  • SevereNHTSA·22V700000·2022-09-19

    Liquid Transport Recalls 2022 Hays-LTI PTNTT Trailers for Hub Defect

    Liquid Transport is recalling 2022 Hays-LTI PTNTT trailers because a bearing washer may crack, causing the hub to separate from the axle and increasing crash risk.

    Product
    HAYS — HAYS LTI PTNTT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V703000·2022-09-19

    2016-2023 Kia Sorento and Sportage tow hitch electrical fire hazard recall

    Kia is recalling certain 2016-2023 Sorento and 2017-2022 Sportage models with factory or dealer-installed tow hitch harnesses. Moisture and debris on the harness module can cause an electrical short and fire while parked or driving.

    Product
    KIA — KIA SORENTO, SPORTAGE, SORENTO HYBRID, SORENTO PHEV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V702000·2022-09-19

    Tesla Model 3 window automatic reversal system may pinch occupants

    Tesla recalls 2017–2022 Model 3, 2020–2022 Model Y, and 2021–2022 Model S/X vehicles whose automatic window reversal system may fail to detect obstructions and pinch occupants. A free software update will fix the issue.

    Product
    TESLA — TESLA MODEL 3, MODEL Y, MODEL S, MODEL X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V699000·2022-09-19

    Collins School Bus Recall for Incorrect Emergency Exit Labels

    Collins Bus is recalling 2012-2020 school buses because emergency exit labels may be misplaced or too small, potentially delaying escape during an emergency.

    Product
    COLLINS — COLLINS DE, TL, TH, SL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V698000·2022-09-19

    Prevost Recalls X3-45 Commuter Motorcoaches Due to Incorrect Seat Belt Type

    Prevost is recalling 2021-2023 X3-45 Commuter motorcoaches because the driver's seat has a Type 1 seat belt instead of the required Type 2, which may not adequately protect the driver in a crash.

    Product
    PREVOST — PREVOST X3-45 COMMUTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·032-2022·2022-09-17

    Healthy Choice Korean-Style Beef Recalled For Undeclared Milk Allergen

    USDA recalls 22,061 pounds of Healthy Choice Korean-Style Beef due to undeclared milk and misbranding. No illnesses reported.

    Product
    VICS Acquisition, LLC — Valley International Cold Storage Acquisition, LLC, Recalls Frozen Beef Products Due To Misbranding And Undeclared Allergens
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V697000·2022-09-16

    Autocar Recalls 2022 Xpeditor Trucks Due to Tie Rod Clamp Defect

    Autocar is recalling 236 2022 Xpeditor trucks because improperly heat-treated tie rod clamps may fail, causing tie rods to separate and increasing crash risk.

    Product
    AUTOCAR — AUTOCAR XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V696000·2022-09-16

    Winnebago Travato motorhomes recalled for unintended awning extension

    Winnebago is recalling certain 2019-2023 Travato motorhomes because the retractable awning may extend unintentionally during transit. An extended awning could become a distraction or road hazard, increasing crash risk.

    Product
    WINNEBAGO — WINNEBAGO TRAVATO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V694000·2022-09-16

    Coachmen motorhomes recalled for improperly tightened LPG quick disconnect

    Forest River is recalling certain 2022-2023 Coachmen Leprechaun, Freelander, and Prism motorhomes due to an improperly tightened auxiliary LPG quick disconnect that could cause a gas leak and increase fire risk.

    Product
    COACHMEN — COACHMEN LEPRECHAUN, FREELANDER, PRISM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V695000·2022-09-16

    Motorhome Retractable Awning Unintended Extension During Transit Recall

    Winnebago and Itasca motorhomes have a defective retractable awning that may extend unintentionally while driving. This can distract drivers or create a road hazard, potentially increasing crash risk.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA ERA, VIEW, NAVION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V692000·2022-09-15

    Micro Bird Recalls 2018-2019 G5 Electric School Buses for Fire Risk

    Micro Bird is recalling 2018-2019 G5 electric school buses because improperly crimped wires in the charging port may overheat and cause a fire.

    Product
    MICRO BIRD — MICRO BIRD G5 TRANSIT BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V693000·2022-09-15

    2021 Nissan Versa and Kicks power steering sensor defect

    Nissan is recalling 2021 Versa and Kicks vehicles because an intermittent electrical connection in the power steering torque sensor can disable power steering assist, increasing steering effort and crash risk.

