The Recall Desk

State

Missouri product recalls

73,885 recalls have nationwide distribution and so reach Missouri. 8,503 additional recalls listed Missouri specifically in their distribution scope.

What the numbers show

Total
8,503
Critical
1,339
Severe
2,205
Most recent
2026-11-11

Of the 8,503 recalls naming Missouri we have scored against our rubric, 1,339 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,205 (26%) are Severe.

These figures cover only the 8,503 recalls whose distribution notice names Missouri specifically. The 73,885 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

65351–65375 of 82388

  • ModerateFDA (Devices)·Z-1623-2014·2014-05-28

    Hospira Recalls Latex-Free Extension Sets Due to Packaging Seal Defect

    Hospira is recalling specific latex-free extension sets because the Tyvek cover may not be completely sealed, potentially compromising the sterile package.

    Product
    LATEX-FREE; EXTENSION SET; For Bladder Irrigation or Urinary Drainage, Compatible with T-U-R FLOW-POUCH RESERVOIR, list 6542, 71 inch (180 cm) Nominal Length; List No. 4693-01; single use; Hospira Product Usage: Bladder irrigation or urinary drainage
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1622-2014·2014-05-28

    Siemens syngo Imaging XS Software Recall Due to Data Deletion Risk

    Siemens Medical Solutions is recalling 64 syngo Imaging XS systems because a software change may have caused the deletion of archived medical images.

    Product
    syngo Imaging XS Syngo Imaging XS is a Picture Archiving and Communication System (PACS) intended to display, process, read, report, communicate, distribute, store and archive digital medical images. It supports the physician in diagnosis and treatment planning. Syngo Imaging…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1629-2014·2014-05-28

    Anspach Irrigation Clip 40 Recalled Due to Incorrect Assembly

    The Anspach Effort, Inc. is recalling 150 Anspach Irrigation Clip 40 units because they were assembled with incorrect, smaller clips.

    Product
    Anspach Irrigation Clip 40 Product Usage: Irrigation clips provide a method of supplying controlled, cooling irrigation during cutting, shaping, and removal of bone, including bones of the skull and spine.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1631-2014·2014-05-28

    SCM True Air Technologies Recalls ECATS E 850 Bariatric Beds

    SCM True Air Technologies is recalling 48 ECATS E 850 Bariatric Beds due to manufacturing documentation and vendor approval failures.

    Product
    ECATS E 850 Bariatric Bed, True Air Technologies, Inc.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-1347-2014·2014-05-28

    Oasis Tears Lubricant Eye Drops Recalled for Missing Bottle Labels

    Oasis Medical Inc. is recalling 10,549 bottles of Oasis Tears Lubricant Eye Drops because the label on the immediate bottle is missing.

    Product
    Oasis TEARS, Lubricant Eye Drops, 10mL/0.3 fl. oz. Bottle, OTC Only. Distributed by: OASIS, OASIS Medical, Inc., Glendora, CA 91741. UPC: 8 54819 00002 3.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V281000·2014-05-27

    Mitsubishi Recalls 2014 Lancer Models for Power Steering Tube Clearance Issue

    Mitsubishi is recalling 2014 Lancer Evolution and Ralliart vehicles because insufficient clearance between the power steering tube and crossmember brace may cause fluid leaks, increasing crash and fire risks.

    Product
    MITSUBISHI — MITSUBISHI LANCER EVOLUTION, LANCER RALLIART
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V280000·2014-05-27

    Lotus Recalls 2008-2011 Models Due to Oil Cooler Hose Defect

    Lotus is recalling 860 Elise, Exige, and Evora vehicles because the oil cooler hose may detach, posing fire and crash risks.

    Product
    LOTUS — LOTUS EXIGE, ELISE, EVORA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·14V279000·2014-05-27

    Ford E-150 wheelchair lift latch defect recall

    Mobility Specialists is recalling 2007-2008 Ford E-150 vans with wheelchair lifts where latches may fail, risking occupant falls.

    Product
    FORD — FORD E-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V276000·2014-05-23

    Van Hool C2045 Coaches Recalled for Electrical Fire Risk

    Van Hool is recalling 2004, 2006, and 2013 C2045 coaches because a battery equalizer component may conduct electricity when heated, increasing fire risk.

    Product
    VAN HOOL — VAN HOOL C2045
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V288000·2014-05-23

    Starcraft Recalls 2014 Trailers Due to Brittle Frame Spring Hangers

    Starcraft is recalling 49 model year 2014 trailers because brittle frame spring hangers may fracture, potentially causing loss of control and increasing crash risk.

