The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

2051–2075 of 15052

  • SevereNHTSA·24V556000·2024-07-25

    Second Navistar recall covers incorrectly heat treated tie rod ball studs

    A second Navistar recall covers certain 2025 International HV, HX, LT, MV and RH vehicles whose tie rod ball studs may have been incorrectly heat-treated. 573 units affected.

    Product
    INTERNATIONAL — INTERNATIONAL HX, LT, RH, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V558000·2024-07-25

    Nova Bus Recalls 2016-2019 LFS Models Due to Brake Chamber Defect

    Nova Bus is recalling 2016-2019 LFS and LFS Artic buses because a defective brake chamber may leak air, causing unexpected braking, overheating, or fire.

    Product
    NOVA BUS — NOVA BUS LFS ARTIC, LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V560000·2024-07-25

    Nissan Ariya inverter software may shut down the EV system

    Nissan is recalling certain 2023 Ariya vehicles because the inverter software may misdiagnose an error and shut down the EV system, resulting in a loss of drive power.

    Product
    NISSAN — NISSAN ARIYA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V554000·2024-07-24

    Tesla hood latches may not detect an unlatched hood after opening

    Tesla is recalling certain 2020-2024 Model 3, Model S, Model X and Model Y vehicles because the hood latch assembly may fail to detect an unlatched hood. 1,849,638 units affected.

    Product
    TESLA — TESLA MODEL S, MODEL 3, MODEL Y, MODEL X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V552000·2024-07-24

    A&J Vans Recalls 2023 Ford Transit Vehicles Due to Seat Defect

    A&J Vans is recalling 2023 Ford Transit vehicles because the seat recliner mechanism may fail to engage, increasing injury risk during a crash.

    Product
    A&J VANS — A&J VANS FORD TRANSIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V545000·2024-07-23

    Capacity Recalls 2023 TJ Series Vehicles Due to Steering Gear Defect

    Capacity of Texas is recalling 2023 TJ 5000, 6500, and 9000 vehicles because steering gear assemblies may have fewer recirculating balls than required, risking loss of steering control.

    Product
    CAPACITY — CAPACITY TJ 5000, TJ 9000, TJ 6500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V550000·2024-07-23

    Indian motorcycle rear suspension pushrods may buckle under load

    Indian Motorcycle is recalling certain 2024 Chieftain, Challenger, Pursuit, Roadmaster and Springfield motorcycles because the rear suspension pushrod may buckle under load.

    Product
    INDIAN — INDIAN ROADMASTER LIMITED, SPRINGFIELD DARK HORSE, ROADMASTER, CHALLENGER LIMITED
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V551000·2024-07-23

    Storyteller Overland Recalls 2024 GXV Next for Incorrect Load Label

    Storyteller Overland is recalling 2024 GXV Next vehicles because incorrect cargo capacity labels may allow overloading, increasing crash risk.

    Product
    STORYTELLER OVERLAND — STORYTELLER OVERLAND GXV NEXT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V546000·2024-07-22

    Motiv recalls electric chassis vehicles due to high-voltage software defect

    Motiv Power Systems is recalling 2019-2024 electric chassis vehicles because a software error may shut down high-voltage batteries, causing loss of power steering and braking.

    Product
    MOTIV — MOTIV F-53 BEV CHASSIS, F-59 BEV CHASSIS, E-450 BEV CHASSIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V547000·2024-07-22

    Motiv E-450 BEV Chassis Recalled for Wiring Damage Risk

    Motiv Power Systems is recalling 2021-2024 E-450 BEV chassis vehicles because damaged CAN signal wires could cause a loss of drive power, increasing crash risk.

    Product
    MOTIV — MOTIV E-450 BEV CHASSIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E061000·2024-07-19

    Ford Recalls Tie Rod Assemblies Due to Potential Steering Failure

    Ford is recalling specific front axle tie rod assemblies because incorrectly heat-treated ball studs may break, potentially causing loss of steering control.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V543000·2024-07-19

    Blue Bird Recalls School Buses Due to Weak Roof Joints

    Blue Bird is recalling 2019-2023 Vision and All American school buses because roof joints may be too weak, risking panel separation in a crash.

