Lisendo 880 Ultrasound Software displays incorrect cardiac valve measurements
Lisendo 880 Ultrasound Software versions V1.0–V4.1.3 may not display cardiac measurement results correctly for mitral valve assessments, affecting diagnostic accuracy.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: FDA Class II medical device with a measurement display error affecting diagnostic accuracy. No illnesses or injuries reported, but incorrect measurements present a potential risk of misdiagnosis, meeting the criterion for High severity in the rubric.
Plain-English summary
Lisendo 880 Ultrasound Software versions V1.0 through V4.1.3, used with Fujifilm transducers, does not display measurement results correctly for two cardiology functions: Mitral Regurgitation Flow (MR Flow) Measurement and Mitral Valve (MV) Measurement. This measurement display error affects the reliability of cardiac assessments performed with this software.
The software has been distributed nationwide in diagnostic ultrasound systems used in healthcare facilities. FujiFilm Healthcare Americas Corporation, the manufacturer, identified the measurement display defect and filed a Class II recall. The instruction manual also contains an error related to this issue.
Affected facilities using versions V1.0 through V4.1.3 should contact FujiFilm Healthcare Americas Corporation regarding corrective action or software updates to ensure accurate cardiac measurements.
The recalled product
- Product
- Lisendo 880 Ultrasound Software Version: V1.0 through V4.1.3
- Manufacturer
- FujiFilm Healthcare Americas Corporation
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- Serial Numbers/UDI: 20514657 (01)04562122958868(11)161220(21)20514657
- 20659147 (01)04562122958868(11)20181124(21)20659147
- 20659148 (01)04562122958868(11)20181124(21)20659148
- 20659149 (01)04562122958868(11)20181124(21)20659149
- 20659150 (01)04562122958868(11)20181124(21)20659150
- 20659153 (01)04562122958868(11)20181126(21)20659153
- 20659154 (01)04562122958868(11)20181126(21)20659154
- 20659155 (01)04562122958868(11)20181126(21)20659155
- 20659156 (01)04562122958868(11)20181126(21)20659156
- 205G0225 (01)04562122958868(11)20170418(21)205G0225
- 205G0226 (01)04562122958868(11)20170424(21)205G0226
- 205P2146 (01)04562122958868(11)20170615(21)205P2146
- 205P2147 (01)04562122958868(11)20170615(21)205P2147
- 205P2148 (01)04562122958868(11)20170615(21)205P2148
- 205P2149 (01)04562122958868(11)20170615(21)205P2149
- 205Q0809 (01)04562122958868(11)20170707(21)205Q0809
- 205Q0810 (01)04562122958868(11)20170707(21)205Q0810
- 205Q0812 (01)04562122958868(11)20170707(21)205Q0812
- 205Q0815 (01)04562122958868(11)20171006(21)205Q0815
- 205T7139 (01)04562122958868(11)20171006(21)205T7139
Distribution
Distributed nationwide across the United States.
Part of a larger recall action
This product is one of 3 recalled by FujiFilm Healthcare Americas Corporation under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 3 products in this recall →Related recalls
Same manufacturer · FujiFilm Healthcare Americas Corporation
See all →- ModerateFujifilm Synapse PACS Software Recalled for Inaccurate Ruler Measurements
FDA (Devices) · 2026-09-02
- HighX-ray systems recalled over welded contactor contacts that may overheat
FDA (Devices) · 2026-02-11
- HighRadiography suites recalled because X-ray tube mounting shaft may break
FDA (Devices) · 2025-10-15
- ModerateASPIRE Cristalle mammography systems shipped with unapproved slabbing software enabled
FDA (Devices) · 2025-08-06
- HighSynapse PACS Software incorrect patient age calculation for infants
FDA (Devices) · 2025-03-26
Same hazard · measurement error
See all →- ModeratePhilips MR 7700 MRE Upgrade MRI Equipment Stiffness Value Error Risk
FDA (Devices) · 2026-05-06
- HighPhilips Evolution Upgrade 1.5T MRI Stiffness Calculation Error
FDA (Devices) · 2026-05-06
- ModeratePhilips SmartPath to Ingenia Elition X MR Elastography Stiffness Value Errors
FDA (Devices) · 2026-05-06
- ModeratePhilips Ingenia Ambition X MRI Systems Stiffness Value Error Recall
FDA (Devices) · 2026-05-06
- ModeratePhilips Achieva 1.5T MRI System MRE Protocol Parameter Error Recall
FDA (Devices) · 2026-05-06
Similar recalls
- HighArietta 65 Ultrasound Software: Calculation Error in EROA Diagnostic Measurements
FDA (Devices) · 2021-11-10
- HighACUSON Redwood 1.0 ultrasound displays incorrect cardiac measurement values
FDA (Devices) · 2024-05-01
- HighACUSON Juniper ultrasound systems display incorrect cardiac measurements
FDA (Devices) · 2024-05-01
- HighPhilips QLAB Software Recall for Incorrect Ejection Fraction Calculations
FDA (Devices) · 2014-12-24
- HighFujifilm Synapse Cardiovascular Software Recalled for Inaccurate EMR Measurements
FDA (Devices) · 2015-05-20
- HighPhilips Q-Station Software Recalled for Potential Incorrect Cardiac Measurements
FDA (Devices) · 2014-12-24