The Recall Desk

State

Washington product recalls

73,372 recalls have nationwide distribution and so reach Washington. 8,462 additional recalls listed Washington specifically in their distribution scope.

What the numbers show

Total
8,462
Critical
868
Severe
2,396
Most recent
2026-10-07

Of the 8,462 recalls naming Washington we have scored against our rubric, 868 (10%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,396 (28%) are Severe.

These figures cover only the 8,462 recalls whose distribution notice names Washington specifically. The 73,372 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

18201–18225 of 81834

  • ModerateCPSC·23168·2023-03-30

    Open Cycle Bicycles Recalled Due to Rear Brake Failure Hazard

    Open Cycle UP Ekar, UPPER Ekar, WIDE Ekar, and MIND Ekar bicycles with Campagnolo hydraulic rear disc brakes are being recalled because the rear brake can fail, posing a crash hazard. About 270 units sold nationwide from November 2021 through February 2023 are affected.

    Product
    Open Cycle UP Ekar, UPPER Ekar, WIDE Ekar and MIND Ekar bicycles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • ModerateCPSC·23171·2023-03-30

    Carhartt Men's Work Pants Recalled for Fall Hazard from Hem Loop

    Carhartt Men's Force Relaxed 5 Pocket Work Pants can develop an extended elastic loop at the ankle that poses a trip and fall hazard. About 32,505 units sold at Dick's Sporting Goods from July through November 2022 are affected.

    Product
    Carhartt Men's Force Relaxed 5 Pocket Work Pants
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-0632-2023·2023-03-29

    IWATSUKASEIKA Soybean Flavor Snack Recalled for Undeclared Wheat Allergen

    DAISO CALIFORNIA WAREHOUSE is recalling IWATSUKASEIKA Soybean Flavor snacks because wheat was not declared on the label. Consumers with wheat allergies should not consume this product.

    Product
    IWATSUKASEIKA Soybean flavor 72g -21pieces UPC: 4901037131919 Made in Japan
    Category
    Food
    Distribution
    6 states
  • CriticalFDA (Food)·F-0635-2023·2023-03-29

    YAMANAKAFOODS Salted Hijiki Seaweed 20g Recalled for Undeclared Wheat Allergen

    YAMANAKAFOODS Seasoning - Salted Hijiki Seaweed (20g) is being recalled because the label does not disclose wheat as an ingredient. Consumers with wheat allergies are at risk of allergic reaction.

    Product
    YAMANAKAFOODS Seasoning - Salted Hijiki Seaweed 20g UPC: 4902378014053 Made in Japan
    Category
    Food
    Distribution
    6 states
  • SevereFDA (Food)·F-0628-2023·2023-03-29

    MEITO Lemon Tea Recalled Due to Undeclared Milk Allergen

    MEITO Lemon Tea 4-pack is being recalled because milk allergen was not declared on the label. Consumers with milk allergies should not consume this product.

    Product
    MEITO Lemon Tea 4 Pack UPC: 4902757413507 Made in Japan
    Category
    Food
    Distribution
    6 states
  • SevereNHTSA·23V213000·2023-03-29

    Volkswagen Recalls 2023 ID 4 Vehicles for Door Handle Water Ingress

    Volkswagen is recalling 2023 ID 4 vehicles because water can enter the door handle circuit board, causing doors to open unexpectedly at low speeds.

    Product
    VOLKSWAGEN — VOLKSWAGEN ID 4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V215000·2023-03-29

    2018-2021 Volkswagen Atlas Front Passenger Air Bag Sensor Fault

    Volkswagen is recalling certain 2018–2021 Atlas and 2020 Atlas Cross Sport vehicles because a wiring fault in the passenger occupant detection system may deactivate the front passenger air bag when the seat is occupied.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS, ATLAS CROSS SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0638-2023·2023-03-29

    ITOSEIKA Chocolate Chip Cookies Recalled for Undeclared Milk Allergen

    ITOSEIKA chocolate chip cookies are being recalled due to undeclared milk allergen on the label. Consumers with milk allergies should not consume this product.

