ABIOMED Impella CP Introducer Kit 14 Fr potentially defective sheath
Abiomed, Inc. is recalling ABIOMED Impella CP Introducer Kit 14 Fr units worldwide due to potential introducer sheath leakage from under the sheath cap and along hub score lines. The manufacturing defect is not visually detectable.
The agency’s classification
FDA (Devices): Class I
Class I is a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: This is an FDA Class I recall of a medical device used in critical heart-support procedures. Class I recalls are defined as presenting serious adverse health consequences or death, and this sheath leakage defect in a heart pump component carries inherent risk of serious patient harm during use.
Plain-English summary
Abiomed, Inc. is recalling 1,223 units of the ABIOMED Impella CP Introducer Kit 14 Fr, 25 cm (Pump Set Code 0052-0039, Introducer Product Code 0052-3053) due to a potential for introducer sheath leakage from under the sheath cap and along the hub score lines. These manufacturing issues affect 14Fr and 23Fr Introducers and are not visually detectable by the user.
The defective Introducers are provided in every pump set and have been distributed worldwide, including throughout the US, Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, Japan, Mexico, Netherlands, Poland, Spain, Sweden, Switzerland, United Kingdom, and numerous other countries. All current batches in the field are affected.
Users who have received affected units should contact Abiomed, Inc. for additional information and guidance regarding their specific devices.
The recalled product
- Product
- ABIOMED Impella CP Introducer Kit 14 Fr, 25 cm, Pump Set Code 0052-0039, containing Kit, 14Fr Introducer, 25cm, Long Taper, Introducer Product Code 0052-3053. heart pump and accessories
- Manufacturer
- Abiomed, Inc.
- Affected units
- 1,223
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (3)
- Pump Set Code 0052-0039
- Introducer Product Code 0052-3053. GTIN: 00813502011715
- 00813502012736. All current batches in field.
Distribution
Part of a larger recall action
This product is one of 13 recalled by Abiomed, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 13 products in this recall →Related recalls
Same manufacturer · Abiomed, Inc.
See all →- HighAbiomed Recalls Automated Impella Controllers Due to Firmware and Software Defects
FDA (Devices) · 2026-09-30
- SevereAbiomed Recalls Impella Optical Controllers Due to Purge Sensor Defect
FDA (Devices) · 2026-09-23
- SevereAbiomed Recalls Impella Optical Controllers Due to Purge Flag Component Failure
FDA (Devices) · 2026-09-23
- SevereAbiomed Recalls Automated Impella Controllers Due to Purge Sensor Defect
FDA (Devices) · 2026-09-23
- SevereABIOMED Impella CP Heart Pump Introducer Sheath Leakage Risk
FDA (Devices) · 2026-07-22
Same hazard · sheath leakage
See all →- SevereABIOMED Impella CP Heart Pump Set Introducer Sheath Leakage Risk
FDA (Devices) · 2026-07-22
- SevereAbiomed Impella CP Introducer Kit heart pump accessory recall
FDA (Devices) · 2026-07-22
- SevereABIOMED Impella CP Heart Pump Set Introducer Sheath Leakage Risk
FDA (Devices) · 2026-07-22
- SevereABIOMED Intro Kit Heart Pump Introducer Sheath Leakage Risk
FDA (Devices) · 2026-07-22
- SevereAbiomed Impella CP Smart Assist Set Heart Pump Introducer Sheath Leakage
FDA (Devices) · 2026-07-22
Similar recalls
- SevereAbiomed Impella Introducer Kit Recalled Due to Potential Leakage
FDA (Devices) · 2026-07-22
- SevereAbiomed Introducer Kit for Impella Heart Pump Sheath Leak Risk
FDA (Devices) · 2026-07-22
- SevereAbiomed Impella Introducer Kit recalled for potential fluid leakage
FDA (Devices) · 2026-07-22
- SevereAbiomed Impella CP Introducer Kit recalled for thrombus formation risk
FDA (Devices) · 2026-07-01
- SevereAbiomed Impella CP Introducer Kit Recalled for Thrombus Risk
FDA (Devices) · 2026-07-01
- HighAbiomed Introducer Kit Sterile Barrier Compromise Due to Pouch Defect
FDA (Devices) · 2024-01-17