The Recall Desk

State

Maine product recalls

20,199 recalls have nationwide distribution and so reach Maine. 0 additional recalls listed Maine specifically in their distribution scope.

About recalls in Maine

Most US product recalls have nationwide distribution — the manufacturer ships into every state and the recall sweeps the same way. We include those in this listing because they affect Maine consumers even though the source notice doesn’t name the state. State-specific recalls are usually for products with regional distribution (a regional dairy, a local store brand) or where the agency was able to narrow the affected shipments to specific destinations.

If you’re checking whether a recall affects your purchase, the recall detail page lists the exact production lot codes, UPCs, and best-by dates. Match those against your package — distribution scope is a starting filter, not the final answer.

9576–9600 of 20199

  • HighFDA (Devices)·Z-1401-2024·2024-04-10

    Cardiovascular Procedure Kits Recalled for Pressure Relief Valve Defect

    Terumo is recalling 20,533 cardiovascular procedure kits due to a pressure relief valve that opens at incorrect pressure (200-300 mmHg instead of 400 mmHg). The defect could cause myocardial tissue damage during cardiac surgery.

    Product
    Cardiovascular Procedure Kits that include High Crack Check Valve PN 205307A Part Number: 6375 16010 62974 65246 66312 66342 66388 66650 66852 70472 74307 74365 74366 74430 74475 74477 74502 74773 74873 75065 75157 75195 75409 75410 75473 75533 75534
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1435-2024·2024-04-10

    Centurion Surgical Hook Kits Recalled Due to Weak Seal

    Medline Industries is recalling 1,520 Centurion surgical hook kits worldwide due to weak seals that may compromise sterility. The seal defect may not be detectable by users.

    Product
    Centurion hook kits labeled as: a) STERILE SKIN HOOK FINE (EA3975F), Product Code 66660; b) STERILE SMALL 2 PRONG SKIN HOOK (25754), Product Code 67105; c) STERILE NEWS TRACH HOOK(83300), Product Code 67810; d) STERILE LILLIE EAR HOOK DELICATE 7", Product Code I68655
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1398-2024·2024-04-10

    BD Phoenix diagnostic panel recalled for drug cross-contamination

    Becton Dickinson recalls BD Phoenix NMIC-306 microbiology diagnostic panels due to confirmed drug cross-contamination that may lead to incorrect bacterial identification and delayed treatment.

    Product
    BD Phoenix NMIC-306 Panel is a self-inoculating (when used with a BD Phoenix Automated Microbiology System) polystyrene panel (tray) containing control wells and substrate wells with dried biochemical substrates that use traditional qualitative microbiology methods such as fermen
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1415-2024·2024-04-10

    Exactech Shoulder Implant Components Recalled for Inadequate Oxygen Barrier Packaging

    Exactech Equinoxe shoulder implant components (4,007 units) are recalled because their vacuum-sealed packaging lacks a required oxygen barrier layer, potentially allowing material degradation.

    Product
    Exactech Equinoxe CAGE GLENOID,POSTERIOR AUGMENT, CEMENTED, Right, Mates with: a) 38, 41, 44, 47 head, Small, Item Number 314-13-32, b) 41, 44, 47, 50, head, Medium, Item Number 314-13-33, c) 44, 47, 50, 53 head, Large, Item Number 314-13-34, d) 44, 47, 50, 53 head, Ext
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1407-2024·2024-04-10

    Exactech Equinoxe Shoulder Glenoid Components Recalled for Defective Packaging

    Exactech is recalling 985 shoulder implant components due to nonconforming packaging that lacks a required oxygen barrier layer. The vacuum bags do not meet packaging specifications.

    Product
    Exactech Equinoxe GLENOID, POSTERIOR AUGMENT,PEGGED, CEMENTED, 8o, RIGHT, Mates with: a) 38, 41, 44, 47 head, Small, Item Number 314-02-32, b) 41, 44, 47, 50 head, Medium, Item Number 314-02-33, c) 44, 47, 50, 53 head, Large, Item Number 314-02-34, d) 44, 47, 50, 53 he
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1437-2024·2024-04-10

    Medline Centurion Surgical Forceps Kits Recalled for Defective Seals

    Medline Industries recalls 274,410 units of Centurion and Medline branded surgical forceps kits for potentially weak seals that could compromise sterility and may not be detectable during use.

    Product
    Centurion Forcep kits labeled as: a) STERILE F/P SPLINTER FORCEP (SF6141), Product Code 66165; b) STERILE WEBSTER NEEDLEHOLDER, Product Code 66185; c) STERILE ADSON FORCEP SERR (598), Product Code 66195; d) STERILE DRESSING FORCEP SERR (DF6003), Product Code 66200; e) STERIL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1445-2024·2024-04-10

    Suture Removal and Staple Remover Kits Recalled for Weak Seal

    Medline Industries is recalling suture removal trays and staple remover kits due to weak seals that may compromise product sterility. Approximately 23,290 units were distributed in the US, Panama, and Canada.

