The Recall Desk

Agency

National Highway Traffic Safety Administration

NHTSA oversees recalls of vehicles, tires, child seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA campaign number.

Visit the official NHTSA site →

About NHTSA recalls

NHTSA regulates the safety of every motor vehicle sold in the US plus tires, child seats, and motor-vehicle equipment. Recalls are coordinated under a numbering scheme called the NHTSA Campaign Number — a string like 25V123000 where the first two digits are the year, V is for vehicle (T is for tires, C for child seats, E for equipment), and the rest identifies the campaign. Every vehicle in our database can be looked up by VIN to check whether any active campaigns affect it.

NHTSA recalls are unusual in two ways. First, the cause is usually a defined defect or non-compliance with a Federal Motor Vehicle Safety Standard rather than a pathogen or contamination event — so 'severity' tracks the consequence of the defect (does the airbag fail to deploy, does the steering lose assist, does the fuel tank leak) rather than reported illnesses. Second, every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, for as long as the vehicle is on the road. There's no expiration on a NHTSA campaign.

We enrich every recall with the full make / model / year-range affected so you can see at a glance whether your vehicle is in scope. If you're not sure, the VIN lookup decodes your specific vehicle and cross-references the database. The remedy is always free — usually a dealer visit for a part replacement, software update, or inspection.

8651–8675 of 15405

  • HighNHTSA·18V222000·2018-04-06

    Forest River Surveyor Recalled for Incorrect Federal Tire Placard Information

    Forest River is recalling 2018 Surveyor recreational trailers because the Federal Placard lists incorrect tire sizes and pressures, which could lead to over-inflation and increased crash risk.

    Product
    FOREST RIVER — FOREST RIVER SURVEYOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18E018000·2018-04-05

    Brembo Motorcycle Front Brake Master Cylinders Recalled for Piston Cracking

    Brembo is recalling specific motorcycle front brake master cylinders because the internal piston may crack and fail, potentially causing a loss of front braking ability.

    Product
    SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:MASTER CYLINDER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V219000·2018-04-05

    Newmar Recalls 2018-2019 New Aire Motorhomes Due to Valve Stem Defect

    Newmar is recalling 2018-2019 New Aire motorhomes because a wheel valve stem stabilizer may dislodge, potentially causing tire damage and increasing crash risk.

    Product
    NEWMAR — NEWMAR NEW AIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V221000·2018-04-05

    Honda Recalls 2018 Pilot, Ridgeline, and Acura MDX for Seat Rivet Defect

    Honda is recalling 2018 Pilot, Ridgeline, and Acura MDX vehicles because improperly manufactured seat rivets may break in a crash, increasing injury risk.

    Product
    HONDA — HONDA, ACURA RIDGELINE, PILOT, MDX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V220000·2018-04-05

    Mitsubishi Recalls 2004-2006 Lancers for Air Bag Inflator Defect

    Mitsubishi is recalling 2004-2006 Lancers because passenger air bag inflators may explode during deployment, potentially causing serious injury or death.

    Product
    MITSUBISHI — MITSUBISHI LANCER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V218000·2018-04-05

    Doepker Recalls 2015-2016 Flatdeck Semi Trailers Due to Frame Cracking

    Doepker is recalling 2015-2016 53-foot Tridem Galvanized Highboy Flatdeck Semi trailers because lower rail main beam flanges may crack, potentially causing loads to shift and spill onto the road.

    Product
    DOEPKER — DOEPKER HG FLATDECK SEMI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V213000·2018-04-04

    Ford Recalls 2017-2018 Vehicles for Missing Transmission Roll Pin

    Ford is recalling 2017-2018 F-150, Expedition, Mustang, and Navigator vehicles because a missing transmission roll pin may cause the vehicle to roll away from Park.

    Product
    LINCOLN — LINCOLN, FORD NAVIGATOR, MUSTANG, EXPEDITION, F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V214000·2018-04-04

    Ford Recalls 2018 F-Series and Expedition for Gear Shift Cable Defect

    Ford is recalling 2018 F-650, F-750, F-150, and Expedition vehicles because a gear shift cable clip may not be seated, causing the transmission to be in a different gear than indicated.

    Product
    FORD — FORD EXPEDITION, F-150, F-750 SD, F-650 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V215000·2018-04-04

    Zero Motorcycles Recalls 2012 Models Due to Battery Fire Risk

    Zero Motorcycles is recalling 2012 S, DS, and DSP models because battery wear may cause electrical shorts and fire. Owners should stop riding and charging these vehicles.

    Product
    ZERO — ZERO ZERO S, ZERO DS, DSP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V211000·2018-04-03

    Toyota Recalls 2017-2018 Models for Brake Booster Vacuum Pump Defect

    Toyota is recalling specific 2017-2018 Camry, Highlander, Sienna, Tacoma, and Lexus RX350 vehicles because a manufacturing defect in the brake booster vacuum pump may cause a sudden loss of brake assist.

    Product
    TOYOTA — TOYOTA, LEXUS SIENNA, TACOMA, RX350, HIGHLANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V209000·2018-03-30

    Van Hool Recalls Motorcoaches Due to Seat Belt Buckle Casing Failure

    Van Hool is recalling 2015-2018 motorcoaches because seat belt buckle casings may fail, exposing the buckles and reducing the likelihood of seat belt use.

    Product
    VAN HOOL — VAN HOOL TDX25, CX45, CX35, TD925
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V208000·2018-03-29

    Mercedes-Benz Recalls 2018 Models for Driver Air Bag Inflator Defect

    Mercedes-Benz is recalling 2018 AMG GT, AMG GT C, GLC43 AMG, GLC300, and GLC350e vehicles because defective steel in the driver-side air bag inflator housing may cause rupture during deployment.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLC 350 E, GLC 300, AMG GLC43, AMG GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V203000·2018-03-29

    Alfa Romeo Stelvio Recall for Liftgate Wiring Water Leak

    FCA US LLC is recalling 2018 Alfa Romeo Stelvio vehicles because water leaks into liftgate wiring, causing corrosion that may allow the liftgate to open while driving.

    Product
    ALFA ROMEO — ALFA ROMEO STELVIO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V206000·2018-03-29

    Spartan Gladiator Recall for Front Axle Spindle Failure Risk

    Spartan Motors is recalling 2004-2007 Gladiator emergency response vehicles because front axle spindles may crack and fail, potentially causing a wheel to separate.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V199000·2018-03-29

    Navistar Recalls 2018-2019 International LT Trucks for Fuel Leak Risk

    Navistar is recalling 2018-2019 International LT trucks because a fender splash panel may rub against the fuel line, causing a leak that could lead to fire or crash.

    Product
    INTERNATIONAL — INTERNATIONAL LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18E017000·2018-03-29

    Timoney Front Suspension Recall Due to Axle Spindle Fatigue Cracks

    Timoney Technology is recalling Mark 1 and Gen 2 Independent Front Suspensions because inconsistent machining may cause axle spindle failure and wheel separation.

    Product
    SUSPENSION:FRONT recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V204000·2018-03-29

    Tesla Recalls Model S Vehicles Due to Steering Bolt Corrosion Risk

    Tesla is recalling 2012-2016 Model S vehicles because aluminum steering bolts may corrode and fracture, potentially causing a loss of power steering assist.

    Product
    TESLA — TESLA MODEL S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V207000·2018-03-29

    Mercedes-Benz Recalls 2017-2018 Models Due to Front Seatback Locking Defect

    Mercedes-Benz is recalling specific 2017-2018 C-Class and E-Class vehicles because front seatbacks may not lock properly, increasing injury risk in a crash.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ E 400, C 300, AMG C63S, AMG C43
    Category
    Vehicle
    Distribution
    Distributed nationwide