The Recall Desk

Hazard

Loose Fasteners recalls

61 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
61
Critical
0
Severe
30
Most recent
2026-03-26

Of the 61 loose fasteners recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 30 (49%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all loose fasteners recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 61

  • SevereNHTSA·25V434000·2025-06-30

    Volkswagen chassis, brake and suspension bolts may be incorrectly tightened

    Volkswagen is recalling certain 2023-2025 Atlas, Atlas Cross Sport and 2023-2024 ID.4 vehicles because bolts on the chassis, brake system and suspension may not have been correctly tightened in manufacturing.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS CROSS SPORT, ID.4, ATLAS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·25V417000·2025-06-27

    Bowlus trailer manual omits hitch bolt retightening from maintenance schedule

    Bowlus is recalling certain trailers with an elongated hitch because the owner's manual does not include instructions to retighten the two hitch bolts in the maintenance schedule.

    Product
    BOWLUS — BOWLUS ENDLESS HIGHWAYS, TERRA FIRMA, VOLTERRA, RIVET
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V419000·2025-06-19

    Subaru Forester child seat anchor bolts may come loose

    Subaru is recalling certain 2025 Forester vehicles because the child seat anchor bolts may have been improperly tightened, allowing them to come loose.

    Product
    SUBARU — SUBARU FORESTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V371000·2025-06-03

    2025 Ford Explorer Brake Caliper Bolts May Be Improperly Secured

    Ford is recalling certain 2025 Explorer vehicles because front brake caliper bolts may not be properly secured, potentially affecting brake function. Dealers will inspect and repair the bolts at no cost.

    Product
    FORD — FORD EXPLORER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V266000·2025-04-22

    IC school bus driver seat belt anchor bolts may come loose

    International is recalling certain 2025-2026 IC CESB and 2025 EVSB school buses because the driver's seat belt anchor bolt may come loose, so the belt may not restrain the driver in a crash.

    Product
    IC BUS — IC BUS CESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V257000·2025-04-17

    Volvo truck idler gear can detach from the engine causing stall

    Volvo Trucks is recalling certain 2022-2025 VN and 2025 New VN trucks because improperly tightened idler gear bracket fasteners may allow the idler gear to detach from the engine.

    Product
    VOLVO — VOLVO VNL (4), VN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V183000·2025-03-25

    Keystone travel trailer patio latch screws can loosen during transit

    Keystone RV is recalling certain 2025 Kodiak 2900FKSP and 308BHSL travel trailers because the patio latch screws may loosen, causing the latch to detach during transit.

    Product
    KEYSTONE — KEYSTONE KODIAK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V109000·2025-02-21

    BMW X3 battery cable connection can overheat stalling the engine

    BMW is recalling certain 2025 X3 30 xDrive vehicles because the connection between the positive battery cable and the starter-generator may be improperly tightened and overheat.

    Product
    BMW — BMW X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V018000·2025-01-16

    Acura ZDX stabilizer bar bolts can loosen damaging high voltage cables

    Honda is recalling certain 2024 Acura ZDX vehicles because front passenger stabilizer bar bracket bolts may loosen and detach from the frame, damaging high voltage cables or battery coolant lines.

    Product
    ACURA — ACURA ZDX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V015000·2025-01-16

    GM electric pickup rear centre seat belt bolt may be loose

    General Motors is recalling certain 2024 Chevrolet Silverado EV and 2024-2025 GMC Sierra EV pickups because the bolt securing the rear centre seat belt to the seat structure may not be properly tightened.

    Product
    GMC — GMC, CHEVROLET SIERRA EV, SILVERADO EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3200-2024·2024-10-02

    MRI Scanner Loose Screws May Block Tabletop and Delay Diagnosis

    The Ingenia Elition X MRI device may have loose screws that interfere with the horizontal tabletop, potentially delaying patient diagnosis and causing anxiety during extended bore exposure.

    Product
    Ingenia Elition X- For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782151; 2) 782119; 3) 781358; 4) 782107; 5)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3199-2024·2024-10-02

    MRI Diagnostic Device Recalled for Loose Assembly Screws Blocking Equipment

    Philips Ingenia Elition S MRI machines (10 units) are recalled because assembly screws may come loose and interfere with the horizontal tabletop, potentially delaying diagnosis and causing patient anxiety.

