Dexcom ONE+ iOS CGM App Software Defect Delayed Glucose Alerts
Dexcom, Inc. is recalling Dexcom ONE+ iOS CGM App versions 1.5.0 and 1.6.0 due to a software defect that can delay glucose alerts and notifications, risking delayed detection of low or high blood sugar events.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II recall of a medical device with a software defect that creates a risk of harm to users (missed detection of dangerous blood sugar events and delayed treatment decisions). The source text explicitly states no illnesses or injuries have been reported, placing it at the upper end of High severity under the rubric's criterion for "risk-of-harm products where injury has not yet been reported."
Plain-English summary
Dexcom, Inc. is recalling the Dexcom ONE+ iOS CGM App (Model SW14244, versions 1.5.0 and 1.6.0) distributed internationally, including to the United Kingdom, Australia, New Zealand, Canada, and other countries listed in the recall notice.
The recalled app contains a software defect in which a low-priority file input/output (I/O) check blocks the higher-priority thread responsible for processing estimated glucose values (EGVs) and trend arrows. When the app runs in the background, glucose notifications may queue up and then replay sequentially when the user brings the app to the foreground, causing the Glucose Compass to flicker through previous glucose readings. In more severe cases, the app may perceive signal loss and deploy signal loss mitigations.
This delay in glucose value and alert processing creates a risk that users may miss detection of hypoglycemic (low blood sugar) or hyperglycemic (high blood sugar) events, or make treatment decisions based on outdated glucose information.
Users of the affected app should check for and install any available software updates from Dexcom. For additional information or concerns, patients should contact their healthcare provider or Dexcom customer support.
The recalled product
- Product
- Brand Name: Dexcom ONE+ Continuous Glucose Monitoring System Product Name: Dexcom ONE+ iOS CGM App Model/Catalog Number: SW14244 Software Version: versions 1.5.0 and 1.6.0 Product Description: Dexcom ONE+ iOS CGM App Component: Dexcom ONE+ Continuous Glucose Monitoring…
- Manufacturer
- Dexcom, Inc.
- Affected units
- 70,212
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- Lot Code: SW14244 versions 1.5.0 and 1.6.0 - UDI-DI: 00386270004307
Distribution
Part of a larger recall action
This product is one of 3 recalled by Dexcom, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 3 products in this recall →Related recalls
Same manufacturer · Dexcom, Inc.
See all →- SevereDexcom G7 Continuous Glucose Monitoring System sensors recalled
FDA (Devices) · 2026-07-01
- HighDexcom G7 app defect may delay glucose readings and alerts
FDA (Devices) · 2026-05-20
- HighDexcom G7 CGM iOS App Software Defect Delays Glucose Alerts
FDA (Devices) · 2026-05-20
- CriticalGlucose monitoring app recalled because it can terminate and miss alerts
FDA (Devices) · 2025-11-05
- CriticalDexcom G7 iOS app recalled because sensor failure alerts do not appear
FDA (Devices) · 2025-09-10
Same hazard · software defect
See all →- ModerateBeckman Coulter Recalls DxC 500i Clinical Analyzer Modules Due to Software Error
FDA (Devices) · 2026-10-14
- HighPhilips Spectral CT Systems Recalled for Software Issues Affecting Safety
FDA (Devices) · 2026-10-14
- ModerateSteris HexaVue Focus Integration System Recalled for Patient Data Mismatch
FDA (Devices) · 2026-10-14
- ModerateUnited Imaging uMI Panvivo S PET/CT Systems Recalled for Software Defect
FDA (Devices) · 2026-10-07
- ModerateUnited Imaging uCT 550 CT Systems Recalled for Software Defect
FDA (Devices) · 2026-10-07
Similar recalls
- CriticalDexcom ONE+ iOS app recalled because sensor failed alerts do not appear
FDA (Devices) · 2025-09-10
- CriticalDexcom ONE+ Android app recalled over missing sensor failure alerts
FDA (Devices) · 2025-09-10
- CriticalDexcom G7 iOS app recalled because sensor failure alerts do not appear
FDA (Devices) · 2025-09-10
- CriticalGlucose monitor apps recalled because sensor failed alerts do not appear
FDA (Devices) · 2025-09-10
- CriticalGlucose monitoring app recalled because it can terminate and miss alerts
FDA (Devices) · 2025-11-05
- CriticalDexcom G7 watchOS app recalled because sensor failure alerts are missing
FDA (Devices) · 2025-09-10