The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

10201–10225 of 15078

  • SevereNHTSA·16V311000·2016-05-17

    BMW Recalls 2011 X5 and X6 Models for Driveshaft Defect

    BMW is recalling 21,493 2011 X5 and X6 vehicles because a front driveshaft joint may fail, increasing crash risk.

    Product
    BMW — BMW X6 ACTIVEHYBRID SAC, X5 DIESEL SAV, X5, X6
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalNHTSA·16E044000·2016-05-16

    Takata Frontal Passenger Air Bag Inflator Recall for Specific States

    Takata is recalling specific frontal passenger air bag inflators used in vehicles registered in 22 states due to a risk of rupture.

    Product
    AIR BAGS:FRONTAL:PASSENGER SIDE:INFLATOR MODULE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V306000·2016-05-16

    Mercedes-Benz Recalls 2016 SLK300 Vehicles for Rear Tie Rod Defect

    Mercedes-Benz is recalling 327 model year 2016 SLK300 vehicles because improperly manufactured lock nuts on the rear wheel tie rods may cause the rear axle to steer independently, increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SLK300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V304000·2016-05-16

    Jayco Recalls 2016 Jay Flight SLX Trailers Due to Propane Tank Bolt Defect

    Jayco is recalling 2016 Jay Flight SLX travel trailers because missing lock washers may allow the propane tank to detach, increasing crash risk.

    Product
    JAYCO TRAVEL TRAILER — JAYCO TRAVEL TRAILER JAY FLIGHT SLX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16E042000·2016-05-16

    Takata Frontal Passenger Air Bag Inflator Rupture Recall

    Takata is recalling specific frontal passenger air bag inflators that may rupture due to humidity and heat exposure, posing a risk of serious injury or death.

    Product
    AIR BAGS:FRONTAL:PASSENGER SIDE:INFLATOR MODULE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V302000·2016-05-16

    Fiat 500 Recall: Manual Transmission Clutch Spring May Fracture

    Chrysler is recalling 2012-2016 Fiat 500 vehicles with manual transmissions because the clutch diaphragm spring may fracture, potentially preventing gear shifting.

    Product
    FIAT — FIAT 500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16E041000·2016-05-16

    Chrysler Recalls Mopar Canvas Seat Covers for RAM Trucks

    Chrysler is recalling aftermarket Mopar canvas seat covers for 2012-2016 RAM trucks because they can impede airbag deployment, increasing injury risk in a crash.

    Product
    DODGE — DODGE, RAM RAM 1500, 1500, 3500, RAM 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V300000·2016-05-16

    Chrysler Recalls 2016 Minivans for Loose Third Row Seatback Nuts

    Chrysler is recalling 2016 Dodge Grand Caravan and Town and Country minivans because third row seatback nuts may be loose, posing an injury risk.

    Product
    DODGE — DODGE, CHRYSLER GRAND CARAVAN, TOWN AND COUNTRY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16E040000·2016-05-13

    ZF Front Axle Recall for Steering Connection Wear Risk

    ZF North America is recalling certain RL 77 and RL 80 EM axle assemblies due to incorrect internal spacers that can cause premature wear in the steering connection.

    Product
    SUSPENSION:FRONT recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V297000·2016-05-13

    Quality Trailers Recalls 2015 Flatbed and Wedge Car Haulers for Axle Defect

    Quality Trailers is recalling 2015 Flatbed Equipment and Wedge Car Hauler trailers because axle lock nuts may loosen, potentially causing the axle to detach and increasing crash risk.

    Product
    QUALITY — QUALITY WEDGE CAR HAULER, EQUIPMENT FLATBED TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V299000·2016-05-13

    Supreme Recalls 2007-2009 Silver Crown and Ponyxpress RVs for Step Defect

    Supreme Corporation is recalling 2007-2009 Silver Crown and Ponyxpress vehicles because a bolt on the electric entry steps may fracture, causing the steps to become unstable.

    Product
    SUPREME — SUPREME PONYXPRESS, SILVER CROWN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V298000·2016-05-13

    Supreme Classic American Trolley Recall for Seat Belt Anchor Weld Defect

    Supreme is recalling 2010-2016 Classic American Trolley vehicles because missing welds on seat brackets may allow seat belt anchors to separate, increasing injury risk in a crash.

    Product
    SUPREME — SUPREME CLASSIC AMERICAN TROLLEY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V295000·2016-05-12

    Champion Challenger Shuttle Buses Recalled for Seat Separation Risk

    Champion is recalling 2016 Challenger shuttle buses because seats may separate from the base frame due to bolt failure, increasing injury risk in a crash.

    Product
    CHAMPION — CHAMPION CHALLENGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V294000·2016-05-12

    Kovatch Mobile Equipment Recalls Firefighting Vehicles Due to Pump Strainer Defect

    Kovatch Mobile Equipment is recalling certain 2016-2017 emergency vehicles because pump intake strainers may be improperly soldered, potentially causing pump damage and reduced firefighting effectiveness.

    Product
    NAVISTAR — NAVISTAR, KME 4400, 7400, PREDATOR SS, PREDATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V296000·2016-05-12

    Supreme Recalls 2011-2014 Vans Due to Fire Risk in Marker Lights

    Supreme Corporation is recalling 2011-2014 Signature Van, Iner-City, and Kold King vehicles because roof marker lights may short circuit and cause the corner caps to catch fire.

    Product
    SUPREME — SUPREME KOLD KING, SIGNATURE VAN, INER-CITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V293000·2016-05-12

    E-One Recalls 2015-2016 Emergency Vehicles Due to Pump Strainer Defect

    E-One is recalling 140 model year 2015-2016 Cyclone II, Quest II, and Typhoon emergency vehicles because pump intake strainers may be improperly soldered.

    Product
    E-ONE — E-ONE CYCLONE II, QUEST II, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V284000·2016-05-11

    2016 Jeep Cherokee Recall for Right Halfshaft Fracture Risk

    Chrysler is recalling 2016 Jeep Cherokee vehicles because the right halfshaft may fracture without warning, increasing crash risk.

    Product
    JEEP — JEEP CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V285000·2016-05-11

    Forest River Recalls 2016-2017 Berkshire and Cross Country RVs for Sway Bar Defect

    Forest River is recalling specific 2016-2017 Berkshire and 2016 Cross Country recreational vehicles because front sway bar brackets may not fit properly, risking detachment and crashes.

    Product
    FOREST RIVER — FOREST RIVER, COACHMEN BERKSHIRE, CROSS COUNTRY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V291000·2016-05-11

    Keystone Recalls 2016-2017 Passport Trailers Due to Axle Defect

    Keystone RV Company is recalling specific 2016-2017 Passport trailers because they were built with axles that have lower capacity than required, increasing the risk of axle failure and a crash.

    Product
    KEYSTONE — KEYSTONE PASSPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide