The Recall Desk

Category

Vehicle recalls

NHTSA recalls of passenger vehicles, motorcycles, tires, and child seats.

About vehicle recalls

Vehicle recalls in our database all come from NHTSA. They cover passenger cars, light trucks, SUVs, motorcycles, tires, child safety seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA Campaign Number (a string like 25V123000) and lists every make / model / year combination affected. We carry the full vehicle range so you can search by your own car.

The most common vehicle-recall categories are airbag and seatbelt failures (the consequence is non-deployment in a crash), fuel system defects with fire risk, steering or brake malfunctions, electrical defects in EVs that can cause battery thermal events, software bugs in driver-assist systems, and child-seat harness failures. Recalls for tires almost always relate to a tread-separation risk in a defined production date range.

Every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, with no expiration. If your vehicle has an open recall, your dealer is required to perform the remedy free of charge as long as the vehicle exists. If you're not sure whether your vehicle is affected, the VIN lookup decodes your specific vehicle and cross-references the NHTSA database directly.

351–375 of 15584

  • HighNHTSA·26V450000·2026-07-14

    Winnebago Recalls 2027 Navion and View RVs for Fire Risk

    Winnebago is recalling 2027 Navion and View recreational vehicles because a rooftop fan circuit board may overheat and cause a fire.

    Product
    WINNEBAGO — WINNEBAGO NAVION, VIEW
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V452000·2026-07-14

    2026 Hyundai Kona rear center seat belt buckle failure risk

    Hyundai is recalling certain 2025 Kona Electric and 2026 Kona vehicles because the rear center seat belt buckle may fail to properly restrain an occupant during a crash. Dealers will replace the buckle assembly for free.

    Product
    HYUNDAI — HYUNDAI KONA, KONA ELECTRIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26E045000·2026-07-10

    Tenneco Recalls NAPA Steering Inner Tie Rod Ends for Ford Vehicles

    Tenneco Automotive is recalling NAPA steering inner tie rod ends for certain Ford C-Max, Escape, and Focus models because the stud may separate, causing a loss of steering.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V446000·2026-07-10

    Grand Design Lineage RVs Recalled for Rooftop Fan Fire Risk

    Grand Design is recalling 2026-2027 Lineage RVs because a rooftop fan component may overheat and cause a fire. Dealers will replace the part free of charge.

    Product
    GRAND DESIGN — GRAND DESIGN LINEAGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V444000·2026-07-09

    2026 Volvo VNL, VNR, VHD, VN, VAH trucks recalled for loose steering

    Volvo Trucks is recalling certain 2026 VNL, VNR, VHD, VN, and VAH vehicles because the steering arm may not be tightly fastened to the steering knuckle, risking loss of steering control and crashes.

    Product
    VOLVO — VOLVO VAH, VHD, VN, VNR (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V438000·2026-07-08

    BMW and Toyota vehicles recalled due to engine starter fire risk

    BMW of North America, LLC is recalling various BMW and Toyota Supra models because the engine starter may overheat and catch fire.

    Product
    BMW — BMW, TOYOTA Z4, 430I XDRIVE, 530I XDRIVE, 330I XDRIVE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V437000·2026-07-08

    2026 Toyota Grand Highlander Hybrid rear axle carrier structural defect

    Toyota is recalling certain 2026 Grand Highlander Hybrid and related models because the rear axle carriers may have insufficient material strength and could break, causing loss of vehicle control and increasing crash risk.

    Product
    TOYOTA — TOYOTA, LEXUS GRAND HIGHLANDER, GRAND HIGHLANDER HYBRID, TX, TX HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V441000·2026-07-08

    BMW Recalls 29,119 Vehicles Due to Starter Relay Fire Risk

    BMW is recalling 29,119 vehicles because a corroded starter relay may overheat and short circuit, increasing the risk of a fire.

