197 recalls in our database name Keystone RV Company as the manufacturing or recalling firm.

What the numbers show

Total
197
Critical
0
Severe
84
Most recent
2026-05-18

Of the 197 recalls from Keystone RV Company we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 84 (43%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

176–197 of 197

  • SevereNHTSA·11V322000·2011-06-13

    Keystone Cougar High Country Travel Trailer Axle Recall

    Keystone is recalling 2011-2012 Cougar High Country travel trailers because 4,400-pound axles were installed instead of 5,200-pound axles, creating a risk of axle failure.

    Product
    KEYSTONE — KEYSTONE COUGAR HIGH COUNTRY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11V317000·2011-06-08

    Keystone Recalls 2012 Residence Travel Trailers Due to Wiring Defect

    Keystone RV Company is recalling certain 2012 Residence travel trailers because incorrect wiring connectors on the slide room ceiling light could cause a loose connection, increasing the risk of fire, property damage, or personal injury.

    Product
    KEYSTONE — KEYSTONE RESIDENCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·11V094000·2011-02-10

    Keystone Recalls 2011 Laredo and Cougar Travel Trailers for Axle Defect

    Keystone RV is recalling 2011 Laredo and Cougar travel trailers because axles are installed backwards, reducing braking torque and shortening brake lining life.

    Product
    KEYSTONE — KEYSTONE COUGAR, LAREDO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·11V078000·2011-02-03

    Keystone Recalls 2011 Raptor RVs Due to Water Line Misconnection

    Keystone RV Company is recalling certain 2011 Raptor recreational vehicles because the fresh water line may be connected to the black waste water tank, risking contamination.

    Product
    KEYSTONE — KEYSTONE RAPTOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11V064000·2011-01-26

    Keystone Recalls 2011 RVs Due to Propane Leak Risk in Ovens

    Keystone is recalling 2011 Avalanche, Laredo, and Springdale recreational vehicles because a fracture in the oven gas line could cause a propane leak.

    Product
    KEYSTONE — KEYSTONE AVALANCHE, LAREDO, SPRINGDALE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·11V027000·2011-01-19

    Keystone Montana Trailers Recalled for Propane Hose Fire Risk

    Keystone is recalling certain Montana and Montana Big Sky trailers because the propane hose may contact the tire and become damaged, posing a fire or explosion risk.

    Product
    KEYSTONE — KEYSTONE MONTANA, MONTANA-BIG SKY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11V002000·2011-01-04

    Keystone Recalls 2010-2011 Travel Trailers Due to Hitch Coupler Defect

    Keystone is recalling 2010-2011 Laredo, Cougar, and Outback travel trailers because a hitch coupler defect may increase the risk of trailer separation.

    Product
    KEYSTONE — KEYSTONE COUGAR, OUTBACK, LAREDO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V606000·2010-12-01

    Keystone Recalls 2011 Travel Trailers Due to Circuit Breaker Fire Risk

    Keystone is recalling 2011 Fuzion, Cougar, and Sprinter travel trailers because defective circuit breakers may cause electrical fires, property damage, or injury.

    Product
    KEYSTONE — KEYSTONE FUZION, COUGAR, SPRINTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V594000·2010-11-23

    Keystone Recalls Fifth Wheel Trailers Due to Electrical Fire Risk

    Keystone RV Company is recalling specific fifth wheel trailers because an improperly installed transfer switch may cause electrical connections to overheat and start a fire.

    Product
    KEYSTONE — KEYSTONE AVALANCHE, EVEREST, FUZION, MONTANA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V597000·2010-11-23

    Keystone Recalls 2011 Travel Trailers Due to Wheel Weld Defects

    Keystone is recalling 2011 travel trailers with specific steel wheels due to inadequate weld penetration that could cause wheel failure.

    Product
    KEYSTONE — KEYSTONE COUGAR, SPRINTER, LAREDO, OUTBACK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V587000·2010-11-17

    Keystone Recalls RVs With Norcold Refrigerators Due to Fire Risk

    Keystone is recalling certain recreational vehicles and fifth wheel trailers equipped with 1200-series Norcold refrigerators because the safety shut-off mechanism may not prevent a fire.

    Product
    KEYSTONE — KEYSTONE MONTANA HIGH COUNTRY, MONTANA-BIG SKY, RAPTOR, FUZION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V570000·2010-11-11

    Keystone Montana Fifth Wheel Trailer Frame Recall

    Keystone is recalling 2010-2011 Montana fifth wheel trailers due to frame flexing that can cause damage or crashes.

    Product
    KEYSTONE — KEYSTONE MONTANA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V521000·2010-10-27

    Keystone RV Recall for Fire Risk in Electric Fireplace Remote Controls

    Keystone is recalling certain Montana and Everest RVs because the plug-in remote control receiver for electric fireplaces can overheat and cause a fire.

    Product
    KEYSTONE — KEYSTONE MONTANA-BIG SKY, MONTANA, EVEREST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V478000·2010-10-05

    Keystone Recalls 2011 RVs Due to Propane Leak Risk in Ovens

    Keystone is recalling 2011 recreational vehicles equipped with Atwood 35 Series range ovens due to a potential propane gas leak that could cause fire or explosion.

    Product
    KEYSTONE — KEYSTONE SPRINGDALE, HORNET, OUTBACK, PASSPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V413000·2010-09-16

    Keystone Recalls 2011 Fifth Wheel Trailers Due to Axle Spindle Cracks

    Keystone is recalling 322 specific 2011 fifth wheel trailers because cracks in the axle spindle weld could cause the wheel to detach, increasing crash risk.

    Product
    KEYSTONE — KEYSTONE MOUNTAINEER, ALPINE, AVALANCHE, FUZION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V241000·2010-06-07

    Keystone Recalls 2010-2011 Residence Travel Trailers for Electrical Defect

    Keystone RV Company is recalling 2010-2011 Residence travel trailers because an incorrect 30-amp breaker on the washer/dryer circuit increases the risk of property damage and personal injury.

    Product
    KEYSTONE — KEYSTONE RESIDENCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·10V239000·2010-06-03

    Keystone Cougar High Country Fifth Wheels Recalled for Missing Egress Window

    Keystone RV is recalling certain 2010-2011 Cougar High Country fifth wheels because the rear bedroom is missing an egress window, increasing injury risk during emergency evacuations.

    Product
    KEYSTONE — KEYSTONE COUGAR HIGH COUNTRY
    Category
    Vehicle
    Distribution
    Distributed nationwide