The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

5376–5400 of 15188

  • SevereNHTSA·21V384000·2021-05-25

    Life Line Recalls 2019-2020 RAM 5500 Vehicles for Brake Line Defect

    Life Line Emergency Vehicles is recalling 2019-2020 RAM 5500 vehicles because improperly routed rear brake lines may chafe and leak fluid, increasing crash risk.

    Product
    LIFELINE — LIFELINE RAM 5500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V385000·2021-05-25

    Van Hool Recalls 681 Buses Due to Fuel Rail Leak Risk

    Van Hool is recalling 681 buses because a sealing washer may not seat correctly, allowing the high-pressure fuel rail to leak and increasing fire risk.

    Product
    VAN HOOL — VAN HOOL CX45, CX35, TX45, TDX25
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V387000·2021-05-25

    2020 Tesla Model 3 brake caliper bolts may loosen and separate

    Tesla is recalling certain 2020 Model 3 vehicles because brake caliper bolts may loosen, causing the caliper to separate and lose tire pressure, increasing crash risk.

    Product
    TESLA — TESLA MODEL 3, MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V386000·2021-05-25

    Seagrave Fire Apparatus Recalls 2017-2020 Models Due to Fuel Leak Risk

    Seagrave is recalling 2017-2020 Marauder, Attacker, and Capitol vehicles because a sealing washer defect may cause high-pressure fuel leaks, increasing fire risk.

    Product
    SEAGRAVE — SEAGRAVE MARAUDER, ATTACKER, CAPITAL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V390000·2021-05-25

    2021 Ford F-Series trucks recalled for improper front wheel hub attachment

    Ford is recalling 17,616 of its 2021 F-Series trucks with dual rear wheels and front wheel hub extenders. The hub extenders may be improperly attached, risking wheel separation and crash.

    Product
    FORD — FORD F-450 SD, F-550 SD, F-350 SD, F-600 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V389000·2021-05-25

    Tesla Recalls Model 3 and Model Y for Seat Belt Fastener Defect

    Tesla is recalling 2018-2020 Model 3 and 2019-2021 Model Y vehicles because front seat belt fasteners may not be properly attached, increasing injury risk.

    Product
    TESLA — TESLA MODEL Y, MODEL 3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V381000·2021-05-24

    Ford Recalls 2021 F-150 Trucks Due to Driveshaft Assembly Defect

    Ford is recalling 2021 F-150 vehicles because improperly assembled driveshafts may separate, potentially causing loss of drive power or unintended movement.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V383000·2021-05-24

    Great Dane Recalls 2022 Champion Trailers Due to Brake Bolt Issue

    Great Dane is recalling 2022 Champion trailers because brake caliper bolts may loosen, reducing brake effectiveness and increasing crash risk.

    Product
    GREAT DANE — GREAT DANE CHAMPION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V379000·2021-05-24

    2021 Ford F-350 and F-450 Cracked Fifth Wheel Mounting Bracket Recall

    Ford is recalling certain 2021 F-350 SD and F-450 SD vehicles with fifth wheel left-hand mounting brackets that may be cracked. A cracked bracket could result in the fifth wheel detaching during towing, increasing crash risk.

    Product
    FORD — FORD F-450 SD, F-350 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V378000·2021-05-24

    2021 Forest River Sierra and Sandpiper trailers recalled for loose chassis bolts

    Forest River is recalling certain 2021 Sierra and Sandpiper trailers whose chassis bolts were improperly tightened. The trailers could detach from their chassis, increasing crash risk.

    Product
    FOREST RIVER — FOREST RIVER SANDPIPER, SIERRA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V376000·2021-05-24

    Ford Transit Connect 2013-2021 shifter cable bushing defect recall

    Ford is recalling 2013-2021 Transit Connect vehicles with 2.5L engines (approximately 192,080 units) because the shifter cable bushing may degrade or detach, preventing proper gear selection and causing unexpected vehicle movement or rollaway, increasing crash and injury risk.

    Product
    FORD — FORD TRANSIT CONNECT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V377000·2021-05-24

    2021 Ford Edge vehicles recalled for defective seatbelt retractors

    Ford is recalling certain 2021 Edge vehicles for a defective driver's seatbelt retractor pretensioner assembly that may fail to function during a crash. A faulty seatbelt increases injury risk in accidents.

