The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

11326–11350 of 15216

  • SevereNHTSA·15V172000·2015-03-24

    Ford Recalls 2013-2015 Lincoln MKT Vehicles Due to Fire Risk

    Ford is recalling specific 2013-2015 Lincoln MKT vehicles with limousine or hearse packages because a vacuum pump relay may overheat, increasing the risk of a vehicle fire.

    Product
    LINCOLN — LINCOLN MKT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V170000·2015-03-24

    Spartan Recalls 2011-2016 School Bus Chassis Due to Fire Risk

    Spartan Motors is recalling 2011-2016 school bus chassis because fuel system components may melt, causing engine stalls or vehicle fires.

    Product
    SPARTAN — SPARTAN SB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V171000·2015-03-24

    Ford Recalls 2011-2013 Explorers for Door Handle Spring Defect

    Ford is recalling 2011-2013 Explorers because an interior door handle spring may unseat, preventing the handle from returning to its stowed position. This could cause the door to unlatch in a side impact crash.

    Product
    FORD — FORD EXPLORER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V173000·2015-03-24

    KZ-RV Recalls 723 Recreational Vehicles Due to Failing Entry Step Rivets

    KZ-RV is recalling 723 recreational vehicles because a rivet on the quad entry steps may shear and fail, causing the steps to give and increasing the risk of personal injury.

    Product
    KZ-RV — KZ-RV GOLDRUSH DISCOVERY, GOLDRUSH, GOLDRUSH NUGGET, STONERIDGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V165000·2015-03-23

    Navistar Recalls 2015-2016 International Trucks Due to Brake Fire Risk

    Navistar is recalling 2015-2016 International and IC Bus vehicles because defective brake actuators may cause dragging, overheating, and wheel end fires.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS TRANSTAR, CE, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V168000·2015-03-23

    Navistar Recalls 2015 IC RE Transit Buses for Brake Hose Defect

    Navistar is recalling 2015 IC RE non-school Transit Buses because the front air brake hose may contact the tire, causing leaks and increased crash risk.

    Product
    IC BUS — IC BUS RECB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V166000·2015-03-23

    Navistar Recalls 2015-2016 IC School Buses for Brake Fire Risk

    Navistar is recalling specific 2015-2016 IC school buses because defective air brake actuators may cause dragging brakes and wheel end fires.

    Product
    IC BUS — IC BUS CASB, CESB, RESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V164000·2015-03-23

    GM Recalls 2013-2015 Chevrolet Malibu for Sunroof Pinch Hazard

    General Motors is recalling 2013-2015 Chevrolet Malibus because the sunroof switch may be pressed inadvertently, causing the roof to close unexpectedly and risk pinch injuries.

    Product
    CHEVROLET — CHEVROLET MALIBU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V159000·2015-03-20

    Charles Machine Recalls Ditch Witch T26 Trailers Due to Bearing Defect

    Charles Machine is recalling 2002-2015 Ditch Witch T26 trailers because incorrect wheel bearings may fail, causing the wheel to detach and increasing crash risk.

    Product
    CHARLES MACHINE — CHARLES MACHINE DITCH WITCH T26
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V160000·2015-03-20

    Forest River Recalls 2013-2014 Sabre Trailers Due to Brake Wiring Defect

    Forest River is recalling 2013-2014 Sabre travel trailers and fifth wheels because improperly routed brake wires may chafe, break, or short, increasing crash and fire risks.

    Product
    FOREST RIVER — FOREST RIVER SABRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V162000·2015-03-20

    GM Recalls 2015 Buick Encore and Chevrolet Trax for Tire Label Defect

    General Motors is recalling 2015 Buick Encore and Chevrolet Trax vehicles because tire placards lack rim size information, which may lead to incorrect rim replacement and increased crash risk.

    Product
    CHEVROLET — CHEVROLET, BUICK TRAX, ENCORE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V161000·2015-03-20

    Jerr-Dan Recalls 2010 Standard Duty Wreckers Due to Boom Drift Risk

    Jerr-Dan is recalling 50 model year 2010 Standard Duty Wreckers because the underlift boom may drift down during towing, increasing the risk of a crash.

    Product
    JERR-DAN — JERR-DAN STANDARD DUTY WRECKER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V156000·2015-03-18

    Forest River Recalls 2014 Palomino SolAire Trailers Due to Furnace Vent Defect

    Forest River is recalling 2014 Palomino SolAire trailers manufactured between July and August 2014 because they may lack an exterior furnace vent, posing risks of carbon monoxide poisoning and fire.

    Product
    FOREST RIVER — FOREST RIVER PALOMINO SOLAIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V157000·2015-03-18

    GM Recalls 2015 Chevrolet Colorado and GMC Canyon for Air Bag Defect

    General Motors is recalling 2015 Chevrolet Colorado and GMC Canyon vehicles because the driver's air bag inflator may be misaligned, posing a risk of injury during deployment.

    Product
    CHEVROLET — CHEVROLET, GMC COLORADO, CANYON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15E022000·2015-03-18

    Woodstock Stop Arms Recalled for Non-Compliant Border Width

    Woodstock Safety Mirror Co. is recalling specific Stop Arms because the border width is too narrow, reducing visibility and failing federal safety standards.

    Product
    EQUIPMENT recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V158000·2015-03-18

    Charles Machine Recalls Ditch Witch T18 Trailers Due to Wheel Lockup Risk

    Charles Machine is recalling 2013-2015 Ditch Witch T18 trailers because incorrect bearing pre-loads may cause wheels to lock up, increasing crash risk.

    Product
    CHARLES MACHINE — CHARLES MACHINE DITCH WITCH T18
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V154000·2015-03-17

    Hyundai Translead Recalls 2014-2015 Trailers Due to Brake Drag Risk

    Hyundai Translead is recalling 3,412 model year 2014-2015 trailers because improperly seated brake diaphragms may cause drag, potentially leading to wheel end fires.

    Product
    HYUNDAI TRANSLEAD — HYUNDAI TRANSLEAD CONVERTER DOLLY TRAILER, VAN TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V152000·2015-03-16

    Ducati Recalls Multistrada 1200 Motorcycles Due to Throttle Cable Defect

    Ducati is recalling 2010-2014 Multistrada 1200 motorcycles because a moving throttle cable sleeve may prevent the throttle from closing fully, increasing crash risk.

    Product
    DUCATI — DUCATI MULTISTRADA 1200
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V151000·2015-03-16

    Spartan Tool Sewer Jetter Trailer Hitch Weld Failure Recall

    Spartan Tool is recalling 2013-2014 Sewer Jetters because trailer hitch welds may fail, causing the trailer to detach from the tow vehicle.

    Product
    SPARTAN TOOL — SPARTAN TOOL SEWER JETTER 740, SEWER JETTER 758, SEWER JETTER 738
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V150000·2015-03-16

    Altec Recalls 2014 Aerial Devices Due to Counterbalance Valve Defect

    Altec is recalling 2014 Aerial Devices because a counterbalance valve may crack, causing hydraulic leaks and unintended boom movement that increases injury risk.

    Product
    ALTEC — ALTEC AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V149000·2015-03-16

    Newmar Recalls 2014-2015 Motor Homes Due to Wiper Blade Separation Risk

    Newmar is recalling 153 model year 2014-2015 motor homes because wiper blades may separate from the arms, reducing driver visibility and increasing crash risk.

    Product
    NEWMAR — NEWMAR ESSEX, LONDON AIRE, MOUNTAIN AIRE, KING AIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide