351 recalls were announced in June 2012.

What the numbers show

Critical
12
Severe
116
High
146
Moderate
65
Low
12

Of the 351 recalls this month scored against our rubric, 3% are Critical, 33% are Severe.

1–100 of 351

  • SevereNHTSA·12V306000·2012-06-29

    Isuzu Recalls Amigo and Rodeo Sport for Rear Suspension Corrosion

    Isuzu is recalling 1998-2002 Amigo and Rodeo Sport vehicles in 21 states and D.C. due to rear suspension corrosion that may increase crash risk.

    Product
    ISUZU — ISUZU RODEO SPORT, AMIGO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12E025000·2012-06-29

    Thunderbird Brake Hose Recall for Non-Compliant Federal Safety Standards

    Thunderbird Headquarters is recalling specific brake hoses for 1955-1966 Ford Thunderbirds that fail to meet federal safety standards, posing a risk of brake fluid leaks.

    Product
    SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:HOSES, LINES/PIPING, AND FITTINGS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V305000·2012-06-29

    Toyota Recalls 164,601 Vehicles for Accelerator Pedal Sticking Hazard

    Toyota is recalling 164,601 Lexus and Land Cruiser vehicles because the accelerator pedal can get stuck open by floor mats, posing a crash risk.

    Product
    LEXUS — LEXUS, TOYOTA RX350, RX HYBRID, LAND CRUISER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12T014000·2012-06-29

    TBC Recalls Mirada and Big Foot Tires Due to Sidewall Separation Risk

    TBC Corporation is recalling specific Mirada and Big Foot tires due to a manufacturing anomaly that may cause sidewall cracks or separation, potentially leading to rapid air loss and vehicle crashes.

    Product
    TIRES:SIDEWALL recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V307000·2012-06-29

    Zero Motorcycles Recalls 2011-2012 Models Due to Brake Light Switch Defect

    Zero Motorcycles is recalling certain 2011 and 2012 models because the front brake light switch may not activate until significant lever travel occurs, potentially failing to alert following drivers.

    Product
    ZERO — ZERO XD, XU, ZERO DS, ZERO XU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V326000·2012-06-29

    Ford E-350 Recall: Wheelchair Lift Roll Stop Latch Defect

    Prime-Time Specialty Vehicles is recalling one 2010 Ford E-350 Super Van equipped with a Braun Century-2 wheelchair lift due to a potential roll stop latch defect.

    Product
    FORD — FORD E-350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V311000·2012-06-29

    Pierce Trucks Recalled for High-Pressure Fuel Line Fire Risk

    Pierce is recalling 2010-2012 trucks with Detroit Diesel engines because fuel line supports may loosen, causing leaks and potential fires.

    Product
    PIERCE — PIERCE VELOCITY, DASH CF, CONTENDER BIG BLOCK, ARROW XT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V300000·2012-06-28

    Prevost Recalls 2012 Buses Due to Steering Gearbox Bolt Issue

    Prevost is recalling certain 2012 VIP 45, XLII, and X3-45 vehicles because steering gearbox bolts may be too long to be sufficiently torqued, potentially leading to reduced steering function.

    Product
    PREVOST — PREVOST VIP 45, XLII, X3-45
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·12211·2012-06-28

    Hot Spring Spas and Limelight Hot Tubs Recalled Due to Fire Hazard

    Watkins Manufacturing is recalling about 5,600 Hot Spring Spas and Limelight Hot Tubs because loose electrical connections can cause overheating and fire.

    Product
    Hot Spring Spas and Limelight Hot Tubs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·12206·2012-06-28

    Rigo Recalls Children's Lounge Pants and Boxers for Flammability Violation

    Rigo International is recalling about 210,000 children's lounge pants and boxers sold at Academy because they fail federal flammability standards, posing a burn risk.

    Product
    Boys and Girls Pull-On Lounge Pants and Girls Boxers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·12212·2012-06-28

    Harbor Breeze Bath Fans Recalled for Fire Hazard

    Delta Electronics is recalling Harbor Breeze bath fans sold at Lowe's because the heater blades can fail, causing overheating and fire.

