The Recall Desk
Agency classClass IIOur severity:ModerateFDA (Devices)·Z-0356-2027·Announced 2026-11-11

Corin Unity Knee ASC Modular Handle Recall for Locking Mechanism Failure

Corin Medical is recalling 22 Unity Knee ASC Modular Handles because the locking mechanism may fail, preventing instruments from being disengaged or securely fitted.

The agency’s classification

FDA (Devices): Class II

Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 2/5 (Moderate).

Minor labeling or packaging issue, or a voluntary precautionary recall. Risk of harm is low but real — follow the manufacturer's instructions.

Our severity reasoning: The recall is classified as Class II due to a potential malfunction of the locking mechanism that prevents instruments from being disengaged or securely fitted. The source does not report any illnesses, injuries, or deaths.

Plain-English summary

Corin Medical, Ltd. is recalling 22 units of the Unity Knee ASC Modular Handle (Part Number: 1232040), which is included in the Corin UNITY ASC INSTRUMENT SYSTEM. The recall is due to a potential malfunction where the locking mechanism may fail. If this occurs, any mating instruments already engaged to the handle will not be able to be disengaged, and the handle will be unable to fit securely to any unengaged mating instruments.

The affected units were distributed worldwide, including US nationwide distribution in the states of CA, GA, IL, MI, NC, RI, TX, and UT, as well as in Belgium, France, Germany, and Hungary. The specific lot code for the recalled items is 097921, and the UDI-DI/GTIN is 05056139239656.

Healthcare providers and facilities should stop using the affected handles and contact Corin Medical for instructions on how to return or replace the devices.

The recalled product

Product
Unity Knee ASC Modular Handle included in the Corin UNITY ASC INSTRUMENT SYSTEM. Part Number: 1232040.
Affected units
22

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (2)

  • Part Number: 1232040. UDI-DI/GTIN
  • 05056139239656. Lot Code: 097921.

Distribution

Distributed nationwide across the United States.

The notice also names 8 states specifically:

Same manufacturer · CORIN MEDICAL, LTD.

See all →