    Product
    ITOSEIKA Chocolate chip cookies 10pieces UPC: 4901050111400 Made in Japan
    Category
    Food
    Distribution
    6 states
  • SevereFDA (Food)·F-0631-2023·2023-03-29

    Rice Crackers Recalled Due to Undeclared Wheat Allergen

    DAISO CALIFORNIA WAREHOUSE is recalling IWATSUKASEIKA Ajishirabe Rice Crackers because the label fails to declare wheat. Wheat is a major allergen that can cause severe allergic reactions in sensitive individuals.

    Product
    IWATSUKASEIKA Ajishirabe Rice Crackers UPC: 4901037117746 Made in Japan
    Category
    Food
    Distribution
    6 states
  • SevereFDA (Food)·F-0643-2023·2023-03-29

    Pistachio wasabi snack recalled for undeclared soy allergen

    SENNARIDO Green Snack Pistachio-Wasabi Flavor (90g) is recalled because soy is not declared on the label. Approximately 10,986 units were distributed across California, Washington, Nevada, Texas, New York, New Jersey, and Canada.

    Product
    SENNARIDO Green Snack Pistachio -Wasabi Flavor 90g UPC: 4974120431715 Made in Japan
    Category
    Food
    Distribution
    6 states
  • SevereNHTSA·23V212000·2023-03-29

    Audi Recalls 2020 Q7 Vehicles Due to Front Camera Fire Risk

    Audi is recalling 2020 Q7 vehicles because a software incompatibility may cause the front camera heating element to overheat, increasing the risk of a fire.

    Product
    AUDI — AUDI Q7
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0633-2023·2023-03-29

    Powdered lemon tea recalled for undeclared milk allergen

    MEITO An extra Stick Powdered Lemon Tea is recalled because the product contains milk that is not declared on the label. Consumers with milk allergies who have purchased this product should not consume it.

    Product
    MEITO An extra Stick Powdered Lemon Tea 5packs UPC: 4902757442804 Made in Japan
    Category
    Food
    Distribution
    6 states
  • SevereFDA (Food)·F-0630-2023·2023-03-29

    Sesame sauce recalled due to undeclared wheat allergen

    Shinsei Additive Free Sesame Sauce is being recalled because wheat allergen was not declared on the product label. Consumers with wheat allergies who consume this product may experience allergic reaction.

    Product
    Shinsei Additive Free Sesame Sauce 22g UPC: 4901665004616 Made in Japan
    Category
    Food
    Distribution
    6 states
  • SevereNHTSA·23V218000·2023-03-29

    Kia Recalls 2015-2019 Soul EV Vehicles for Battery Fire Risk

    Kia is recalling 2015-2019 Soul EV vehicles with E400 batteries because an electrical short-circuit could cause a fire. Owners should contact Kia for a free software update or battery replacement.

    Product
    KIA — KIA SOUL EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0640-2023·2023-03-29

    SENNARIDO pistachio snack recalled for undeclared soy allergen

    DAISO CALIFORNIA WAREHOUSE is recalling SENNARIDO Green Snack Pistachio 90g because the product contains undeclared soy, a major food allergen that poses allergic reaction risk to sensitive consumers.

    Product
    SENNARIDO Green Snack Pistachio 90g UPC: 4974120413421 Made in Japan
    Category
    Food
    Distribution
    6 states
  • SevereFDA (Drugs)·D-0488-2023·2023-03-29

    Delsam Pharma Artificial Eye Ointment Recalled for Bacterial Contamination

    Delsam Pharma's Artificial Eye Ointment is being recalled for bacterial contamination in unopened tubes. FDA analysis found non-sterility defects in approximately 50,000 units.