    Product
    Harbor Breeze Bath Fans with Heater and Light
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V297000·2012-06-28

    Thomas Built Buses Recall Roof Hatch Defect in Non-School Models

    Daimler Trucks North America is recalling 163 Thomas Built non-school buses because roof hatches may fail to meet federal emergency exit standards.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER C2, MINOTOUR, SAF-T-LINER EF, SAF-T-LINER HDX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V296000·2012-06-28

    Thomas Built Buses Recall School Buses with Defective Roof Hatches

    Daimler Trucks North America is recalling certain Thomas Built school buses because roof hatches may be too difficult to open in an emergency.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES, THOMAS BUILT SAF-T-LINER HDX, SAF-T-LINER C2, SAF-T-LINER EF, MINOTOUR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V301000·2012-06-28

    Chevrolet Captiva Sport Recalled for Park Brake Cable Defect

    General Motors is recalling 2012 Chevrolet Captiva Sport vehicles because the park brake cable may separate, causing the vehicle to roll.

    Product
    CHEVROLET — CHEVROLET CAPTIVA SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12210·2012-06-28

    IKEA Recalls Track Lighting Systems Due to Electric Shock Hazard

    IKEA is recalling specific 365+ SÄNDA track lighting systems because a defective ground connection poses an electric shock hazard. No injuries have been reported.

    Product
    IKEA 365 + SÄNDA track, 28" and 45"
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V302000·2012-06-28

    BMW Recalls 2011 ActiveE and 2012 Z4 for Steering Loss Risk

    BMW is recalling 2011 ActiveE and 2012 Z4 vehicles because electrical variations may cause sudden loss of power steering, increasing crash risk.

    Product
    BMW — BMW ACTIVEE, Z4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-1476-2012·2012-06-27

    Indonesian Food Mart Recalls Tempeh Super Starter Yeast Due to Salmonella

    Indonesian Food Mart is recalling Tempeh Super Starter Yeast because the imported product tested positive for Salmonella. The product was distributed nationwide and internationally.

    Product
    Tempeh Super Starter Yeast, Rhizopus Oligosporus cultures, soybean rice flour, packaged in clear plastic packages in 30 gm, 50 gm, 250 gm, and 1000 gm sizes and labeled in part ***Indonesianfoodmart.com***
    Category
    Food
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-1463-2012·2012-06-27

    Santos Cinnamon Sticks Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling cinnamon sticks because they were packaged on equipment shared with peanuts and wheat, posing an allergen risk.

    Product
    Santos Brand, Cinnamon Sticks packed in clear plastic bags, 7oz, 14oz
    Category
    Food
    Distribution
    1 state
  • CriticalFDA (Food)·F-1475-2012·2012-06-27

    Indonesian Food Mart Recalls Tempeh Starter Yeast for Salmonella

    Indonesian Food Mart is recalling Tempeh Starter Yeast because it tested positive for Salmonella. The product was distributed nationwide and internationally.

    Product
    Tempeh Starter Yeast, Rhizopus Oligosporus cultures, soybean rice flour, Original, packaged in clear plastic packages in 30gm, 50gm, 250 gm, and 1000 gm sizes and labeled in part ***Indonesianfoodmart.com***
    Category
    Food
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1386-2012·2012-06-27

    Physicians Total Care Recalls Morphine Sulfate Tablets Due to Labeling Error

    Physicians Total Care is recalling Morphine Sulfate tablets because bottles may be mislabeled, potentially containing the wrong formulation.

    Product
    Morphine Sulfate Immediate Release tablet, 30 mg/120 tablet bottles, Rx only, Physician Total Care, Inc, Tulsa, OK 74146-6234, NDC 54868-4973-00
    Category
    Drug
    Distribution
    1 state
  • CriticalFDA (Food)·F-1466-2012·2012-06-27

    Santos Deggi Mirch Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling Deggi Mirch spice products because they were packaged on shared equipment with peanuts and wheat, posing an allergen risk.

    Product
    Santos Brand, Deggi Mirch (Red Capsicum & Kashmiri Red Chile Powder) packed in clear plastic bags, 7 ounces, 14 ounces, 2 pounds
    Category
    Food
    Distribution
    1 state
  • CriticalFDA (Food)·F-1471-2012·2012-06-27

    Santos Mustard Seeds Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling mustard seeds due to cross-contact with peanuts and wheat on shared equipment, which were not declared on the packaging.

    Product
    Santos Brand, Mustard Seeds packed in clear plastic bags, 3.5 ounces, 16 ounces
    Category
    Food
    Distribution
    1 state
  • CriticalFDA (Food)·F-1472-2012·2012-06-27

    Santos Brand Urid Split Lentils Recalled for Undeclared Peanuts and Wheat

    Santos Inc. is recalling Urid Split Lentils because they were processed on shared equipment with peanuts and wheat, which are not listed on the packaging.