    Product
    FORD — FORD EDGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V380000·2021-05-24

    Keystone Cougar Travel Trailer Frame Rails Recalled for Buckling Risk

    Keystone is recalling 2017-2021 Cougar travel trailers because the frame rails lack sufficient cross support and can buckle under side-load stress. Buckled frames can increase crash risk.

    Product
    KEYSTONE — KEYSTONE COUGAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V382000·2021-05-24

    Honda Motorcycles Recalled for Defective Rear Reflectors

    Honda is recalling certain 2020-2021 motorcycles because the rear reflector lens may not reflect brightly enough. This defect reduces visibility and increases the risk of crashes or injuries.

    Product
    HONDA — HONDA CBR500R, CMX300, CMX500, MONKEY125
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V375000·2021-05-21

    Rugged Mountain Custom RV K2 Recalled for Gas Leak Risk

    Tiny Idahomes is recalling 2019 Rugged Mountain Custom RV K2 trailers because a stove component may cause a continuous gas leak, increasing fire risk.

    Product
    RUGGED MOUNTAIN CUSTOM RV — RUGGED MOUNTAIN CUSTOM RV K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V374000·2021-05-21

    2021 Forest River Columbus Trailer Brakes May Fail Due to Wiring Defect

    Forest River is recalling 2021 Columbus Fifth Wheel trailers due to an incorrectly wired breakaway switch that may prevent the trailer brakes from activating, increasing the risk of crashes.

    Product
    FOREST RIVER — FOREST RIVER COLUMBUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21E047000·2021-05-21

    Lippert Recalls Hehr 6400 Series RV Windows Due to Adhesive Failure

    Lippert is recalling Hehr 6400 Series windows for recreational vehicles because the adhesive may fail, causing the vent to detach and increasing crash risk.

    Product
    EQUIPMENT:RECREATIONAL VEHICLE/TRAILER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V373000·2021-05-20

    2021 Nissan Armada Fuel Pump Module Replacement Recall

    Nissan is recalling 2020-2021 Armada and INFINITI QX80 vehicles with V8 engines due to fuel pump module defects. The impeller can swell and bind, causing fuel pump failure and potential engine stall, increasing crash risk.

    Product
    NISSAN — NISSAN, INFINITI ARMADA, QX80
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·21748·2021-05-20

    John Deere Recalls Gator Utility Vehicles Due to Crash Hazard

    John Deere is recalling about 90 Gator utility vehicles because a software error can cause the speedometer and safety systems to fail, posing a crash risk.

    Product
    John Deere XUV590 and XUV590 S4 Gator™ utility vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V372000·2021-05-20

    Newmar Motorhomes Recalled for Fuel Rail Seal Defect and Fire Risk

    Newmar is recalling 1,294 motorhomes from 2017-2022 due to a defective fuel rail sealing washer that could cause fuel leaks and increase fire risk. Dealers will inspect and replace the affected rails at no cost.

    Product
    NEWMAR — NEWMAR MOUNTAIN AIRE, DUTCH STAR, VENTANA, NEW AIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V366000·2021-05-19

    International and IC Bus commercial vehicles recalled for fuel rail assembly defect

    Navistar is recalling certain 2018-2021 International and IC Bus commercial vehicles due to a fuel rail assembly defect. A sealing washer may not seat correctly, allowing fuel leaks that could ignite.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS DURASTAR, WORKSTAR, HV, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V369000·2021-05-19

    2021–2022 Heavy-Duty Trucks Recalled for Loose Tie Rod Assembly Components

    Daimler Trucks North America is recalling certain 2021–2022 heavy-duty trucks including Freightliner and Western Star models due to potentially loose tie rod clamps. Loose or detached tie rod ends could cause steering loss and increase crash risk.

    Product
    FCCC — FCCC, WESTERN STAR, FREIGHTLINER XB CHASSIS, S2, MT CHASSIS, 5700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V367000·2021-05-19

    Navistar Recalls 2019-2021 IC Bus RE School Buses for Fuel Leak Risk

    Navistar is recalling 2019-2021 IC Bus RE School Buses because a sealing washer may not seat correctly, causing the high-pressure fuel rail to leak and increasing fire risk.

    Product
    IC BUS — IC BUS RESB
    Category
    Vehicle
    Distribution
    Distributed nationwide