The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1826–1850 of 7515

  • SevereNHTSA·22V100000·2022-02-22

    2021 Porsche Taycan: Center Seat Belt Buckle May Block Child Seat Anchors

    Porsche is recalling 2020-2021 Taycan vehicles with optional rear center seats. The center seat belt buckle wiring harness may obstruct access to child seat anchors, preventing proper installation.

    Product
    PORSCHE — PORSCHE TAYCAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V096000·2022-02-18

    Kia Recalls 2014 Soul Vehicles Due to Air Bag Software Defect

    Kia is recalling 2014 Soul vehicles because the front air bags may not deploy in a crash if the control unit loses communication with sensors.

    Product
    KIA — KIA SOUL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V098000·2022-02-18

    Mercedes-Benz Recalls 2020 GLE 350 for Wiring Harness Defect

    Mercedes-Benz is recalling 2020 GLE 350 vehicles because an unsecured wiring harness may disable power steering, headlights, or wipers, increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLE 350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V093000·2022-02-17

    Kia Recalls 2013-2014 Optima Vehicles for Fuel Hose Fire Risk

    Kia is recalling 2013-2014 Optima vehicles previously repaired under recall 20V-100 because a damaged or missing heat-protective tape on the low-pressure fuel hose can cause a fuel leak and increase fire risk.

    Product
    KIA — KIA OPTIMA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V091000·2022-02-17

    2022 Chevrolet Corvette rear driveshaft defect may cause loss of power

    General Motors is recalling 2021-2022 Chevrolet Corvette vehicles whose rear half-shaft assemblies may be missing ball bearings. This can cause sudden loss of drive power, increasing crash risk.

    Product
    CHEVROLET — CHEVROLET CORVETTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V089000·2022-02-16

    Ford E-350 and E-450 Power Steering Hydraulic Defect Recall

    Ford is recalling certain 2021-2022 E-350 and E-450 vehicles with dual rear wheels due to inadequate power steering line connections. This defect may cause sudden loss of power steering fluid, resulting in loss of steering and brake assist.

    Product
    FORD — FORD E-450, E-350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V077000·2022-02-11

    Chrysler Recalls 2017-2018 Pacifica Plug-In Hybrids for Fire Risk

    Chrysler is recalling 2017-2018 Pacifica Plug-In Hybrid vehicles because a fire can occur while parked. Owners should park outside and avoid recharging until repairs are completed.

    Product
    CHRYSLER — CHRYSLER PACIFICA PLUG-IN HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V056000·2022-02-03

    Hyundai Recalls Vehicles Due to ABS Module Fire Risk

    Hyundai is recalling specific 2014-2019 models because a faulty ABS module could cause an electrical short and engine compartment fire.

    Product
    HYUNDAI — HYUNDAI TUCSON, SANTA FE, SANTA FE SPORT, SANTA FE XL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V061000·2022-02-03

    Honda Recalls 2021 CBR1000RR-R Fireblade SP Motorcycles for Fire Risk

    Honda is recalling 2021 CBR1000RR-R Fireblade SP motorcycles because an overheating exhaust pipe could melt the oil cooler pipe, causing a leak that increases the risk of fire or crash.

    Product
    HONDA — HONDA CBR1000RR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V053000·2022-02-02

    2021-2022 Jayco and Entegra motorhomes recalled for loose tie rod clamps

    Jayco and Entegra are recalling certain 2021-2022 Class C motorhomes with loose tie rod clamps that could lead to steering loss and increased crash risk.

    Product
    JAYCO — JAYCO, ENTEGRA SENECA, ACCOLADE, ACCOLADE XL, SENECA PRESTIGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V051000·2022-02-02

    Kia Recalls Sportage and K900 Models for Fire Risk

    Kia is recalling 2014-2018 Sportage and K900 vehicles because a faulty module could cause an engine compartment fire.

    Product
    KIA — KIA SPORTAGE, K900
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V047000·2022-02-01

    Seagrave Recalls 2021 Capitol and Marauder Vehicles for Axle Defect

    Seagrave is recalling 2021 Capitol and Marauder vehicles because a rear axle drive pinion may fracture, potentially engaging the parking brake unexpectedly and increasing crash risk.

    Product
    SEAGRAVE — SEAGRAVE CAPITAL, MARAUDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V042000·2022-01-28

    Mercedes-Benz Recalls 2021 AMG GT Black Series for Wiring Harness Defect

    Mercedes-Benz is recalling 2021 AMG GT Black Series vehicles because an incorrectly sized front wheel speed sensor wiring harness may damage, impairing safety systems and increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22E005000·2022-01-28

    Samsung SDI Recalls High Voltage Battery Packs for Sudden Power Loss

    Samsung SDI is recalling specific high voltage battery packs that may fail, causing a sudden loss of drive power and increasing crash risk.

    Product
    ELECTRICAL SYSTEM:PROPULSION SYSTEM:TRACTION BATTERY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22E004000·2022-01-27

    Prevost Recalls Seat Brackets That May Fail in Crashes

    Prevost is recalling certain seat brackets that may not meet strength requirements, increasing injury risk in a crash.

    Product
    SEATS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V032000·2022-01-26

    Pierce Fire Trucks Recalled for Fuel Tube Cracking and Leak Risk

    Pierce Manufacturing is recalling 2015-2021 Enforcer, Quantum, Velocity, and Arrow XT fire trucks because fuel tubes may crack and leak high-pressure fuel, increasing fire risk.

    Product
    PIERCE — PIERCE ENFORCER, QUANTUM, VELOCITY, ARROW XT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V028000·2022-01-24

    Inland Empire Trailers Recalls 2021 Models Due to Axle Spindle Nut Issues

    Inland Empire Trailers is recalling 50 units of 2021 trailers because improperly tightened axle spindle nuts may cause overheating and loss of control.

    Product
    INLAND EMPIRE TRAILERS — INLAND EMPIRE TRAILERS CUSTOM TRAILER, UTILITY/ DUMP TRAILER, FLAT DECK TRAILER, ENCLOSED TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V023000·2022-01-21

    BMW Recalls 2019-2020 K 1600 Motorcycles for Rear Suspension Defect

    BMW is recalling 2019-2020 K 1600 GT, GTL, and B motorcycles because a rear suspension link strut may be insufficiently strong, potentially affecting stability and increasing crash risk.

    Product
    BMW — BMW K 1600 GTL, K 1600 GT, K 1600 B
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V025000·2022-01-21

    Rosenbauer Fire Trucks Recalled for Rear Axle Drive Pinion Fracture Risk

    Rosenbauer America is recalling 127 Commander, Warrior, and Avenger vehicles because a rear axle drive pinion may fracture, potentially engaging the parking brake without warning.

    Product
    ROSENBAUER — ROSENBAUER COMMANDER, WARRIOR, AVENGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22E003000·2022-01-20

    Pacific Trailer Recalls RAM A Frame Couplers Due to Welding Defect

    Pacific Trailer is recalling RAM A Frame 2 5/16" couplers because improper welding may cause the trailer to separate from the tow vehicle.

    Product
    EQUIPMENT:RECREATIONAL VEHICLE/TRAILER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide