The Recall Desk

Manufacturer

General Motors, LLC

498 recalls in our database name General Motors, LLC as the manufacturing or recalling firm.

What the numbers show

Total
498
Critical
3
Severe
257
Most recent
2026-10-21

Of the 498 recalls from General Motors, LLC we have scored against our rubric, 3 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 257 (52%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

176–200 of 498

  • HighNHTSA·21V245000·2021-04-08

    GM Recalls 2014-2016 Trucks and SUVs for Seat Belt Cable Defect

    General Motors is recalling specific 2014-2016 Chevrolet and GMC vehicles because a driver's seat belt cable may break, reducing safety protection.

    Product
    CHEVROLET — CHEVROLET, GMC SILVERADO 1500, SIERRA 1500, TAHOE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V210000·2021-03-25

    2021 Chevrolet Tahoe seat belt latch may be inaccessible

    GM is recalling certain 2021 Chevrolet Tahoe vehicles because the second-row center seat belt latch may be trapped beneath the trim bezel. Passengers cannot use this seat belt, increasing injury risk in a crash.

    Product
    CHEVROLET — CHEVROLET TAHOE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V213000·2021-03-25

    GM Recalls 2015 Chevrolet Colorado and GMC Canyon for Steering Defect

    General Motors is recalling 2015 Chevrolet Colorado and GMC Canyon vehicles because a poor electrical connection may cause loss of power steering, increasing crash risk.

    Product
    CHEVROLET — CHEVROLET, GMC COLORADO, CANYON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V211000·2021-03-25

    Chevrolet Camaro 2017-2021 Air Bag Emblem Separation Recall

    General Motors is recalling certain 2017-2021 Chevrolet Camaro vehicles because the plastic 'Camaro' emblem on the steering wheel air bag cover may separate during air bag deployment, creating a projectile hazard.

    Product
    CHEVROLET — CHEVROLET CAMARO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V189000·2021-03-18

    GM Recalls 2021 Chevrolet Express and GMC Savana for Fire Risk

    General Motors is recalling 2021 Chevrolet Express and GMC Savana vans with 6.6L engines because a battery cable defect may cause a short circuit and fire.

    Product
    CHEVROLET — CHEVROLET, GMC EXPRESS, SAVANA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V190000·2021-03-18

    Damaged Third-Row Seat Belts in 2021 GM Full-Size SUVs

    General Motors is recalling 2021 full-size SUVs because third-row seat belts may be entrapped or misrouted behind the seat-folding mechanism, potentially becoming damaged. A damaged seat belt could break during a crash, increasing the risk of occupant injury.

    Product
    GMC — GMC, CADILLAC, CHEVROLET YUKON, ESCALADE, SUBURBAN, ESCALADE ESV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V188000·2021-03-18

    Chevrolet 2021 Camaro Axle Shaft Separation Defect Recall

    General Motors is recalling certain 2021 Chevrolet Camaro vehicles because the left or right axle shaft may be missing a retaining ring, which could separate during driving and cause loss of power, increasing crash risk.

    Product
    CHEVROLET — CHEVROLET CAMARO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V115000·2021-02-25

    GM Recalls 33,838 Vehicles Due to Over-Cured Continental Tires

    General Motors is recalling 33,838 vehicles equipped with over-cured Continental tires that may develop sidewall breaks or belt separation, increasing crash risk.

    Product
    CHEVROLET — CHEVROLET, GMC, CADILLAC EXPRESS, SIERRA 1500, SAVANA, YUKON XL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V064000·2021-02-11

    2021 Chevrolet Tahoe Fuel Tank May Leak and Cause Fire

    General Motors is recalling 2021 Chevrolet Tahoe and GMC Yukon vehicles because fuel tank assemblies may be missing adhesive, which could result in fuel leaks and fire risk. Dealers will replace the fuel tank free of charge.

    Product
    CHEVROLET — CHEVROLET, GMC TAHOE, YUKON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalNHTSA·21V050000·2021-02-05

    GM Recalls Trucks and SUVs for Airbag Inflator Explosion Risk

    General Motors is recalling specific 2007-2011 trucks and SUVs because the front passenger airbag inflators may explode due to humidity, posing a risk of serious injury or death.

    Product
    GMC — GMC, CHEVROLET, CADILLAC SIERRA 3500, YUKON, TAHOE, YUKON XL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalNHTSA·21V051000·2021-02-05

    GM Recalls 2012 Trucks and SUVs for Airbag Inflator Defect

    General Motors is recalling 2012 Chevrolet, GMC, and Cadillac vehicles because the front passenger airbag inflators may explode, posing a risk of serious injury or death.

    Product
    CHEVROLET — CHEVROLET, GMC, CADILLAC SILVERADO 1500, SILVERADO 3500, YUKON, ESCALADE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalNHTSA·21V053000·2021-02-05

    GM Recalls 2009-2013 Trucks and SUVs for Airbag Inflator Defect

    General Motors is recalling specific 2009-2013 Chevrolet, GMC, and Cadillac vehicles because the front passenger airbag inflator may explode, sending metal fragments into the cabin.

    Product
    CHEVROLET — CHEVROLET, GMC, CADILLAC TAHOE, YUKON XL, SIERRA 1500, ESCALADE ESV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V052000·2021-02-05

    GM Recalls 2007-2009 Trucks and SUVs for Airbag Inflator Defect

    General Motors is recalling specific 2007-2009 Chevrolet, Cadillac, and GMC vehicles because the front passenger airbag inflators may explode, posing a risk of serious injury or death.

    Product
    CHEVROLET — CHEVROLET, CADILLAC, GMC SUBURBAN, ESCALADE ESV, ESCALADE EXT, AVALANCHE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V054000·2021-02-05

    GM Recalls 2010-2014 Trucks and SUVs for Airbag Inflator Defect

    General Motors is recalling specific 2010-2014 Cadillac, Chevrolet, and GMC vehicles because the front passenger airbag inflators may explode due to propellant degradation.

    Product
    CADILLAC — CADILLAC, CHEVROLET, GMC ESCALADE EXT, SUBURBAN, TAHOE, SIERRA 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V811000·2020-12-23

    GM Recalls Bolt EV and Other Vehicles for Seat Belt Attachment Defect

    General Motors is recalling multiple 2020-2021 vehicles due to incorrect bolts used to secure seat belts. Improperly fastened seat belts may fail to properly restrain occupants in a crash.

    Product
    CHEVROLET — CHEVROLET, CADILLAC, GMC SUBURBAN, ESCALADE NA, COLORADO, SILVERADO 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V808000·2020-12-22

    GM Recalls 2020 Chevrolet Bolt EV for Brake Caliper Fracture Risk

    General Motors is recalling 2020 Chevrolet Bolt EV vehicles because a front left brake caliper may fracture, potentially reducing brake performance and increasing crash risk.

    Product
    CHEVROLET — CHEVROLET BOLT EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V764000·2020-12-21

    GM Recalls 2010-2013 Buick and Chevrolet Models for Rear Suspension Defect

    General Motors is recalling specific Buick and Chevrolet vehicles because excessive corrosion protection on rear toe links may cause them to fracture, increasing crash risk.

    Product
    BUICK — BUICK, CHEVROLET LACROSSE, REGAL, MALIBU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V792000·2020-12-17

    Chevrolet Silverado 1500 Front Seat Belt Brackets May Not Secure

    General Motors is recalling certain 2020 Chevrolet Silverado 1500 and other vehicles because front-row center seat belt brackets may not be properly secured to the seat frame, potentially preventing proper restraint in a crash.

    Product
    CHEVROLET — CHEVROLET, GMC SILVERADO 1500, SIERRA 2500, SILVERADO 3500, TAHOE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V790000·2020-12-17

    GM Recalls 2021 Cadillac Escalade for Seat Belt Light Visibility Issue

    General Motors is recalling 2021 Cadillac Escalade vehicles because the front passenger seat belt and airbag status lights may be invisible in daytime, increasing crash injury risk.

    Product
    CADILLAC — CADILLAC ESCALADE NA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V736000·2020-11-25

    GM Recalls 2015-2016 Silverado and Sierra Trucks for Air Bag Defect

    General Motors is recalling 2015-2016 Chevrolet Silverado and GMC Sierra trucks because the roof-rail air bag inflator end cap may detach, posing an injury risk.

    Product
    CHEVROLET — CHEVROLET, GMC SILVERADO 1500, SIERRA 1500, SIERRA 2500, SIERRA 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V735000·2020-11-25

    Front Seat Bolts May Not Be Installed Properly in 2021 Chevrolet Tahoe

    Front seat attachment bolts may not have been properly installed on certain 2021 Chevrolet Tahoe, Suburban, and GMC Yukon models. If loose or missing, the seats could move during a crash, increasing injury risk.

    Product
    GMC — GMC, CHEVROLET YUKON, YUKON XL, TAHOE, SUBURBAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V701000·2020-11-13

    Chevrolet Bolt EV Recalled Due to High Voltage Battery Fire Risk

    General Motors is recalling 2017-2019 Chevrolet Bolt EVs because the high voltage battery could catch fire when charged to full capacity, increasing the risk of injury.

    Product
    CHEVROLET — CHEVROLET BOLT EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V684000·2020-11-05

    2020 Chevrolet Silverado 1500 Overcured Tire Recall May Increase Crash Risk

    General Motors is recalling certain 2020 Chevrolet Silverado 1500 vehicles with overcured Continental tires that may experience sudden air loss or tread separation, increasing crash risk.

    Product
    GMC — GMC, CHEVROLET, BUICK ACADIA, TRAVERSE, ENCLAVE, XT5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V668000·2020-10-29

    GM Recalls Vehicles for Missing Start-Stop Accumulator Bolts

    General Motors is recalling specific 2018-2020 vehicles because missing bolts on the start/stop accumulator may cause transmission leaks, loss of propulsion, or fire.

    Product
    GMC — GMC, CHEVROLET, CADILLAC TERRAIN, CRUZE, EQUINOX, XT4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V650000·2020-10-22

    GM Recalls 2019-2020 Silverado and Sierra Trucks for Driveshaft Defect

    General Motors is recalling 2019-2020 Chevrolet Silverado and GMC Sierra trucks because a driveshaft joint may not be properly welded, risking separation and loss of propulsion.

    Product
    CHEVROLET — CHEVROLET, GMC SILVERADO 2500, SILVERADO 1500, SIERRA 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

General Motors

American multinational automotive company

Country
United States
Founded
1908

Official website

Source: Wikidata (Q81965), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.