The Recall Desk

State

Oregon product recalls

73,596 recalls have nationwide distribution and so reach Oregon. 7,533 additional recalls listed Oregon specifically in their distribution scope.

What the numbers show

Total
7,533
Critical
873
Severe
2,131
Most recent
2026-10-14

Of the 7,533 recalls naming Oregon we have scored against our rubric, 873 (12%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,131 (28%) are Severe.

These figures cover only the 7,533 recalls whose distribution notice names Oregon specifically. The 73,596 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

1376–1400 of 81129

  • SevereNHTSA·26V480000·2026-07-24

    Yamaha Boat Trailer Recall Issued Due to Tongue Failure Risk

    Midwest Industries is recalling 2027 Yamaha boat trailers because the tongue may fail during towing, causing the trailer to detach and increasing crash risk.

    Product
    YAMAHA — YAMAHA BOAT TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·011-2026·2026-07-24

    Bacon product imported without reinspection recalled

    Maple Leaf Foods Inc. recalls approximately 12,036 pounds of not-ready-to-eat smoked bacon from Canada that was imported without required reinspection. No illnesses or injuries have been reported.

    Product
    Maple Leaf Foods Inc. Recalls Not Ready-To-Eat (NRTE) Bacon Product Imported without the Benefit of Import Reinspection
    Category
    Food
    Distribution
    3 states
  • HighNHTSA·26V482000·2026-07-24

    Frontrunner Recalls 2025 Transit Buses Due to Wheelchair Retract Defect

    Frontrunner is recalling 2025 transit buses because wheelchair retractors may fail to lock, increasing injury risk. Owners will be notified to have parts replaced.

    Product
    FRONTRUNNER — FRONTRUNNER FRONTRUNNER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26634·2026-07-23

    12-Drawer Fabric Dressers Recalled for Tip-Over and Entrapment Hazards

    Romorgniz 12-Drawer Fabric Dressers sold on Amazon pose tip-over and entrapment risks to children if not anchored to the wall. About 10,040 units are affected.

    Product
    Romorgniz 12-Drawer Fabric Dressers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·26636·2026-07-23

    Sviyatp Pool Drain Covers Recalled for Entrapment and Drowning Risk

    About 670 Sviyatp pool drain covers sold online violate federal safety standards and pose entrapment and drowning hazards. Consumers should stop using affected pools immediately and contact Sviyatp for a refund.

    Product
    Sviyatp Pool Drain Covers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V478000·2026-07-23

    BMW S 1000 RR Motorcycles Recalled Due to Potential Engine Stall Risk

    BMW is recalling certain 2020-2026 S 1000 RR motorcycles because vibration may cause ignition lock failure, leading to engine stalls or electrical system failures.

    Product
    BMW — BMW S 1000 RR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26E048000·2026-07-23

    K&N and Spectre Fuel Filters Recalled for O-Ring Disintegration

    K&N Engineering is recalling specific K&N and Spectre replacement fuel filters because the O-ring may disintegrate, causing leaks or clogs.

    Product
    FUEL SYSTEM, OTHER:FUEL FILTER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26638·2026-07-23

    CuddleCubs Creations Teething Toy Sets Recalled for Choking Risk

    CuddleCubs Creations Baby Highchair Teething Toy Sets are recalled due to pull-string teething toys that violate mandatory toy safety standards. The silicone strings can lodge in a child's throat, creating a risk of choking and respiratory distress.

    Product
    CuddleCubs Creations Baby Highchair Teething Toy Sets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·26633·2026-07-23

    EnHomee 9-Drawer Fabric Dressers Recalled for Tip-Over and Entrapment Hazard

    EnHomee 9-Drawer Fabric Dressers sold on Walmart.com pose a risk of serious injury or death from tip-over and entrapment if not anchored to the wall. About 16,809 units are affected.

    Product
    EnHomee 9-Drawer Fabric Dressers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·26V476000·2026-07-23

    Forest River Recalls 2027 Travel Trailers with Incorrect Water Tank Labels

    Forest River is recalling 2027 travel trailers because the Federal Placard may list an incorrect fresh water tank capacity, which could lead to vehicle overloading.

    Product
    FOREST RIVER — FOREST RIVER SANDPIPER, SIERRA, SABRE, NO BOUNDARIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26637·2026-07-23

    OeyUoc Pool Drain Covers Recalled for Entrapment and Drowning Hazards

    OeyUoc white pool drain covers sold on Amazon violate safety standards and pose entrapment and drowning risks. About 404 units have been recalled; consumers should stop using them immediately.

    Product
    OeyUoc Pool Drain Covers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26635·2026-07-23

    Sili Factory Pull String Teething Toys recalled for choking hazard risk

    Aojieni Silicone is recalling about 5,918 Sili Factory Pull String Teething Toys because the silicone strings violate toy safety standards and can lodge in a child's throat, posing a serious choking risk.