    Product
    Santos Brand, Urid Split (Lentils) packed in clear plastic bags, 2 pounds, 4 pounds
    Category
    Food
    Distribution
    1 state
  • CriticalFDA (Food)·F-1443-2012·2012-06-27

    Club Chef Salsa Recalled Due to Salmonella Contamination in Jalapenos

    Club Chef LLC is recalling specific salsa products because fresh jalapeno peppers used in manufacturing were found to be contaminated with Salmonella.

    Product
    Salsa in 12 oz., 16 oz., and 5 lb. plastic containers. The product labels reads as follows: PREMIUM QUALITY Private Selection Natural***SALSA NO PRESERVATIVES KEEP REFRIGERATED NET WT 12 OZ (340g)***INGREDIENTS: Tomatoes***Jalapeno***DISTRIBUTED BY: INTER-AMERICAN PRODUCTS…
    Category
    Food
    Distribution
    6 states
  • CriticalFDA (Food)·F-1541-2012·2012-06-27

    Gills Onions Recalls Diced Red Onions Due to Listeria Risk

    Gills Onions, LLC is recalling 1/4" Diced Red Onions because lab results indicate potential contamination with Listeria monocytogenes.

    Product
    1/4" Diced Red Onions, 5 LB. Bag
    Category
    Food
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-1540-2012·2012-06-27

    Gills Onions Recalls Diced Red Onions Due to Listeria Risk

    Gills Onions, LLC is recalling 3/8" Diced Red Onions, 5 LB. Bag, because lab results indicate potential contamination with Listeria monocytogenes.

    Product
    3/8" Diced Red Onions, 5 LB. Bag
    Category
    Food
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-1473-2012·2012-06-27

    Santos Brand Suji Flour Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling 2-pound bags of Suji (Farina) because routine inspections found the product was processed on shared equipment with peanuts and wheat, which are not listed on the packaging.

    Product
    Santos Brand, Suji (Farina) packed in clear plastic bags, 2 pounds
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1437-2012·2012-06-27

    True World Foods Recalls Frozen Oysters for Insanitary Conditions

    True World Foods San Francisco LLC is recalling frozen half-shell oysters processed by Dai One Food Co., LTD due to insanitary conditions that may have contaminated the product.

    Product
    Oyster Frozen Half Shell; 144 Pc/CS Processed by: Dai One Food Co., LTD #150 Jun-RI, Sanyang-UP Tongyeong-City Kyungsangnam-DO. to: Khee Trading, Vernon, CA 90058.
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1523-2012·2012-06-27

    Kerry Foods Recalls Cheddar Beer Type 725554 Due to Metal Fragments

    Kerry Foods is voluntarily recalling Cheddar Beer Type 725554 because the product is contaminated with metal fragments.

    Product
    KERRY, CHEDDAR BEER TYPE 725554 , CONTAINS MILK, Item #725554.465, Net Wt 50 Lb (22.68Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1462-2012·2012-06-27

    Santos Brand Flour Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling All Purpose flour due to cross-contact with peanuts and wheat on shared equipment, which were not listed on the packaging.

    Product
    Santos Brand, All Purpose flour packed in clear plastic bags, 2 lbs, 5lbs
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Devices)·Z-1844-2012·2012-06-27

    FDA Recalls Covidien ROTICULATOR Staplers Due to Sterility Barrier Risk

    The FDA is recalling specific lots of Covidien ROTICULATOR 55-3.5 Single Use Staplers because the sterility barrier may be compromised, posing a risk of infection during surgery.

    Product
    Covidien ROTICULATOR 55-3.5 Single Use Stapler REF# 017612 The RETICULA TOR TM Single Use Staplers have applications in abdominal, gynecologic and pediatric surgery for resection, transection, and creation of anastomosis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1823-2012·2012-06-27

    Arrow Recalls Central Venous Catheters Due to Potential Hub Voids

    Arrow International is recalling 1,085 units of 7FR 3-Lumen Arrowg+ard Blue Plus Central Venous Catheters due to potential voids in the catheter hub that could cause interlumen crossover.

    Product
    Arrow International, Inc. 7FR 3-Lumen Arrowg+ard Blue Plus(R) Pressure Injectable Central Venous Catheter - Catalog number CDC-42703-XP1A The multiple-lumen pressure injectable catheter permits venous access to central circulation and injection of contrast media. The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1468-2012·2012-06-27

    Santos Brand Ginger Powder Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling Santos Brand Ginger Powder because it was packaged on shared equipment with peanuts and wheat, posing an allergen risk.