    Product
    BLUE BIRD — BLUE BIRD VISION SCHOOL BUS, ALL AMERICAN, ALL AMERICAN SCHOOL BUS, VISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V542000·2024-07-19

    Ford Recalls 2023-2024 Transit Vehicles for Steering Assist Loss Risk

    Ford is recalling 2023-2024 Transit vehicles with the Trail package because corrosion in the steering system may cause a loss of power assist, increasing crash risk.

    Product
    FORD — FORD TRANSIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V544000·2024-07-19

    Doosan Portable Generator Trailer Recalled for Improperly Tightened Lug Nuts

    Doosan is recalling 2024 Bobcat PG25 portable generator trailers because improperly tightened wheel lug nuts may allow wheels to detach, increasing crash risk.

    Product
    DOOSAN PORTABLE POWER — DOOSAN PORTABLE POWER MOBILE GENERATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V539000·2024-07-18

    Hyundai Recalls 2023 Xcient Trucks for Steering Control Risk

    Hyundai is recalling 2023 Xcient vehicles because the pitman arm may not be secured properly, which can result in a loss of steering control and increase the risk of a crash.

    Product
    HYUNDAI — HYUNDAI XCIENT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V538000·2024-07-18

    Chrysler Recalls 2019-2021 Pacifica Plug-In Hybrids for Fire Risk

    Chrysler is recalling 2019-2021 Pacifica Plug-In Hybrids because the battery pack may cause a vehicle fire while parked. Owners should park outside and avoid charging until repairs are completed.

    Product
    CHRYSLER — CHRYSLER PACIFICA PLUG-IN HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V536000·2024-07-18

    Chrysler Recalls 2017-2018 Pacifica Plug-In Hybrids for Fire Risk

    Chrysler is recalling 2017-2018 Pacifica Plug-In Hybrid vehicles because the battery pack may cause a fire while parked. Owners should park outside and avoid charging until repairs are completed.

    Product
    CHRYSLER — CHRYSLER PACIFICA PLUG-IN HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V540000·2024-07-18

    2024 Honda Prologue Front Suspension Control Arm Fracture Recall

    Honda is recalling 2024 Prologue vehicles because the right front lower control arm may contain a manufacturing defect that can fracture, causing loss of vehicle control and increasing crash risk.

    Product
    HONDA — HONDA PROLOGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V541000·2024-07-18

    2021–2025 Winnebago Ekko Motorhomes Solar Charging System Fuse Melt Risk

    Winnebago is recalling 2021–2025 Ekko motorhomes due to inadequate over-current protection in the solar charging system, which can cause the fuse to melt and increase fire risk. Dealers will replace the solar controller fuse and related components at no charge.

    Product
    WINNEBAGO — WINNEBAGO EKKO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V535000·2024-07-17

    2023–2024 Suzuki DL800 Motorcycle Rear Tire Tread Separation

    Suzuki is recalling certain 2023–2024 DL800 motorcycles because the rear tire may crack or deform, causing tread separation and loss of vehicle control. Owners should not ride the motorcycle until the rear tire is replaced.

    Product
    SUZUKI — SUZUKI DL800
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V533000·2024-07-16

    2024 Porsche Cayenne Front Suspension Control Arm May Crack and Fail

    Porsche is recalling 2,475 2024 Cayenne vehicles due to potentially cracked driver's side front upper control arms that may break and cause loss of steering control.

    Product
    PORSCHE — PORSCHE CAYENNE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V532000·2024-07-16

    Triple E RV Recalls Wonder Motorhomes Due to Generator Securing Defect

    Triple E Recreational Vehicles is recalling 2020-2024 Wonder motorhomes because the floor structure may be inadequately secured, allowing the generator to fall.

    Product
    TRIPLE E RV — TRIPLE E RV WONDER
    Category
    Vehicle
    Distribution
    Distributed nationwide