The Recall Desk

Hazard

Drowning recalls

113 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
113
Critical
10
Severe
11
Most recent
2026-10-08

Of the 113 drowning recalls we have scored against our rubric, 10 (9%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 11 (10%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all drowning recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 113

  • HighCPSC·23021·2022-10-20

    AQUALUNG Apeks Exotec SCUBA Buoyancy Compensators Recalled for Drowning Hazard

    AQUALUNG is recalling Apeks Exotec SCUBA diving buoyancy compensator devices because the dump valve knob can get stuck when inflated, preventing the device from fully inflating and creating a drowning hazard. Approximately 330 units sold nationwide from August 2021 through June 2022 are affected.

    Product
    Apeks Exotec SCUBA Diving Buoyancy Compensator Devices (BCDs)
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·23013·2022-10-13

    Cressi-Sub USA Recalls Scuba Buoyancy Compensator Devices for Drowning Hazard

    Cressi-Sub USA is recalling about 1,350 scuba buoyancy compensator devices (BCDs) with defective inflator hoses that may fail to inflate properly, posing a drowning hazard to divers.

    Product
    Scuba Buoyancy Compensator Devices (BCDs) with LP inflator hose
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·22768·2022-09-01

    Yuboloo Infant Bath Seats Recalled for Drowning Hazard

    Yuboloo is recalling about 1,050 infant bath seats sold on Amazon.com from May to November 2021 because they fail to meet federal safety standards and can tip over in water, posing a drowning hazard to infants.

    Product
    Infant Bath Seats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·22187·2022-07-21

    Aqualung i330R SCUBA Diving Computers Recalled for Altitude Calculation Failure

    Aqualung i330R SCUBA diving computers can fail to adjust for user altitude and display incorrect dive-time calculations above 3,000 feet, creating risks of decompression sickness and drowning.

    Product
    Aqualung i330R SCUBA Diving Computers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·22069·2022-02-02

    SureClose READYFIT 180° Hinge-Closer Sets Recalled for Drowning Hazard

    D&D Technologies is recalling about 1,500 SureClose READYFIT 180° hinge-closer sets because they can malfunction and fail to fully self-close gates, allowing unintended access to pools and posing injury and drowning hazards to young children.

    Product
    SureClose® READYFIT 180° Hinge-Closer Sets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·22713·2021-12-16

    Karmas Far Infant Bath Seats Recalled for Drowning Hazard

    Karmas Far infant bath seats fail federal safety standards and can tip over during use, posing a drowning hazard to babies. About 900 units sold online between August 2017 and October 2021 are affected. No injuries have been reported.

    Product
    Infant Bath Seats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21775·2021-08-19

    Infant Bath Seats Recalled Due to Drowning Hazard

    Frieyss infant bath seats fail to meet federal safety standards and can tip over while in use, posing a drowning hazard to babies. About 120 units were sold exclusively online at Amazon.com from March through April 2021.

    Product
    Infant Bath Seats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·21735·2021-04-01

    BATTOP Foldable Infant Bath Seats Recalled for Drowning Hazard

    BATTOP is recalling about 5,000 foldable infant bath seats sold on Amazon.com because they can tip over, posing a drowning risk to babies.

    Product
    Foldable Infant Bath Seats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·19137·2019-06-12

    Mares Recalls XR Buoyancy Compensation Vests Due to Drowning Hazard

    Mares is recalling XR buoyancy compensation vests because the deflation button can unscrew, causing loss of buoyancy and a drowning hazard. No injuries have been reported.

    Product
    Mares XR buoyancy compensation vests
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·19070·2019-02-21

    Shearwater Recalls Yellow Diving Transmitters Due to Drowning Hazard

    Shearwater is recalling yellow diving pressure transmitters because they may fail to signal tank pressure, posing a drowning hazard to divers.

    Product
    Shearwater yellow diving pressure transmitters
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·19018·2018-10-23

    Zeagle Sport Buoyancy Control Devices Recalled Due to Drowning Hazard

    Huish Outdoors is recalling Zeagle Sport buoyancy control devices because inflator buttons can break, causing rapid air loss or auto-inflation that poses a drowning risk to scuba divers.

    Product
    Zeagle Sport buoyancy control devices (BCDs)
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·18198·2018-08-21

    Confer Plastics Recalls Pool Step Systems Due to Entrapment Hazard

    Confer Plastics is recalling Curve in-pool step systems because children's limbs can become entrapped in side openings, posing a drowning risk.

    Product
    Curve in-pool step systems
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·18181·2018-06-26

    Huish Outdoors Recalls Scuba Diving Regulators Due to Drowning Hazard

    Huish Outdoors is recalling Oceanic and Hollis scuba diving regulators because they can restrict airflow at low tank pressures, posing a drowning hazard to divers.

    Product
    Oceanic and Hollis scuba diving regulators
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·17717·2016-12-01

    Lexibook Baby Bath Seats Recalled for Drowning Hazard

    CPSC recalls about 7,000 Lexibook baby bath seats and chairs because they can tip over, posing a drowning hazard to babies.

    Product
    Lexibook® Baby Bath Seats and Chairs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·17016·2016-10-18

    TUSA Recalls Diving Computers Due to Drowning and Injury Hazards

    TUSA is recalling about 175 DC Solar Link IQ1204 diving computers because they may malfunction and display incorrect readings, posing a drowning and injury hazard.

    Product
    Diving computers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·17007·2016-10-06

    Summer Infant Recalls Bath Tubs Due to Sling Detachment Risk

    Summer Infant is recalling Lil' Luxuries infant bath tubs because the fabric slings can detach, posing risks of impact injury and drowning.

    Product
    Lil' Luxuries infant bath tubs with fabric slings
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·17005·2016-10-06

    Aqua Lung Recalls Powerline Inflators Due to Injury and Drowning Hazards

    Aqua Lung is recalling about 53,000 Powerline inflators because the inflation button can remain depressed, causing uncontrolled ascent and posing injury and drowning hazards.

    Product
    Aqua Lung Powerline inflators
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·16262·2016-09-14

    Zeagle Buoyancy Control Devices Recalled for Drowning Hazard

    Huish Outdoors is recalling Zeagle Grace and Element BCDs because they may leak air, causing loss of flotation and posing a drowning risk to scuba divers.

    Product
    Zeagle brand buoyancy control devices (BCDs)
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·16732·2016-03-10

    Anchor Industries Recalls Safety Pool Covers Due to Drowning Risk

    Anchor Industries is recalling specific safety pool covers because brass-plated snap hooks can break, posing a drowning risk. No injuries have been reported.

    Product
    Safety pool covers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·15739·2015-07-01

    Otteroo Recalls Inflatable Baby Floats Due to Drowning Risk

    Otteroo is recalling about 3,000 inflatable baby floats because seams can leak air and deflate, posing a drowning risk. No injuries have been reported.

    Product
    Otteroo Inflatable Baby Floats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·15022·2014-11-12

    Aqua Lung Recalls Buoyancy Compensators Due to Drowning Hazard

    Aqua Lung is recalling buoyancy compensators with SureLock II handles that may detach, posing a drowning risk. Consumers should stop using them and return them for free replacement.

    Product
    Aqua Lung buoyancy compensators with SureLock II weight pocket handles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·14088·2014-01-23

    Suunto Recalls Scuba Air Hoses Due To Drowning Hazard

    Suunto is recalling about 1,300 scuba high-pressure air hoses sold in the U.S. because they may leak or rupture, causing a loss of breathing gas and posing a drowning hazard.

    Product
    Scuba high-pressure air hoses
    Category
    Consumer Product
    Distribution
    Distributed nationwide