    Product
    Sili Factory Pull String Teething Toys
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26639·2026-07-23

    Personalized Baby Bibs and Stroller Bags Recalled for Choking Hazard

    Peony Design has recalled personalized baby bibs and stroller bags sold online because snaps can detach, posing a choking risk to young children. The company is offering refunds.

    Product
    Personalized Baby Bibs and Stroller Bags
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0689-2026·2026-07-22

    Cleviprex Injectable Emulsion Recall Due to Sterility Assurance Concerns

    Chiesi USA, Inc. is recalling Cleviprex (clevidipine) injectable emulsion due to lack of assurance of sterility. The affected product is distributed nationwide.

    Product
    CLEVIPREX — CLEVIPREX (CLEVIPIDINE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2693-2026·2026-07-22

    ABIOMED Intro Kit Heart Pump Introducer Sheath Leakage Risk

    Abiomed, Inc. is recalling ABIOMED Intro Kit heart pump introducer sheaths due to potential leakage from under the sheath cap and along hub score lines. The manufacturing defects are not visually detectable by users.

    Product
    ABIOMED Intro Kit, 14Fr x 13 and 25 cm, PKGD, JP, Pump Set Code 0052-0023-JP; containing Introducer Product Code 0052-3025-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2686-2026·2026-07-22

    ABIOMED Impella CP Introducer Kit 14 Fr potentially defective sheath

    Abiomed, Inc. is recalling ABIOMED Impella CP Introducer Kit 14 Fr units worldwide due to potential introducer sheath leakage from under the sheath cap and along hub score lines. The manufacturing defect is not visually detectable.

    Product
    ABIOMED Impella CP Introducer Kit 14 Fr, 25 cm, Pump Set Code 0052-0039, containing Kit, 14Fr Introducer, 25cm, Long Taper, Introducer Product Code 0052-3053. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2682-2026·2026-07-22

    ABIOMED Impella CP Heart Pump Introducer Sheath Leakage Risk

    Abiomed is recalling the Impella CP heart pump set (87,277 units worldwide) due to potential leakage from the introducer sheath that cannot be visually detected by users. The defect affects the 14Fr and 23Fr introducers included in every pump set.

    Product
    ABIOMED Impella CP Set, Pump Set Code 0048-0003, containing BIOMED Impella Introducer, 14 Fr, 13 cm & 25 cm, Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2683-2026·2026-07-22

    ABIOMED Impella CP Introducer Kit 14Fr heart pump safety recall

    ABIOMED Impella CP Introducer Kit 14Fr is being recalled due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines. The manufacturing defect is not visually detectable by users.

    Product
    ABIOMED Impella CP Introducer Kit 14 Fr, 13 and 25 cm, Pump Set Code 1000550, containing Kit, 14Fr Introducer, 13cm&25cm, Sterile, Introducer Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2707-2026·2026-07-22

    T-Lok Bone Marrow Tray Kits Recalled for Sterility Testing Failure

    Argon Medical Devices is recalling T-Lok Bone Marrow Tray kits containing Lidocaine HCL Injection USP 1% because the kits did not meet sterility release criteria.

    Product
    T-Lok Bone Marrow Tray, REF: BMT1104STL; BMET1104TL; BMT1104CATL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2691-2026·2026-07-22

    ABIOMED Impella CP Heart Pump Set Introducer Sheath Leakage Risk

    ABIOMED Impella CP heart pump sets contain introducers that may leak from under the sheath cap and along hub score lines. These manufacturing defects are not visible during use.

    Product
    ABIOMED Impella CP Set, Pump Set Code 0048-0044; containing Introducer Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2684-2026·2026-07-22

    ABIOMED Introducer Kit 23 Fr heart pump accessory leakage risk

    Abiomed is recalling ABIOMED Introducer Kit 23 Fr due to potential sheath leakage from manufacturing defects. The leakage risk is not visually detectable and affects all current batches worldwide.

    Product
    ABIOMED Introducer Kit 23 Fr, 11 cm, Pump Set Code 1000441, containing Kit, 23Fr Introducer, 11cm, Sterile, Introducer Product Code 2000342. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2689-2026·2026-07-22

    ABIOMED Impella CP Heart Pump Set Introducer Sheath Leakage Risk

    ABIOMED is recalling Impella CP heart pump sets worldwide due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines in 14Fr and 23Fr introducers. The manufacturing defect is not visually detectable.

    Product
    ABIOMED Impella CP Set, Pump Set Code 0048-0014; containing Introducer Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2690-2026·2026-07-22

    Abiomed Impella CP Smart Assist Set Heart Pump Introducer Sheath Leakage

    Abiomed is recalling the Impella CP Smart Assist Set due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines in 14Fr and 23Fr introducers. These manufacturing issues are not visually detectable.

    Product
    ABIOMED Impella CP Smart Assist Set, JP, Pump Set Code 0048-0024-JP; containing Introducer Product Code 0052-3025-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide