The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

4126–4150 of 39749

  • SevereNHTSA·24E065000·2024-08-05

    Mack Trucks Recalls Replacement Tie Rods With Defective Ball Studs

    Mack Trucks is recalling certain replacement tie rods equipped with USK ball studs that may break due to incorrect heat treatment, potentially causing loss of steering control.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V571000·2024-08-01

    2025 Freightliner Cascadia Front Axle Tie Rod Defect Recall

    Certain 2025 Freightliner and Western Star commercial trucks may have defective front axle tie rods that can fail and cause loss of steering control. Owners should contact DTNA at 800-745-8000 for free replacement.

    Product
    FREIGHTLINER — FREIGHTLINER, WESTERN STAR CASCADIA, 108SD, 47X, 114SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2409-2024·2024-07-31

    NIM Vital Nerve Monitoring Systems Recalled for False Negative Risk

    Medtronic Xomed is recalling NIM Vital Nerve Monitoring systems because they may fail to detect nerve damage or dysfunction. Approximately 7,804 units were distributed worldwide.

    Product
    NIM Vital Nerve Monitoring systems (all serial numbers manufactured) with NIM Vital System versions: v1.0.0, v1.1.1, v1.3.2, v1.4.3. NIM Vital Nerve Integrity Monitor with below product descriptions. 1. CONSOLE NIM4CM01 NIM 4.0, Model Number: NIM4CM01. 2. CONSOLE…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V568000·2024-07-31

    Jayco Recalls 2025 Entegra Cornerstone Motorhomes Due to Fire Risk

    Jayco is recalling 2025 Entegra Cornerstone motorhomes because inadequate fuse protection on chassis batteries increases the risk of a fire.

    Product
    ENTEGRA — ENTEGRA CORNERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalUSDA FSIS·023-2024-EXP·2024-07-30

    Boar's Head Expands Recall of Deli Meats Due to Listeria

    Boar's Head is recalling 7 million pounds of ready-to-eat meat and poultry products due to possible Listeria contamination linked to a multistate outbreak.

    Product
    Boar's Head Provisions Co., Inc. — Boar's Head Provisions Co. Expands Recall for Ready-To-Eat Meat and Poultry Products Due to Possible Listeria Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V566000·2024-07-30

    Tiffin motorhome chassis controller can blow a fuse shutting down engine

    Tiffin is recalling certain 2022-2025 Phaeton, Allegro Bus and Zephyr motorhomes because the PowerGlide chassis controller may have insufficient circuit protection, which can blow a fuse and shut down the engine.

    Product
    TIFFIN — TIFFIN PHAETON, ZEPHYR, ALLEGRO BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E063000·2024-07-30

    Mevotech Recalls Aftermarket Front Lower Control Arms Due to Design Flaw

    Mevotech is recalling specific aftermarket front lower control arms because a design flaw may cause the ball joint to separate, increasing crash risk.

    Product
    SUSPENSION:FRONT:CONTROL ARM:LOWER ARM recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V567000·2024-07-30

    Mack truck seat and belt anchorage bolts may be improperly tightened

    Mack is recalling certain 2024-2025 Anthem, Granite and Pinnacle vehicles with RollTek driver's seats because the seat pedestal and seat belt attachment may have been improperly tightened.

    Product
    MACK — MACK PINNACLE (PI/PN), ANTHEM (AN), PIONEER PR (4), GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalUSDA FSIS·023-2024·2024-07-26

    Boar's Head Recalls Deli Meats Due to Listeria Contamination

    Boar's Head Provisions is recalling liverwurst and other deli meats nationwide due to possible Listeria monocytogenes contamination linked to a multistate outbreak.

    Product
    Boar's Head Provisions Co., Inc. — Boar's Head Provisions Co. Recalls Ready-To-Eat Liverwurst And Other Deli Meat Products Due to Possible Listeria Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E062000·2024-07-26

    Meritor Recalls Replacement Tie Rods Due to Heat-Treatment Defect

    Meritor is recalling replacement tie rods with specific USK ball studs that may break due to incorrect heat treatment, risking loss of steering control.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·24321·2024-07-25

    Hover-1 Dynamo E-Scooters Recalled Due to Brake Failure Risk

    DGL Group is recalling about 4,200 Hover-1 Dynamo e-scooters sold on Walmart.com from November 2021 through July 2022 because the brakes can fail, creating a serious injury and crash hazard. The company has received 22 reports of brake failure resulting in seven injuries.

    Product
    Hover-1 Dynamo E-scooters
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·24315·2024-07-25

    Ophanie Large Pink Area Rugs Recalled for Fire Hazard

    Ophanie large pink area rugs sold on Amazon violate federal flammability regulations and pose a fire hazard. About 5,200 units sold from April through June 2024 are being recalled.