    Product
    Ingenia Elition S -For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782150 2) 782106
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3198-2024·2024-10-02

    Philips Ingenia Ambition X MRI Scanner Recalled Due to Loose Screws

    Philips is recalling 63 units of the Ingenia Ambition X MRI scanner due to loose screws in the IRF carrier assembly that may block the imaging tabletop and potentially delay diagnosis.

    Product
    Ingenia Ambition X - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782109
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3201-2024·2024-10-02

    Philips MR 5300 MRI System Recalled for Loose Assembly Screws

    Philips is recalling 68 MR 5300 MRI diagnostic systems worldwide because loose screws in the RF carrier assembly could block equipment movement and delay patient diagnosis.

    Product
    MR 5300 - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V643000·2024-08-28

    Volkswagen ID.4 passenger airbag inflator fasteners may be loose

    Volkswagen is recalling certain 2023-2024 ID.4 vehicles because the fasteners securing the passenger frontal airbag inflator may be loose, so the airbag may not deploy as intended.

    Product
    VOLKSWAGEN — VOLKSWAGEN ID.4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V567000·2024-07-30

    Mack truck seat and belt anchorage bolts may be improperly tightened

    Mack is recalling certain 2024-2025 Anthem, Granite and Pinnacle vehicles with RollTek driver's seats because the seat pedestal and seat belt attachment may have been improperly tightened.

    Product
    MACK — MACK PINNACLE (PI/PN), ANTHEM (AN), PIONEER PR (4), GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V378000·2024-05-29

    Fifth wheel refrigerator fasteners can loosen and crack propane line

    Grand Design is recalling certain 2023 Solitude fifth wheels because loose or missing fasteners on the refrigerator cooling unit can allow movement that cracks the propane line.

    Product
    GRAND DESIGN — GRAND DESIGN SOLITUDE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V216000·2024-03-20

    LiveWire rear axle and shock joint nuts may not be tightened

    LiveWire is recalling certain 2024 S2 Del Mar motorcycles because the rear axle and lower shock joint nuts may not have been properly tightened. 165 units are affected.

    Product
    LIVEWIRE — LIVEWIRE S2 DEL MAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V824000·2023-12-07

    Altec Welder Equipment May Detach From Aerial Device Vehicles

    Altec is recalling certain 2021-2023 aerial devices with Bobcat welders that may be misaligned, allowing fasteners to loosen and the welder to detach, becoming a road hazard and increasing crash risk.

    Product
    ALTEC — ALTEC AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V725000·2023-10-26

    2023-2024 Nissan Z: Loose Fasteners May Prevent Pop-Up Hood Activation

    Certain 2023-2024 Nissan Z vehicles have loose fasteners in the front bumper reinforcement that may prevent the pop-up engine hood from activating, increasing injury risk in frontal pedestrian crashes. Dealers will tighten the fasteners free of charge.

    Product
    NISSAN — NISSAN Z
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V504000·2023-07-21

    Peterbilt and Kenworth trucks recalled for loose driveline fasteners

    PACCAR is recalling certain 2023-2024 Peterbilt and Kenworth trucks due to improperly applied thread-lock on driveline fasteners. Loose fasteners could allow the driveline to separate, increasing crash risk.

    Product
    KENWORTH — KENWORTH, PETERBILT T280, 536, 537, T480
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V441000·2023-06-23

    Volvo Trucks Recall for Loose Steering Gear Fasteners

    Volvo Trucks is recalling 2023-2024 VN, VHD, and VAH trucks because steering gear fasteners may not be properly tightened, risking loss of vehicle control. Dealers will tighten the fasteners at no cost to owners.

    Product
    VOLVO — VOLVO VAH, VHD, VN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V318000·2023-05-04

    2024 Entegra Vision motorhome brake caliper bolts may be loose

    Jayco is recalling 2024 Entegra Vision and related motorhomes due to rear brake caliper attachment bolts that may not be properly tightened. Loose bolts could damage the wheel or brake lines, reducing brake performance and increasing crash risk.

    Product
    JAYCO — JAYCO, ENTEGRA ALANTE, VISION XL, VISION, EMBLEM
    Category
    Vehicle
    Distribution
    Distributed nationwide