    Product
    BMW — BMW 530E XDRIVE IPERFORMANCE, 740LE XDRIVE IPERFORMANCE, 530E IPERFORMANCE, 330E IPERFORMANCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V442000·2026-07-08

    PETERBILT 579 Tractors Recalled for Air Brake Valve Installation

    PACCAR is recalling certain 2026–2027 Peterbilt 579 and 2027 Kenworth T680 tractors with a potentially incorrectly installed trailer air connection quick release valve that can cause trailer instability after braking.

    Product
    PETERBILT — PETERBILT, KENWORTH 579, T680
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V440000·2026-07-08

    Shyft Recalls Utilimaster Velocity Vehicles Due to Strobe Light Fire Risk

    Shyft Group is recalling 2016, 2019, and 2021 Utilimaster Velocity vehicles because water entering an improperly sealed strobe light may cause a short circuit and increase the risk of fire.

    Product
    UTILIMASTER — UTILIMASTER VELOCITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V443000·2026-07-08

    Husqvarna and GasGas Motorcycles Recalled for Brake Caliper Cracks

    KTM North America is recalling certain 2022-2024 Husqvarna FE 501S, FE 350S, and 2024 GasGas ES 350 and ES 500 motorcycles due to a potential rear brake caliper crack that could reduce braking ability and increase crash risk.

    Product
    HUSQVARNA — HUSQVARNA, GASGAS FE 501S, ES 500, ES 350, FE 350S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V434000·2026-07-07

    Braun Recalls 2026 Chevrolet Traverse Vehicles Due to Fuel Leak Risk

    Braun is recalling 2026 Chevrolet Traverse vehicles because a missing braze connection on the fuel fill line may allow fuel to leak, increasing the risk of fire.

    Product
    BRAUN — BRAUN CHEVROLET TRAVERSE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V435000·2026-07-07

    Wabash Recalls Econex Refrigerated Bodies Due to Detaching Steps

    Wabash is recalling 2021-2026 Econex Refrigerated Bodies because side door stirrup steps may detach, increasing the risk of injury or a crash.

    Product
    WABASH — WABASH ECONEX REFRIGERATED BODY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V445000·2026-07-07

    Tesla Recalls 2026 Model Y and 2024 Model 3 for Safety Noncompliance

    Tesla is recalling specific 2026 Model Y and 2024 Model 3 vehicles because they lack required safety features and bumper testing. Owners will be offered a repurchase.

    Product
    TESLA — TESLA MODEL 3, MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V436000·2026-07-07

    Subaru Ascent, Forester, and Crosstrek vehicles with incorrect weight labels

    Subaru is recalling certain 2019–2026 Ascent, 2025–2026 Forester, and 2026 Crosstrek Hybrid vehicles due to incorrect Gross Axle Weight Rating labels, which may lead to vehicle overload and increased crash risk.

    Product
    SUBARU — SUBARU ASCENT, FORESTER HYBRID, FORESTER, CROSSTREK HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26E043000·2026-07-07

    Harbor Freight Recalls Kenway LED Towing and Submersible Light Kits

    Harbor Freight Tools is recalling specific Kenway LED towing and submersible light kits because they may not illuminate properly, increasing crash risk.

    Product
    EXTERIOR LIGHTING:TAIL LIGHTS:BULBS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26E042000·2026-07-06

    Prime-Time Recalls 2025-2026 Ford Med Transit Vans with Wheelchair Retractions

    Prime-Time Specialty Vehicles is recalling 2025-2026 Ford Med Transit vans equipped with Q'Straint Max wheelchair retractors that may fail to lock, posing an injury risk.

    Product
    EQUIPMENT ADAPTIVE/MOBILITY:WHEELCHAIR RESTRAINTS/SECUREMENT:CRITICAL FASTENERS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V426000·2026-07-02

    Jayco Recalls 2026 Seismic Fifth Wheel Toy Haulers Due to Fire Risk

    Jayco is recalling 2026 Seismic fifth wheel toy haulers because the inverter may lack a grounding connection, increasing the risk of fire and electrical shock.

    Product
    JAYCO FIFTH WHEEL — JAYCO FIFTH WHEEL SEISMIC
    Category
    Vehicle
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.