    Product
    Ophanie Large Pink Area Rugs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V556000·2024-07-25

    Second Navistar recall covers incorrectly heat treated tie rod ball studs

    A second Navistar recall covers certain 2025 International HV, HX, LT, MV and RH vehicles whose tie rod ball studs may have been incorrectly heat-treated. 573 units affected.

    Product
    INTERNATIONAL — INTERNATIONAL HX, LT, RH, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V559000·2024-07-25

    Nova Bus Recalls 2019-2021 LFS Models Due to Brake Chamber Defect

    Nova Bus is recalling 166 LFS and LFS Artic buses because a defective brake chamber may leak air, causing unexpected braking, overheating, or fire.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V558000·2024-07-25

    Nova Bus Recalls 2016-2019 LFS Models Due to Brake Chamber Defect

    Nova Bus is recalling 2016-2019 LFS and LFS Artic buses because a defective brake chamber may leak air, causing unexpected braking, overheating, or fire.

    Product
    NOVA BUS — NOVA BUS LFS ARTIC, LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2319-2024·2024-07-24

    Abiomed Impella CP with SmartAssist heart pump units recalled for failed inspection

    Abiomed is recalling 9 Impella CP with SmartAssist heart pump units that failed inspection and were inadvertently released. The devices were distributed in Florida, Massachusetts, Ohio, and Texas.

    Product
    Impella CP with SmartAssist, Product No.: 1000080 (REF 0048-0003). left heart support blood pump
    Category
    Medical Device
    Distribution
    4 states
  • CriticalFDA (Food)·F-1483-2024·2024-07-24

    Deluxe Roasted Salted Mixed Nuts recalled for undeclared peanut allergen

    DSD Merchandisers recalls Deluxe Roasted Salted Mixed Nuts (Item 99651) for undeclared peanut allergen, with distribution in six western states and a sell-by date of October 9, 2024. Consumers with peanut allergies should not consume this product.

    Product
    Deluxe Roasted Salted Mixed Nuts ITEM NUMBER 99651 UPC: 6-51433-99651-6 SELL BY: 10/09/2024
    Category
    Food
    Distribution
    6 states
  • SevereFDA (Drugs)·D-0609-2024·2024-07-24

    StellaLife VEGA Oral Care Spray Recalled for Bacillus Contamination

    StellaLife VEGA Oral Care spray bottles have been recalled due to contamination with multiple Bacillus species organisms. The FDA Class I recall affects 31,811 bottles distributed nationwide to physician offices.

    Product
    STELLALIFE VEGA ORAL CARE — STELLALIFE VEGA ORAL CARE (ARNICA, CALENDULA, CHAMOMILLA, ECHINACEA ANGUSTIFOLIA, ECHINACEA PURPUREA, HEPAR SULPH CALC, HYPERICUM, LGNATIA, RUTA, STAPHYSAGRIA)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0604-2024·2024-07-24

    Potassium Chloride Extended-Release Capsules Recalled for Failed Dissolution Specifications

    Glenmark Pharmaceuticals is recalling potassium chloride extended-release capsules (750 mg) nationwide due to failed dissolution specifications. Affected patients should contact their healthcare provider before making any changes to their medication.

    Product
    POTASSIUM CHLORIDE — POTASSIUM CHLORIDE (POTASSIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1479-2024·2024-07-24

    Greens products recalled for potential Listeria monocytogenes contamination

    Solata Food LLC is recalling multiple brands of greens products distributed in NY, NJ, and NH due to potential Listeria monocytogenes contamination. Affected products, totaling 4,382 lbs with expiration dates of June 20–24, 2024, should not be consumed.

    Product
    1. Greens Solata 5050; 6x10 clamshell; UPC: 850021494766 / 2. Greens Gaia Organic 5050; 6x10 clamshell; UPC: 850021494827 / 3. Greens Gaia Organic 50/50 blend; 8x45 clamshell; UPC: 850021494919 / 4. Greens Gaia Organic 50/50; 8x45 clamshell; UPC: 850021494957 / 5. Greens Full…
    Category
    Food
    Distribution
    3 states
  • SevereFDA (Devices)·Z-2322-2024·2024-07-24

    Volara System Blue Ventilator Adapter Module Handset Plug Disconnection

    Baxter Healthcare is recalling 350 units of the Volara System Blue Ventilator Adapter Module because the handset plug may disconnect from the nebulizer port, disrupting ventilator gas flow. Affected units were distributed nationwide and internationally.

    Product
    Volara System. Blue Ventilator Adapter Module. Intermittent positive pressure breathing device component.
    Category
    Medical Device
    Distribution
    Distributed nationwide