    Product
    Santos Brand, Ginger Powder packed in clear plastic bags, 7 ounces, 14 ounces, 2 pounds
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1474-2012·2012-06-27

    Santos Garbanzo Beans Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling Santos Brand garbanzo beans because they were cross-packaged with peanuts and wheat flour, posing an allergen risk.

    Product
    Santos Brand, garbanzo beans packed in clear plastic bags, 2 pounds, 4 pounds
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1518-2012·2012-06-27

    Kerry Foods Recalls Sour Cream and Chives Product Due to Metal Fragments

    Kerry Foods is voluntarily recalling Sour Cream & Chives products contaminated with metal fragments. The recall covers 106 bags distributed across 15 US states, Canada, and Chile.

    Product
    KERRY, SOUR CRM & CHIVES 0989 S37SCC, CONTAINS MILK, , Item #I0989.465 , Net Wt 50 Lb (22.68Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1440-2012·2012-06-27

    Ocean Group Recalls Oysters Due to Insanitary Conditions

    Ocean Group is recalling specific oyster products in California because they were prepared under insanitary conditions that may have rendered them injurious to health.

    Product
    Tiny IQF Oysters, 40pk/cs, 8oz.
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1509-2012·2012-06-27

    Kerry Foods Recalls Mac Sauce Mix Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling Mac 7 CHS Sauce Mix because it is contaminated with metal fragments.

    Product
    KERRY, MAC 7 CHS SAUCE MIX 723357 CH723357, CONTAINS MILK, WHEAT, Item # 723357.859, Net Wt 1600 Lb (725.69 Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1534-2012·2012-06-27

    Kerry Foods Recalls Meloblend 1048 Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling Meloblend 1048, a lactic acid product, because it is contaminated with metal fragments.

    Product
    KERRY, MELOBLEND 1048, 95317, CONTAINS MILK, Item # I7067.465, Net Wt 50 Lb (22.68Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Drugs)·D-1385-2012·2012-06-27

    Physicians Total Care Recalls Morphine Sulfate Extended Release Tablets Due to Labeling Error

    Physicians Total Care is recalling Morphine Sulfate Extended Release tablets because bottles may be mislabeled as Immediate Release or vice versa.

    Product
    Morphine Sulfate Extended Release tablet, 30 mg, 60 tablet bottles, Rx only, Physician Total Care, Inc, Tulsa, Ok 74146-6234, NDC 54868-4033-00
    Category
    Drug
    Distribution
    1 state
  • SevereFDA (Devices)·Z-1774-2012·2012-06-27

    Nidek Medical Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling 7,889 oxygen concentrators because a capacitor failure may cause a fire and loss of supplemental oxygen.

    Product
    NIDEK Medical M5C5/ MARK5 NUVO/STD, 230 V~50/60 Hz - 420 W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1438-2012·2012-06-27

    True World Foods Recalls Frozen Oyster Meat for Insanitary Conditions

    True World Foods San Francisco LLC is recalling frozen oyster meat packed by Dong Won Mul San Co. due to insanitary conditions that may have contaminated the product.

    Product
    Frozen Oyster Meat IQF (Z4) 4 lb box Packed by Dong Won Mul San Co. Tongyeong-City, Gyeongsangnam-Do. Imported by Ayana Group, Inc. Washington, CA
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1488-2012·2012-06-27

    Kerry Foods Recalls Cheddar and Sour Cream Products Due to Metal Fragments

    Kerry Foods is voluntarily recalling specific Cheddar & Sour Cream products because they are contaminated with metal fragments.

    Product
    KERRY, CHEDDAR & SOUR CREAM 725775, CONTAINS MILK, Item # 725775.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1539-2012·2012-06-27

    Gills Diced Red Onions Recalled for Listeria Contamination Risk

    Gills Onions, LLC is recalling diced red onions due to potential Listeria monocytogenes contamination identified by lab results.

    Product
    Diced Red Onions, 7oz clear plastic clamshell labeled Gills Onions with the May 17, 2012 use by date, United States UPC 6 43550 00041 2. Fresh Diced Red Onions, Oignons rouges frais, en des, 198 grams, Canadian UPC 6 43550 00045 0.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1787-2012·2012-06-27

    GE Healthcare Recalls Aestiva 7900 Anesthesia Machines Due to Missing Interlock

    GE Healthcare is recalling eight Aestiva 7900 anesthesia machines because a missing interlock slide may allow two vaporizers to deliver agents simultaneously.

    Product
    GE Healthcare, Aestiva/5 7900 SmartVent, anesthesia machine. Used in Datex-Ohmeda Aestiva/5 Anesthesia Systems.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1846-2012·2012-06-27

    FDA Recalls Covidien ROTICULATOR Staplers Due to Sterility Barrier Risk

    The FDA is recalling specific lots of Covidien ROTICULATOR 30-3.5 Single Use Staplers because the sterility barrier may be compromised, potentially affecting surgical safety.