    Product
    STARCRAFT — STARCRAFT AR-ONE, TRAVEL STAR EXP, AUTUMN RIDGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V278000·2014-05-23

    Suzuki Recalls 2014 DL650A V-Strom Motorcycles for Drive Chain Defect

    Suzuki is recalling 103 model year 2014 DL650A V-Strom motorcycles because a drive chain link may not have been riveted, which could cause the chain to come off and increase crash risk.

    Product
    SUZUKI — SUZUKI V-STROM 650
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V270000·2014-05-22

    Lexus Recalls 2013 GS 350 for Brake Pedal Switch Failure

    Toyota is recalling 2013 Lexus GS 350 vehicles because a brake pedal switch may fail, causing the vehicle to brake without driver input and increasing crash risk.

    Product
    LEXUS — LEXUS GS 350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V271000·2014-05-22

    Tiffin Recalls 2008-2011 RVs for LED Clearance Light Fire Risk

    Tiffin Motorhomes is recalling specific 2008-2011 recreational vehicles because moisture in LED clearance lights may cause a short circuit, increasing the risk of a fire.

    Product
    TIFFIN — TIFFIN BUS, BREEZE, ZEPHYR, ALLEGRO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·14188·2014-05-22

    Office Depot Recalls Gibson Leather Task Chairs Due to Fall Hazard

    Office Depot is recalling Gibson Leather Task Chairs because the seat plate weld can break, posing a fall hazard. About 1.4 million chairs were sold.

    Product
    Office Depot® Gibson Leather Task Chairs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V273000·2014-05-22

    Toyota Recalls 2004-2011 Siennas for Corroded Spare Tire Carrier Cable

    Toyota is recalling 2004-2011 Siennas in specific states because the spare tire carrier cable may corrode from road salt, risking the tire falling off and causing a crash.

    Product
    TOYOTA — TOYOTA SIENNA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V275000·2014-05-22

    Great Dane Recalls 2015 Dry Freight Semi-Trailers for Missing Weld

    Great Dane is recalling 2015 Dry Freight Semi-Trailers because a missing weld could cause trailer separation and increase crash risk.

    Product
    GREAT DANE — GREAT DANE DRY FREIGHT SEMI-TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·14V274000·2014-05-22

    Toyota Recalls 2014 Highlanders Due to Second Row Seat Locking Defect

    Toyota is recalling 231 model year 2014 Highlanders because the second row right-hand seat may not fully lock into the track, increasing injury risk in a crash.

    Product
    TOYOTA — TOYOTA HIGHLANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·14189·2014-05-22

    Lakeshore Bristle Builders for Toddlers Recalled Due to Choking Hazard

    Lakeshore Learning Materials is recalling Bristle Builders for Toddlers play sets because animal figure bases can detach, posing a choking hazard to young children.

    Product
    Lakeshore Bristle Builders® for Toddlers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·14V272000·2014-05-22

    Toyota Recalls 2014 Highlanders Due to Air Bag Software Error

    Toyota is recalling 2014 Highlander and Highlander Hybrid vehicles because improper air bag software may fail to properly restrain larger front passengers in a crash.

    Product
    TOYOTA — TOYOTA HIGHLANDER HYBRID, HIGHLANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1322-2014·2014-05-21

    REUMOFAN PLUS Tablets Recalled for Undeclared Ingredients and Lack of Approval

    Pain Free By Nature is recalling REUMOFAN PLUS tablets because they were marketed without FDA approval and contain undeclared diclofenac and methocarbamol.

    Product
    REUMOFAN PLUS Tablets, 30 Tablet Bottles, OTC. Previene el cancer en los huesos, Nueva presentacion el original.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1318-2014·2014-05-21

    FDA Recalls Unapproved Saluta Reduced Glutathione Injection Powder

    Flawless Beauty LLC is recalling Saluta (reduced glutathione) Powder for Injection because it was marketed without an approved NDA/ANDA and is labeled for use as an antidote.

    Product
    Saluta (reduced glutathione) Powder for Injection, 600 mg/vial, packaged in 10 vials per box, Exclusively Distributed by: QAF Pharmaceuticals Inc. Philippines, Unit Unit 202 ECG Building, Multinational Avenue, Multinational Village, Parahaque City, Metro Manila Philippines…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1941-2014·2014-05-21

    Kroger Private Selection Ice Cream Recalled for Undeclared Egg Allergen

    Kroger is recalling Private Selection Chocolate Hazelnut Mascarpone Ice Cream because the label failed to declare eggs in the ingredient statement.

    Product
    Private Selection Chocolate Hazelnut Mascarpone Ice Cream, 16 fl oz lamented carton. Product labeled in part, "PRIVATE SELECTION" CHOCOLATE HAZELNUT MASCARPONE ICE CREAM chocolate covered hazelnuts folded into creamy mascarpone ice cream***INGREDIENTS: ICE CREAM MILK, CREAM…
    Category
    Food
    Distribution
    31 states