    Product
    Delsam Pharma's Artificial Eye Ointment (Mineral Oil 15%, White Petrolatum 83%), 3.5 grams (1/8 oz.) tube, Distributed By: Delsam Pharma Lic, Bronx, Newyork 10469, NDC 72570 122 35, UPC 3 72570 12235 3.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0642-2023·2023-03-29

    Kurata Menzo Ramen Recalled for Undeclared Coconut Allergen

    DAISO CALIFORNIA WAREHOUSE is recalling Kurata Menzo Meatfree Tonkotsu Ramen Dry due to undeclared coconut on the label. Consumers with coconut allergies who consume this product may experience allergic reactions.

    Product
    Kurata Menzo Meatfree Tonkotsu Ramen Dry 2P 238.8g UPC: 4906436004932 Made in Japan
    Category
    Food
    Distribution
    6 states
  • HighFDA (Food)·F-0636-2023·2023-03-29

    Soft rice crackers recalled for undeclared coconut allergen

    DAISO CALIFORNIA WAREHOUSE is recalling 150YEN HIZATSUKI Soft rice crackers because the product contains coconut that was not declared on the label. Consumers with coconut allergies should not consume this product.

    Product
    150YEN HIZATSUKI Soft rice crackers sea lettuce soy sauce flavor UPC: 4902445210500 Made in Japan
    Category
    Food
    Distribution
    6 states
  • HighFDA (Food)·F-0634-2023·2023-03-29

    Coffee Candy Recalled for Undeclared Coconut Allergen

    Kanro Non sugar coffee candy is recalled because coconut was not declared on the label, posing a risk to consumers with coconut allergies.

    Product
    Kanro Non sugar coffee candy 40g UPC: 4901351013137 Made in Japan
    Category
    Food
    Distribution
    6 states
  • HighFDA (Food)·F-0648-2023·2023-03-29

    Kirkland Signature Colombian cold brew coffee recalled for metal contamination

    Berner Foods Inc. is recalling Kirkland Signature Colombian Cold Brew Coffee due to metal contamination in 231,071 cases distributed across 13 states. Consumers should stop using affected products.

    Product
    Kirkland Signature Colombian Cold Brew Coffee ready-to-drink, 12 fl oz in aluminum can, 12 cans per case
    Category
    Food
    Distribution
    13 states
  • HighFDA (Devices)·Z-1281-2023·2023-03-29

    Raystation Treatment Planning System Collimator Angle Export Defect

    Raystation radiation therapy planning software may not correctly export collimator angle settings when using the DICOM export function. In exported files, the collimator angle may be replaced with zero regardless of the user's selection.

    Product
    Raystation treatment planning system for radiation therapy, Model Numbers 9.0.0, 9.0.1, 9.1.0, 9.2.0, 10.0.0, 10.0.1, 10.0.2, 10.1.0, 10.1.1, 11.0.0, 11.0.1, 11.0.3, 11.0.4, 12.0.0, 12.1.0, 12.1.1, 12.0.3, 12.1.2, 12.0.4, 12.1.3, 13.0.0, 13.1.0. Software Version Numbers 9A, 9B…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0650-2023·2023-03-29

    DG Health Sugar Free Daily Fiber Recalled for Missing Phenylalanine Warning

    DG Health Sugar Free Daily Fiber is recalled for missing a required phenylalanine warning label. People with phenylketonuria (PKU) require this warning to safely use the product.

    Product
    DG Health brand Sugar Free Daily Fiber in 10 oz. plastic containers (UPC: 860005934294).
    Category
    Food
    Distribution
    47 states
  • HighNHTSA·23V211000·2023-03-29

    BMW seats may not restrain occupants properly in crash

    BMW is recalling certain 2019–2021 3-series and X3/X4 models because the seat frame may not have been welded properly to the seat rails, risking occupant injury in a crash.

    Product
    BMW — BMW X4, 330I, M340I, X3
    Category
    Vehicle
    Distribution
    Distributed nationwide