    Product
    Centurion manual surgical kits labeled as: a) SUTURE REMOVAL TRAY, Product Code TRI55405; b) SUTURE REMOVAL SET, Product Code 60265 MEDLINE manual surgical kits labeled as: a) SUTURE REMOVAL TRAY, Product Code 60280; b) SUTURE REMOVAL TRAY, Product Code 86125; c) SUT
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1479-2024·2024-04-10

    ARCHITECT Anti-HCV Reagent Kit Recalled for False Positive Results

    Abbott GmbH is recalling ARCHITECT Anti-HCV Reagent Kit (7,219 units) due to falsely elevated test results when processed after certain other tests on the same instrument. The product was distributed nationwide.

    Product
    ARCHITECT Anti-HCV Reagent Kit, List Numbers: a) 1L79-25, b) 1L79-35
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0432-2024·2024-04-10

    Fentanyl Citrate Injectable Recalled for Lack of Sterility Assurance

    IntegraDose Compounding Services LLC is recalling 187 cassettes of fentanyl citrate 2,500 mcg/50mL due to leaking bags that compromise sterility. Lot 20231020FEN-1 was distributed nationwide and expired April 17, 2024.

    Product
    fentaNYL Citrate 2,500 mcg/50mL in Sterile Water, 50 mL CADD for Injection, IntegraDose Compounding Services, LLC, 719 Kasota Ave SE, Minneapolis, MN. NDC 71139-6030-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1433-2024·2024-04-10

    Centurion Ear Speculum Sets Recalled for Weak Seal and Sterility Risk

    Medline Industries is recalling Centurion ear speculum sets due to weak seals that could compromise sterility. The defect may not be detectable by users and could allow contamination if the seal fails.

    Product
    Centurion STERILE ROUND EAR SPECULUM SET (3, 4, 5), Product Code I68505
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1425-2024·2024-04-10

    Exactech Shoulder Implant Liners Recalled for Defective Oxygen Barrier Packaging

    Exactech has recalled 591 units of Equinoxe Reverse Shoulder humeral liners because the packaging lacks a required oxygen barrier layer (EVOH). The nonconforming packaging may affect material integrity of these surgical implants.

    Product
    Exactech Equinoxe REVERSE SHOULDER,46mmConstrained Humeral Liner, a) +0mm, Item number 320-46-10, b) +2.5mm, Item Number 320-46-13; Shoulder Arthroplasty
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1447-2024·2024-04-10

    Centurion PICC Line Securement Kit Recalled for Weak Seal

    MEDLINE is recalling the Centurion PICC Line Securement Kit because its seal may be weak, potentially allowing sterility breach. Users may not be able to detect the weakness.

    Product
    Centurion PICC LINE SECUREMENT KIT, Product Code IVS565
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1434-2024·2024-04-10

    Medline Centurion Surgical Retractors Recalled for Potential Sterility Breach

    Medline is recalling Centurion surgical retractor kits (760 units) due to a weak seal that could compromise sterility if it fails. The weakness may not be detectable by users.

    Product
    Centurion retractor kits labeled as: a) STERILE 6-1/2" SENN RETRACTOR (ST7185), Product Code 66795; b) STERILE RAGNELL RETRACTOR (RR602), Product Code 67525; c) ST. SENN RETRACTOR 3 PRG BLUNT (ST7085), Product Code 37535
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1424-2024·2024-04-10

    Exactech Equinoxe Reverse Shoulder Humeral Liner Recall Due to Nonconforming Packaging

    Exactech is recalling 1,970 Equinoxe Reverse Shoulder humeral liners distributed nationwide and internationally due to nonconforming packaging that lacks required oxygen barrier protection. Affected devices may have compromised sterile barriers.

    Product
    Exactech Equinoxe REVERSE SHOULDER,46mm Humeral Liner, a) +0mm, Item number 320-46-00, b) +2.5mm, Item Number 320-46-03; Shoulder Arthroplasty
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1438-2024·2024-04-10

    Centurion Hemostat Kits Recalled Due to Weak Seal Sterility Breach Risk

    Medline Industries is recalling Centurion Hemostat kits because weak seals may allow sterile contents to become contaminated. The weak seal may not be apparent to users before the instrument is used.

    Product
    Centurion Hemostat kits labeled as: a) STERILE CURV KELLY HEMOSTAT, Product Code 65340; b) STERILE CURV MOSQUITO HEMOSTAT (MHS103), Product Code 66145; c) STERILE STRT KELLY HEMOSTAT (SK8039), Product Code 66170; d) STERILE CURV KELLY HEMOSTAT (CK8040), Product Code 66175
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1436-2024·2024-04-10

    Centurion Scalpel Handles Recalled Due to Weak Seal Risk

    Medline Industries is recalling Centurion scalpel handle kits due to weak seals that may compromise sterility. Users cannot always detect the defect.

    Product
    Centurion scalpel handle kits labeled as: a) STERILE # 3 SCALPEL HANDLE, Product Code 66825; b) STERILE PAS #3 BLADE HANDLE (BH3PAS), Product Code I68290
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1392-2024·2024-04-10

    X-Guide Handpiece Adaptor Sleeve defect affects fit on dental handpiece

    The X-Guide Handpiece Adaptor Sleeve 1 may have a manufacturing defect causing incorrect geometry that prevents proper fit on dental handpieces. Approximately 88 units are affected.

    Product
    X-Guide Handpiece Adaptor Sleeve 1, Model P010701
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1469-2024·2024-04-10

    Covidien Auto Suture blunt tip trocar recalled for seal disengagement

    Covidien recalls its Auto Suture blunt tip trocar (OMS-T10BTS) due to potential seal disengagement when mesh products are used incorrectly, affecting approximately 18,048 units worldwide.

    Product
    Covidien Auto Suture" Blunt Tip Trocar, Product Number OMS-T10BTS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1443-2024·2024-04-10

    Medline Centurion surgical kits recalled due to weak seal

    Medline Industries is recalling Centurion manual surgical kits because they may have weak seals that could compromise product sterility. The defect may not be noticeable to users before the kits are used.

    Product
    Centurion manual surgical kits labeled as: a) STERILE ALLIS TISS FCP 10", Product Code I68905; b) VAGINAL REPAIR KIT, Product Code MNS11505; c) PTCA ADD-ON KIT, Product Code MNS11545; d) INSTRUMENT SET, Product Code SUT21355
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1455-2024·2024-04-10

    Medline Alcohol Swabsticks Recalled for Weak Seal Compromising Sterility

    Medline is recalling alcohol swabsticks that may have weak seals potentially compromising product sterility. The defect may not be visible to users.

    Product
    MEDLINE SWABSTICKS ALCOHOL 3PK, Product code DYNDA2723
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1462-2024·2024-04-10

    Mobile X-ray System Structural Cable Defect Affects Safety Function

    Agfa DX-D 100 mobile X-ray systems have a structural cable defect in the support column that may prevent the safety mechanism from blocking the arm if the cable fails, potentially resulting in patient injury.

    Product
    Agfa DX-D 100 system-Digital Radiography mobile X-ray System. A mobile X-Ray modality, consisting of X-Ray console, generator, tube, digital detector, and workstation. This modality is used to generate projection X-Ray images of human patients. Models: 5411/ 050, A5411/ 0300
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1456-2024·2024-04-10

    ATTUNE AFFIXIUM Knee Implant Component Recalled for Incorrect Labeling

    DePuy Orthopaedics is recalling ATTUNE AFFIXIUM Cementless Fixed Bearing Knee implants (Size 6) due to incorrect labeling. The affected product includes Model No. 150621006 with Lot JA06A0252.

    Product
    ATTUNE AFFIXIUM Cementless Fixed Bearing Knee with 3DP Technology, Size 6. Component of the ATTUNE Total Knee Replacement System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1478-2024·2024-04-10

    Skull Anchor Key Defect Prevents CT Localizer Attachment

    Navinetics Inc. has recalled the NaviNetics Skull Anchor Key and Drill Kit (Lot 331401724) because the skull anchor key may fail to allow proper attachment of the CT localizer, preventing stereotactic imaging procedures.

    Product
    NaviNetics Skull Anchor Key and Drill Kit, REF NN1215
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1448-2024·2024-04-10

    Medline Centurion Manual Surgical Kits Recalled for Weak Seal Risk

    Medline Industries is recalling 1700 units of Centurion Manual surgical kits due to potential weak seals that could compromise sterility. The weak seal may not be detectable by users.

    Product
    Centurion Manual surgical kits labeled as: a) 15ML SAMPLING TUBE WITH CAP, Product Code 15MLVLCP; b) STERILE 9X12 RECLOSABLE BAG, Product Code MG912ST
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1403-2024·2024-04-10

    Exactech Equinoxe shoulder components recalled for nonconforming packaging

    Exactech is recalling 2,008 Equinoxe shoulder implant components due to packaging that lacks a required oxygen barrier layer. The defect does not meet product specifications.

    Product
    Exactech Equinoxe GLENOID,KEELED, CEMENTED, mates with 47, 50, 53 head, beta curvature, Sizes: a) Small, Item Number 314-01-12, b) Medium, Item Number 314-01-13, c) Large, Item Number 314-01-14, Shoulder Arthroplasty
    Category
    Medical Device
    Distribution
    Distributed nationwide