ford and Lincoln vehicles because a missing T10 bearing may prevent the vehicle from holding the Park position.

    Product
    POWER TRAIN:AUTOMATIC TRANSMISSION recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·033-2025·2025-10-24

    LSI, Inc. Recalls BBQ Pork Jerky Due to Possible Metal Contamination

    LSI, Inc. is recalling BBQ pork jerky because pieces of metal were found in the product. No injuries have been reported, but consumers should not eat the product.

    Product
    LSI, Inc. — LSI, Inc. Recalls BBQ Pork Jerky Product Due To Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V721000·2025-10-23

    Ford Bronco front seat pivot bolts may be loose or dislodged

    Ford is recalling certain 2021-2023 Bronco vehicles because the front seats may have a loose or dislodged seat frame height-adjust pivot bolt, so the seat may not restrain an occupant in a crash.

    Product
    FORD — FORD BRONCO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26046·2025-10-23

    Curling irons recalled after 258 reports of the barrel detaching

    About 357,000 Bio Ionic one-inch long barrel curling irons are being recalled after 258 reports of the barrel snapping and detaching, including six minor burn injuries.

    Product
    Bio Ionic One-Inch-Long Barrel Curling Iron
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V723000·2025-10-23

    Honda CB1000SP gearshift pedal pivot bolt can loosen and detach

    Honda is recalling certain 2025 CB1000SP Hornet SP motorcycles because the pivot bolt on the gearshift pedal may loosen and detach, leaving the rider unable to change gear. This fails FMVSS 123.

    Product
    HONDA — HONDA CB1000SP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V724000·2025-10-23

    Wartech SpecialContainer Trailers Recalled for Brake Fitting Leak Risk

    Wartech is recalling 2022-2025 SpecialContainer trailers because an incorrect piping fitting may leak air, reducing brake pressure and increasing crash risk.

    Product
    WARTECH — WARTECH SPECIALCONTAINER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0057-2026·2025-10-22

    BF-P190 bronchovideoscopes recalled for clarified laser and coagulation instructions

    Olympus is recalling EVIS EXERA III Bronchovideoscope BF-P190 units for instructions-for-use updates on safe use with laser, argon plasma coagulation and high-frequency therapy equipment.

    Product
    EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-P190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0062-2026·2025-10-22

    BF-Q180-AC bronchovideoscopes recalled for updated laser and coagulation use instructions

    Olympus is recalling EVIS EXERA II Bronchovideoscope BF Type Q180-AC units for instructions-for-use updates on safe use with laser, argon plasma coagulation and high-frequency therapy equipment.

    Product
    EVIS EXERA II BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Q180-AC
    Category
    Medical Device
    Distribution
    Distributed nationwide