    Product
    Covidien ROTICULATOR 30-3.5 Single Use Stapler REF# 017615 The RETICULA TOR TM Single Use Staplers have applications in abdominal, gynecologic and pediatric surgery for resection, transection, and creation of anastomosis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1778-2012·2012-06-27

    Nidek Medical NUVO LITE Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling 730 NUVO LITE oxygen concentrators because a capacitor failure could cause a fire or loss of oxygen.

    Product
    NIDEK Medical NUVO LITE MODEL 525 OCSI, 115V -60Hz - 330W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1486-2012·2012-06-27

    Kerry Foods Recalls Three Cheese Mini Shells Due to Metal Fragments

    Kerry Foods is voluntarily recalling Three Cheese Mini Shells because the lactic acid-containing products are contaminated with metal fragments.

    Product
    KERRY, THREE CHEESE MINI SHELLS 10109, CH10109 , CONTAINS MILK, CH718592 Item Number I10109.859, Net Wt 1600 Lb (725.69 Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1481-2012·2012-06-27

    Kerry Foods Recalls Nacho Seasoning Contaminated With Metal Fragments

    Kerry Foods is voluntarily recalling specific lots of Nacho Seasoning 0686 due to contamination with metal fragments.

    Product
    KERRY, NACHO SEAS 0686, Contains Milk, Wheat, Net Wt 22.68 KG (50 lb), Item Number 10686.482
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Devices)·Z-1780-2012·2012-06-27

    Nidek Medical NUVO LITE Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling 14,585 NUVO LITE oxygen concentrators worldwide because a capacitor failure could cause a fire or loss of supplemental oxygen.

    Product
    NIDEK Medical NUVO LITE MODEL 925 OCSI, 230V - 50Hz - 300W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1501-2012·2012-06-27

    Kerry Foods Recalls White Cheddar Seasoning Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling White Cheddar Seasoning because it is contaminated with metal fragments. The product was distributed in 15 US states, Canada, and Chile.

    Product
    KERRY, WHITE CHEDDAR SEAS 10230 SE10230, CONTAINS MILK, WHEAT, Item # I10230.859, Net Wt 1600 Lb (725.69Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1524-2012·2012-06-27

    Kerry Foods Recalls Lactic Acid Products Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling lactic acid-containing products, including BATTER G3668, because they are contaminated with metal fragments.

    Product
    KERRY, BATTER G3668, 1520374, CONTAINS MILK AND WHEAT, Item #G3668.MC1, Net Wt 50 Lb (22.68Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1467-2012·2012-06-27

    Santos Garam Masala Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling Garam Masala spice mix because it was packaged on shared equipment with peanuts and wheat, posing an allergen risk.

    Product
    Santos Brand, Garam Masala (Indian Spice Mix) packed in clear plastic bags, 7 ounces, 16 ounces
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1449-2012·2012-06-27

    Woosung America Recalls Pacific Giant Oysters Due to Insanitary Conditions

    Woosung America Corp. is recalling Pacific Giant Oysters imported from Korea because they were prepared or held under insanitary conditions that may have contaminated the product.

    Product
    PACIFIC GIANT) OYSTERS,IQF,KOREA 8 oz*40 Imported by Pacific Giant, Vernon, CA 90058 Product of Korea
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1442-2012·2012-06-27

    Ocean Group Recalls Oysters Due to Insanitary Conditions

    Ocean Group is recalling oysters from Korea because they were prepared or packed under insanitary conditions, posing a potential health risk.

    Product
    half shell Oysters, 144pc/cs
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1532-2012·2012-06-27

    Kerry Foods Recalls Meloblend 737 Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling Meloblend 737 because the product is contaminated with metal fragments.

    Product
    KERRY, MELOBLEND 737, CODE:QO-05358, CONTAINS MILK, Item # I7126.465, Net Wt 50 Lb (22.68Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1465-2012·2012-06-27

    Santos Fennel Seeds Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling fennel seeds due to cross-packaging with peanuts and wheat flour, which were not declared on the packaging.

    Product
    Santos Brand, Fennel Seeds packed in clear plastic bags, 3.5 ounces, 7 ounces, 14 ounces, 2 pounds
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Devices)·Z-1779-2012·2012-06-27

    Nidek Medical NUVO LITE Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling 3,638 NUVO LITE oxygen concentrators because a capacitor failure may cause a fire and loss of supplemental oxygen.