    Product
    NISSAN — NISSAN KICKS, VERSA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22222·2022-09-15

    Cervélo R5 and Caledonia-5 Bicycles Recalled for Fall Hazard

    Cervélo USA recalls about 1,800 Model Year 2022 R5 and Caledonia-5 bicycles and 182 ST31 LT replacement stems because handlebars can slip in the stem, causing loss of control and falls. One injury from a fall has been reported.

    Product
    Model Year 2022 Cervélo R5 and Caledonia-5 bicycles and Cervélo ST31 LT replacement stems
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·22V691000·2022-09-15

    International commercial vehicles recalled for engine connecting rod failure

    Navistar is recalling certain 2018-2021 International HV, HX, LT, and RH vehicles because connecting rod wrist pins may crack, causing engine failure. This could lead to engine shutdown and increase the risk of a crash.

    Product
    INTERNATIONAL — INTERNATIONAL LT, RH, HX, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22772·2022-09-15

    Baby Trend Cityscape Travel Jogger Strollers Parking Brake Failure Recall

    Baby Trend is recalling about 310 Cityscape Travel Jogger Strollers (Model TJ75B12A) because the parking brake can fail, creating a fall and injury risk for children. No injuries have been reported.

    Product
    Cityscape Travel Jogger Strollers, Model TJ75B12A
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1476-2022·2022-09-14

    Milk of Magnesia Recalled Nationwide for Microbial Contamination

    Plastikon Healthcare LLC has recalled Milk of Magnesia USP nationwide due to microbial contamination in non-sterile products. The affected lot (20071A) included approximately 24,400 institutional-use cups.

    Product
    MILK OF MAGNESIA USP, 2400 mg/30 mL, Magnesium Hydroxide, 30 mL cup, packaged in 10 cups per tray, 10 trays per carton, For Institutional Use Only, Major Pharmaceuticals, 17177 N Laurel Park Dr., Suite 233, Livonia, MI 48152, NDC 0904-6846-73.
    Category
    Drug
    Distribution
    Distributed nationwide
  • CriticalCPSC·22221·2022-09-14

    ThyssenKrupp Residential Elevators Recalled Due to Child Entrapment Hazard

    ThyssenKrupp Access Corp. is recalling about 16,800 residential elevators sold between 1996 and 2012 due to an entrapment hazard. Children can become trapped in the gap between exterior and interior doors, resulting in serious injury or death; one child death has been reported.

    Product
    thyssenkrupp Access Corp. Residential Elevators
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1655-2022·2022-09-14

    Philips BiPAP A40 Respiratory Devices Recalled for Motor Assembly Off-Gassing

    Philips is recalling BiPAP A40 respiratory support devices because motor assemblies were manufactured with nonconforming plastic that off-gases volatile organic compounds (VOCs). Approximately 1,414 units have been distributed domestically and internationally.

    Product
    Philips BiPAP A40, Rx Only. To provide noninvasive ventilation support for patients with obstructive sleep apnea syndrome (OSA) and respiratory insufficiency.
    Category
    Medical Device
    Distribution
    42 states
  • SevereNHTSA·22V688000·2022-09-14

    Thomas Built Saf-T-Liner HDX School Buses Recalled for Panel Joint Strength

    Daimler Trucks North America is recalling 2020-2023 Thomas Built Saf-T-Liner HDX school buses because rear side-body panels may have insufficient joint strength.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER HDX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1654-2022·2022-09-14

    Philips BiPAP A30 respiratory device motor assemblies recalled for VOC off-gassing

    Philips Respironics recalls Philips BiPAP A30 respiratory devices due to motor assemblies with nonconforming plastic that off-gases volatile organic compounds (VOCs). Patients should contact the manufacturer immediately.

    Product
    Philips BiPAP A30, Rx Only. To provide noninvasive ventilation support for patients with obstructive sleep apnea syndrome (OSA) and respiratory insufficiency.
    Category
    Medical Device
    Distribution
    42 states
  • SevereFDA (Drugs)·D-1478-2022·2022-09-14

    Antacid Medication Recalled Nationwide for Microbial Contamination Risk

    Plastikon Healthcare LLC is recalling 220,500 cups of antacid containing magnesium hydroxide and aluminum hydroxide due to microbial contamination.

    Product
    Magnesium Hydroxide 1200 mg, Aluminum Hydroxide 1200 mg, Simethicone 120 mg per 30 mL, 30 mL cup, packaged in 10 cups per tray, 10 trays per carton, For Institutional Use Only, Major Pharmaceuticals, 17177 N Laurel Park Dr., Suite 233, Livonia, MI 48152, NDC 0904-6838-73
    Category
    Drug
    Distribution
    Distributed nationwide