The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

4726–4750 of 7641

  • SevereNHTSA·16V177000·2016-03-29

    Terex Recalls 2011-2016 Aerial Devices Due to Inadequate Boom Tip Welds

    Terex is recalling 2011-2016 aerial devices because inadequate welds at the boom tip may cause the platform to tilt unexpectedly, increasing the risk of user injury.

    Product
    TEREX — TEREX AERIAL DEVICES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V173000·2016-03-25

    BMW Recalls 2016 7 Series Vehicles Due to Air Bag Control Module Defect

    BMW is recalling 6,110 model year 2016 740Li, 750Li, and 750Lxi vehicles because the air bag control module may reset, preventing air bags from deploying in a crash.

    Product
    BMW — BMW 750LI, 750LXI, 740LI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V171000·2016-03-24

    Volkswagen Recalls 2012-2014 Passat TDI Vehicles for Fire Risk

    Volkswagen is recalling 2012-2014 Passat TDI vehicles because water can corrode electrical connectors, causing a short that may lead to a fire.

    Product
    VOLKSWAGEN — VOLKSWAGEN PASSAT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V168000·2016-03-23

    Chrysler Recalls 2015-2016 Jeep and Dodge Vehicles for Brake Caliper Defect

    Chrysler is recalling 21,183 2015-2016 Jeep Grand Cherokee and Dodge Durango vehicles because the left front brake caliper may crack, increasing stopping distance and crash risk.

    Product
    DODGE — DODGE, JEEP DURANGO, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V169000·2016-03-23

    Porsche Recalls Cayenne Vehicles Due to Brake Pedal Pivot Pin Defect

    Porsche is recalling 2011-2016 Cayenne vehicles because a missing circlip may allow the brake pedal to dislodge, potentially preventing the driver from braking.

    Product
    PORSCHE — PORSCHE CAYENNE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V161000·2016-03-21

    Winnebago Winnie Drop Recalled for Carbon Monoxide Leak Risk

    Winnebago is recalling 2016 Winnie Drop trailers because the refrigerator compartment may not seal properly, allowing carbon monoxide to enter the cabin.

    Product
    WINNEBAGO — WINNEBAGO WINNIE DROP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V160000·2016-03-18

    GM Recalls 2014-2016 Chevrolet Caprice Police Pursuit for Steering Defect

    General Motors is recalling 2014-2016 Chevrolet Caprice Police Pursuit vehicles because corrosion may cause loss of electric power steering assist, increasing crash risk.

    Product
    CHEVROLET — CHEVROLET CAPRICE POLICE PURSUIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V157000·2016-03-17

    Rosenbauer Commander Recall for Brake Pedal Piston Corrosion

    Rosenbauer is recalling 2012-2015 Commander vehicles because brake pedal pistons may corrode, making brakes difficult to activate or causing them to drag.

    Product
    ROSENBAUER — ROSENBAUER COMMANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V155000·2016-03-16

    Winnebago Recalls 2015-2016 RVs for Improperly Torqued Hitch Bolts

    Winnebago is recalling certain 2015-2016 Adventurer and Itasca Suncruiser vehicles because hitch bolts were not properly torqued, which could cause the hitch to detach and increase crash risk.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA ADVENTURER, SUNCRUISER, COMMERCIAL VEHICLE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V149000·2016-03-11

    Nissan Recalls 2014 Rogue Vehicles for Fuel Pump Failure Risk

    Nissan is recalling 46,671 model year 2014 Rogue vehicles because a fuel pump defect may cause the vehicle to stall without warning, increasing the risk of a crash.

    Product
    NISSAN — NISSAN ROGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V151000·2016-03-11

    GM Recalls 2016 Chevrolet Malibus for Side Air Bag Weld Defect

    General Motors is recalling 2016 Chevrolet Malibus because side air bag weld studs may fracture, increasing injury risk during deployment.

    Product
    CHEVROLET — CHEVROLET MALIBU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V143000·2016-03-09

    Freightliner Recalls 2015-2016 Cascadia Trucks for Fire Risk

    Daimler Trucks is recalling 8,865 Freightliner Cascadia trucks due to a potential electrical fire risk in the air conditioning compressor.

    Product
    FREIGHTLINER — FREIGHTLINER CASCADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V144000·2016-03-09

    Van Hool Motor Coaches Recalled for Potential Seat Belt Anchor Separation

    Van Hool is recalling specific motor coaches because missing welds on seat brackets could allow the driver's seat belt anchorage to separate during a crash.

    Product
    VAN HOOL — VAN HOOL C2045, T2145, TD925, TX45
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V142000·2016-03-08

    Setra Recalls 2005-2009 S417 Coaches Due to Control Arm Defect

    Setra is recalling 2005-2009 S417 coaches because a cracked control arm tube can separate, potentially causing loss of vehicle control and increasing crash risk.

    Product
    SETRA — SETRA S417
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V139000·2016-03-07

    Thor Motor Coach Recalls 2014-2016 Hurricane and Windsport Motor Homes

    Thor Motor Coach is recalling 385 model year 2014-2016 Hurricane and Windsport motor homes because heat from the exhaust system may cause a storage compartment to melt, increasing the risk of fire.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH, THOR MOTOR WINDSPORT, HURRICANE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16E018000·2016-03-07

    ZF Front Control Arm Recall Due to Potential Tube Separation

    ZF Group is recalling specific front control arms where a manufacturing defect may cause the tube to separate from the shaft, potentially leading to loss of vehicle control.

    Product
    SUSPENSION:FRONT:CONTROL ARM recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V133000·2016-03-04

    Prevost Recalls Coaches Due to Fuel Line Fire Risk

    Prevost is recalling specific 2011-2016 coach models because a missing clip allows the coolant line to rub against the fuel hose, potentially causing a fuel leak and engine compartment fire.

    Product
    PREVOST — PREVOST H3-41, H3-45, H3-VIP, X3-VIP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V131000·2016-03-04

    Prevost Recalls X3-45 Buses Due to Cracking Passenger Seat Frames

    Prevost is recalling 2015-2016 X3-45 buses because cracks in sliding passenger seats may compromise structural integrity, increasing injury risk in crashes.

    Product
    PREVOST — PREVOST X3-45
    Category
    Vehicle
    Distribution
    Distributed nationwide