    Product
    NIDEK Medical NUVO LITE MODEL 520 STD, 115V - 60Hz - 330W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1506-2012·2012-06-27

    Kerry Foods Recalls Au Gratin Seasoning Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling Au Gratin Seasoning because it is contaminated with metal fragments. The product was distributed in 15 US states, Canada, and Chile.

    Product
    KERRY, AU GRATIN SEAS 722912, CONTAINS MILK, WHEAT, Item # 722912.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1464-2012·2012-06-27

    Santos Cumin Seeds Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling cumin seeds because routine inspections found they were packaged with peanuts and wheat, posing a risk to allergic consumers.

    Product
    Santos Brand, Cumin Seeds packed in clear plastic bags, 7 ounces, 14 ounces, 2 pounds
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Devices)·Z-1845-2012·2012-06-27

    FDA Recalls Covidien Roticalator Staplers Due to Sterility Barrier Risk

    The FDA is recalling 13,531 units of the Covidien ROTICULATOR 55-4.8 Single Use Stapler because the sterility barrier may be compromised.

    Product
    Covidien ROTICULATOR 55-4.8 Single Use Stapler REF# 017614 The RETICULA TOR TM Single Use Staplers have applications in abdominal, gynecologic and pediatric surgery for resection, transection, and creation of anastomosis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1537-2012·2012-06-27

    Kerry Foods Recalls Sour Cream and Onion Product Due to Metal Fragments

    Kerry Foods is voluntarily recalling specific lots of Sour Cream and Onion product because they are contaminated with metal fragments.

    Product
    KERRY, SOUR CREAM AND ONION 10286, CONTAINS MILK, Item # I10286.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Devices)·Z-1782-2012·2012-06-27

    Nidek Medical Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling MARK5 NUVO oxygen concentrators because a capacitor failure could cause a fire and stop oxygen supply.

    Product
    NIDEK Medical MARK5 NUVO / M5C5, 115 V ~60Hz - 410 W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1448-2012·2012-06-27

    Woosung America Recalls Ocean Green Oysters Due to Insanitary Conditions

    Woosung America Corp. is recalling Ocean Green Oysters because they were prepared or packed under insanitary conditions that may have contaminated the product.

    Product
    OCEAN GREEN)OYSTER LARGE 5lb*6, IQF Imported by: J & S Group 2535E 12th St. #B Los Angeles, CA 90021
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1493-2012·2012-06-27

    Kerry Foods Recalls Creamy Parmesan Seasoning Due to Metal Fragments

    Kerry Foods is voluntarily recalling Creamy Parmesan Seasoning because the product is contaminated with metal fragments.

    Product
    Kerry, CREAMY PARMESAN SEAS S57CP, CONTAINS MILK, WHEAT, Item # 720104.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1479-2012·2012-06-27

    Kerry Creamy Parmesan Seasoning Recalled for Metal Fragment Contamination

    Kerry Foods is voluntarily recalling Creamy Parmesan Seasoning because the product is contaminated with metal fragments.

    Product
    KERRY, CREAMY PARMESAN SEASONING, CONTAINS MILK, Item Number 62310.01, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Food)·F-1542-2012·2012-06-27

    Red Chamber Recalls Frozen Korean Oyster Meat for Insanitary Conditions

    Red Chamber Company is recalling frozen Korean oyster meat in California and Florida due to insanitary conditions that may have contaminated the product.

    Product
    Frozen Korean Oyster Meat I.Q.F.: , 1) 40x8oz., UPC 19964 30091; 2) 1x25lbs, .; 3) 5x4lbs.UPC 19964 30092
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Devices)·Z-1777-2012·2012-06-27

    Nidek Medical Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling 335 MARK5 NUVO 8 oxygen concentrators because a capacitor failure may cause a fire and loss of supplemental oxygen.

    Product
    NIDEK Medical MARK5 NUVO 8 /OCSI, 230 V~50/60Hz - 420 W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1781-2012·2012-06-27

    Nidek Medical NUVO LITE Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling NUVO LITE oxygen concentrators because a capacitor failure may cause a fire and loss of supplemental oxygen.

    Product
    NIDEK Medical NUVO LITE MODEL 925 OCSI, 3LPM 230V - 60Hz - 280W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1775-2012·2012-06-27

    Nidek Medical Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling M5C5/Mark5 Nuvo/OCSI oxygen concentrators because a capacitor failure may cause a fire and loss of supplemental oxygen.

