Gamewell-FCI Recalls Fire Alarm Panels Due to Failure to Alert
Gamewell-FCI is recalling approximately 1,000 fire alarm panels because specific configurations may cause the system to fail to detect and respond to fire, smoke, or carbon monoxide alarms.
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (fire alarm) where the system may fail to alert occupants to a fire, smoke, or carbon monoxide hazard, but no injuries or incidents have been reported.
Plain-English summary
Gamewell-FCI is recalling approximately 1,000 ILI-MB-E3 and ILI-S-E3 fire alarm panels used in commercial buildings. The recall is due to a defect where the panels can become non-responsive and fail to detect or respond to alarms from connected detectors.
This issue is limited to a specific configuration of Signaling Line Circuit (SLC) devices. The problem occurs only if the SLC includes at least two of the following detectors in any combination: Acclimate, 4-Warn, Photo/CO, and iFAAST, and if these detectors are addressed within the same FlashScan polling group. Detectors installed in different combinations are not affected. No incidents or injuries have been reported.
The panels were sold by authorized distributors from May 2015 through August 2015 for about $800. Consumers should immediately contact the distributor to obtain a free repair, which involves a firmware upgrade. For more information, contact Gamewell-FCI at 800-274-4324 from 7 a.m. to 7 p.m. ET Monday through Friday or visit www.gamewell-fci.com and click on "Safety Recall".
The recalled product
- Product
- Gamewell-FCI fire alarm panels (ILI-MB-E3 and ILI-S-E3)
- Affected units
- 1,000
Distribution
Distributed nationwide across the United States.
Related recalls
Same hazard · fire alarm failure
See all →- High
- High
- HighHoneywell Recalls Photoelectric Smoke Sensors for Fire Alarm Failure
CPSC · 2019-06-21
- HighLifetone Bedside Fire Alarm and Clock Recalled for Failure to Alert
CPSC · 2018-11-08
- High
Similar recalls
- HighGamewell-FCI Recalls Fire Alarm Control Boards for Software Upgrade
CPSC · 2007-01-31
- High
- High
- HighHoneywell Recalls Photoelectric Smoke Sensors for Fire Alarm Failure
CPSC · 2019-06-21
- High
- HighFire-Lite Fire Alarm Control Panels Recalled Due to Alert Failure
CPSC · 2010-10-05