restor3d Recalls Veritas Reverse Total Shoulder Replacement Components
restor3d Inc. is recalling specific Veritas Reverse Total Shoulder Replacement components due to a risk of dislocation or revision surgery caused by excessive mechanical loading.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: The recall is classified as FDA Class II, and the source describes a mechanical defect that can result in dislocation or revision surgery. The source does not report any illnesses, injuries, or deaths.
Plain-English summary
restor3d Inc. is recalling 240 units of Veritas Reverse Total Shoulder Replacement components, specifically the 40mm Polymer Liner paired with stem sizes 1 and 2. The affected model/catalog numbers are 3500-140C3, 3500-140U3, 3500-140C1, and 3500-140U1.
The recall was issued because pairing these specific stem sizes with the largest glenosphere diameter creates an excessive mechanical loading configuration. This condition can cause certain polyethylene components to lack adequate retention strength, potentially resulting in dislocation, reduced range of motion, or the need for revision surgery.
The products were distributed nationwide in Texas, Massachusetts, Oklahoma, Florida, Colorado, and North Carolina. The source text does not provide specific instructions for consumers or patients, but the recall is noted as retroactively reported.
The recalled product
- Product
- Veritas Reverse Total Shoulder Replacement, Model/Catalog Number: 3500-140C3, 3500-140U3, 3500-140C1, 3500-140U1, size 1 -2, 40mm Polymer Liner
- Manufacturer
- restor3d Inc.
- Affected units
- 240
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (4)
- All Lot codes/ UDIs:Product Code: 3500-140C3 UDI/GTIN:00840097513492
- Product Code: 3500-140U3 UDI/GTIN:00840097513461
- Product Code: 3500-140C1 UDI/GTIN:00840097513430
- Product Code: 3500-140U1 UDI/GTIN:00840097513409
Distribution
Related recalls
Same manufacturer · restor3d Inc.
See all →- Moderaterestor3d MTP Implant Recall Due to Sterilization Indicator Failure
FDA (Devices) · 2026-10-28
- Highrestor3d Recalls Kinos Axiom Total Ankle Systems with Incorrect Cutting Guides
FDA (Devices) · 2026-09-23
- Highrestor3d Recalls Veritas Standard Glenoid Baseplates Due to Machining Defect
FDA (Devices) · 2026-08-26
- HighEvans Wedge Disposable Trials Orthopedic Surgical Instruments Recalled for Mixed Parts
FDA (Devices) · 2022-05-11
- ModerateCervical Cage Trial Kit Recalled for Incorrect Size Labeling
FDA (Devices) · 2022-05-11
Same hazard · mechanical failure
See all →- SevereBaxter TS7500 MOBIUS Operating Table Column Recalled for Lift Mechanism Failure
FDA (Devices) · 2026-11-11
- ModerateCorin Unity Knee ASC Modular Handle Recall for Locking Mechanism Failure
FDA (Devices) · 2026-11-11
- SevereBaxter TruSystem 7500 Surgical Table Recall for Lift Mechanism Failure
FDA (Devices) · 2026-11-11
- SevereBaxter TruSystem 7000 U Surgical Tables Recalled for Lift Mechanism Failure
FDA (Devices) · 2026-11-11
- SevereBaxter TruSystem 7000 U Operating Tables Recalled for Lift Mechanism Failure
FDA (Devices) · 2026-11-11
Similar recalls
- Highrestor3d Recalls Veritas Standard Glenoid Baseplates Due to Machining Defect
FDA (Devices) · 2026-08-26
- SevereZimmer Biomet Recalls Reverse Shoulder Humeral Trays Due to Fracture Risk
FDA (Devices) · 2017-02-22
- ModerateBiomet Recalls Verso Shoulder Forked Retractors Due to Material Nonconformance
FDA (Devices) · 2016-03-16
- LowBiomet Shoulder Joint Replacement Components Recalled for Incorrect GTIN Codes
FDA (Devices) · 2015-06-17
- HighBiomet Reverse Shoulder System Recalled for Potential Sterile Seal Breach
FDA (Devices) · 2020-12-23
- HighBiomet Recalls Shoulder Implant Components Due to Endotoxin Levels
FDA (Devices) · 2020-06-03