    Product
    NIDEK Medical M5C5/ MARK5 NUVO/OCSI, 230 V~50/60 Hz -420 W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1469-2012·2012-06-27

    Santos Cardamom Recalled Due to Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling cardamom because it was packaged on shared equipment with peanuts and wheat, which are not listed on the label.

    Product
    Santos Brand, Cardamom packed in clear plastic bags, 3.5 ounces, 7 ounces
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1543-2012·2012-06-27

    Oskri Peach Granola Recalled for Unlabeled Cashews

    Oskri Organics Corp. is recalling 1,056 bags of Peach Granola because cashews were added to the product in error, posing a risk to consumers with cashew allergies.

    Product
    Oskri, Peach Granola, Gluten Free, Nut Free, Dairy Free, Vegan, Halal, Kosher, Ingredients: Buck Wheat , Peaches 20% Sunflower Seeds , Apricots, Date Syrup, Chicory Root extract, Rice protein., NET WT 3.5oz (100) G., UPC 66616111743, Oskri, Lake Mills, Wisconsin 53551.
    Category
    Food
    Distribution
    16 states
  • SevereFDA (Food)·F-1470-2012·2012-06-27

    Santos Brand Whole Mace Recalled for Undeclared Peanut and Wheat Traces

    Santos Inc. is recalling Santos Brand Whole Mace because it was cross-packaged with peanuts and wheat, posing an allergen risk.

    Product
    Santos Brand, Whole Mace packed in clear plastic bags, 3.5 ounces, 7 ounces
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1444-2012·2012-06-27

    Woosung America Recalls Frozen Oysters Due to Insanitary Conditions

    Woosung America Corp. is recalling frozen oysters distributed in Northern California because they were prepared or packed under insanitary conditions.

    Product
    Frozen Oysters: 1) CHORIPDONG) FROZEN OYSTER, IQF 8OZ*40; 2) CJ FOOD, INC.)FROZEN OYSTER 8oz*40; Not for Retail Sale, Must be fully cooked before serving. Distributed by CJ Foods, Inc., Commerce, CA; 3) JAYONE FOODS, INC.) FROZEN OYSTER 8 oz*40, IQF, Distributed by Jayone…
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1487-2012·2012-06-27

    Kerry Foods Recalls Parmesan Asiago Seasoning Due to Metal Fragments

    Kerry Foods is voluntarily recalling Parmesan Asiago Type Seasoning because the product is contaminated with metal fragments.

    Product
    KERRY, PARMESAN ASIAGO TYPE SEASONING, CONTAINS MILK, Item # 718622.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Devices)·Z-1776-2012·2012-06-27

    Nidek Medical Oxygen Concentrator Recalled for Fire Hazard

    Nidek Medical is recalling 82 MARK5 NUVO 8 STD oxygen concentrators because a capacitor failure may cause a fire and loss of supplemental oxygen.

    Product
    NIDEK Medical MARK5 NUVO 8 STD, 115 V~60Hz - 500W. Oxygen Concentrator.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1522-2012·2012-06-27

    Kerry Foods Recalls Lactic Acid Products Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling lactic acid products contaminated with metal fragments. The affected items were distributed in 15 U.S. states, Canada, and Chile.

    Product
    KERRY, KF # 10987R, CONTAINS MILK, Item #B16903.01, Net Wt 50 Lb (22.68Kg)
    Category
    Food
    Distribution
    15 states
  • HighFDA (Food)·F-1632-2012·2012-06-27

    Popchips Sea Salt & Vinegar Recalled for Potential Metal Fragments

    Sonora Mills Foods is recalling Popchips Sea Salt & Vinegar snacks because an ingredient may contain metal fragments.

    Product
    popchips¿ Sea Salt & Vinegar, Potato Popped Chip Snack, 0.4 oz (UPC 0 82666 76550 9), 0.8 oz (UPC 0 82666 75500 5), 3 oz (UPC 0 82666 70050 0), 85 g (UPC 0 82666 71240 4 and 0 82666 71240 4)
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1504-2012·2012-06-27

    Kerry Foods Recalls Metal-Contaminated Lactic Acid Products

    Kerry Foods is voluntarily recalling lactic acid products contaminated with metal fragments. The affected items were distributed in 15 US states, Canada, and Chile.

    Product
    KERRY, MELOBLEND 2237 code: d 1.29 edible, CONTAINS MILK, Item # I7097.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • HighFDA (Food)·F-1480-2012·2012-06-27

    Kerry Cheddar Cheese Recalled Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling Cheddar Cheese products contaminated with metal fragments. The recall affects specific lots distributed in the US and Canada.

    Product
    KERRY, CHEDDAR CHEESE, CONTAINS MILK, 701183, R-SE-0056 , Item Number 701183.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • HighFDA (Devices)·Z-1837-2012·2012-06-27

    Terumo Recalls Sarns Flexible Arterial Cannula Due to Foreign Substance

    Terumo CVS is recalling Sarns Flexible Arterial Cannulas because a foreign substance found on the connector surface can be dislodged during use.

    Product
    SARNS FLEXIBLE ARTERIAL CANNULA: 8.0 MM (24 FR) WITH 3/8" CONNECTOR,SUTURE RING, 9.5" (24 CM) LONG. The Sarns High Flow Aortic Arch Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1849-2012·2012-06-27

    Medtronic 0-arm Imaging System Recalled for Navigational Accuracy Issues

    Medtronic is recalling three 0-arm Imaging Systems because software version 3.1.1 does not meet navigational accuracy standards.

    Product
    Medtronic 0-arm Imaging System with Software Version 3.1.1, Catalog Numbers: BI-700-00027-120R and BI-700-00027-120. The 0-arm¿ Imaging System is a mobile x-ray system designed for 2D fluoroscopic and 3D imaging.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1500-2012·2012-06-27

    Kerry Foods Recalls Lactic Acid Products Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling lactic acid-containing products because they are contaminated with metal fragments. The recall affects specific states in the US and Canada.

    Product
    KERRY, NACHO SEAS NAT, CONTAINS MILK, Item # 721108.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • HighFDA (Food)·F-1483-2012·2012-06-27

    Kerry Foods Recalls Lactic Acid Products Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling lactic acid products contaminated with metal fragments. The affected items were distributed in 15 US states, Canada, and Chile.

    Product
    KERRY, PARM. LING. 5734, SEA 5734, CONTAINS MILK, Item # 15734.607, , Net Wt 1000 Lb (453.556 Kg)
    Category
    Food
    Distribution
    15 states
  • HighFDA (Food)·F-1490-2012·2012-06-27

    Kerry Foods Recalls Thick & Cheesy Product Due to Metal Fragments

    Kerry Foods is voluntarily recalling Thick & Cheesy products because they are contaminated with metal fragments.

    Product
    KERRY, THICK & CHEESY 0601, CH0601, CONTAINS MILK, Item Number 10601.859, Net Wt 1600 Lb (725.69 Kg)
    Category
    Food
    Distribution
    15 states
  • HighFDA (Food)·F-1510-2012·2012-06-27

    Kerry Foods Recalls Bacon Ranch Seasoning Due to Metal Fragments

    Kerry Foods is voluntarily recalling Bacon Ranch Seasoning because it is contaminated with metal fragments. The product was distributed in 15 US states, Canada, and Chile.

    Product
    KERRY, BACON RANCH SEAS 723951 S57RB, CONTAINS MILK, Item # 723951.465, Net Wt 50 Lb (22.68 Kg)
    Category
    Food
    Distribution
    15 states
  • HighFDA (Food)·F-1485-2012·2012-06-27

    Kerry Foods Recalls Cheddar and Sour Cream Products Due to Metal Fragments

    Kerry Foods is voluntarily recalling specific lots of Cheddar & Sour Cream products because they are contaminated with metal fragments.

    Product
    KERRY, CHEDDAR & SOUR CREAM 1037, CONTAINS MILK, Item # 717519.360, Net Wt 25 Lb (11.34Kg)
    Category
    Food
    Distribution
    15 states
  • HighFDA (Devices)·Z-1833-2012·2012-06-27

    Terumo Recalls Sarns High-Flow Aortic Arch Cannula Due to Foreign Substance

    Terumo CVS is recalling Sarns High-Flow Aortic Arch Cannulae because a foreign substance was found on the outer surface of some connectors that can be dislodged.

    Product
    SARNS HIGH-FLOW AORTIC ARCH CANNULA: 6.5 MM (20 FR) 00 WITH 3/8" CONNECTOR, 11" (28 CM) LONG. The Sarns High Flow Aortic Arch Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1520-2012·2012-06-27

    Kerry Foods Recalls Lactic Acid Products Due to Metal Fragment Contamination

    Kerry Foods is voluntarily recalling lactic acid products contaminated with metal fragments. The affected items were distributed across multiple US states and Canada.

    Product
    KERRY, KF PART # 117404 , CONTAINS MILK, Item #I10389.02 , Net Wt 50 Lb (22.68Kg)
    Category
    Food
    Distribution
    15 states

Looking for a different month? Back to 2012.