The Recall Desk

Category

Vehicle recalls

NHTSA recalls of passenger vehicles, motorcycles, tires, and child seats.

About vehicle recalls

Vehicle recalls in our database all come from NHTSA. They cover passenger cars, light trucks, SUVs, motorcycles, tires, child safety seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA Campaign Number (a string like 25V123000) and lists every make / model / year combination affected. We carry the full vehicle range so you can search by your own car.

The most common vehicle-recall categories are airbag and seatbelt failures (the consequence is non-deployment in a crash), fuel system defects with fire risk, steering or brake malfunctions, electrical defects in EVs that can cause battery thermal events, software bugs in driver-assist systems, and child-seat harness failures. Recalls for tires almost always relate to a tread-separation risk in a defined production date range.

Every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, with no expiration. If your vehicle has an open recall, your dealer is required to perform the remedy free of charge as long as the vehicle exists. If you're not sure whether your vehicle is affected, the VIN lookup decodes your specific vehicle and cross-references the NHTSA database directly.

4576–4600 of 15584

  • HighNHTSA·22V372000·2022-05-24

    E-One Recalls 2022 Fire Trucks Due to Lighting Failure Risk

    E-One Incorporated is recalling 2022 Commercial, Cyclone 2, Cyclone N, and Typhoon N fire trucks because a defective circuit board can cause vehicle lighting to fail.

    Product
    E-ONE — E-ONE CYCLONE N, CYCLONE II, COMMERCIAL, TYPHOON N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V373000·2022-05-24

    Spartan Fire Recalls Fire Trucks Due to Lighting Failure Risk

    Spartan Fire is recalling 2021-2023 fire trucks because a defective circuit board can cause lighting to fail, increasing crash risk.

    Product
    SPARTAN FIRE — SPARTAN FIRE METROSTAR, FC-94, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V369000·2022-05-23

    Navistar Recalls 2022-2023 IC Buses Due to Steering Wheel Defect

    Navistar is recalling 2022-2023 IC CE, RE, and 1300 FBC buses because the steering wheel retaining nut may be tightened incorrectly, allowing the wheel to detach.

    Product
    IC BUS — IC BUS RE, 1300 FBC, CE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V367000·2022-05-23

    School buses recalled for steering wheels that may loosen and detach

    Navistar is recalling certain 2022-2023 IC BUS school buses. The steering wheel retaining nut may have been tightened incorrectly, allowing the steering wheel to loosen or detach. Owners should not drive their vehicles until repaired.

    Product
    IC BUS — IC BUS CE, RESB, RE, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22E043000·2022-05-23

    Curt Retrac Maglatch Bracket Kits Recalled for Potential Fracture

    Lippert is recalling Curt Retrac Maglatch Bracket Kits for 2021 Kenworth and Peterbilt trucks because the metal may fracture, risking grill guard damage and crashes.

    Product
    STRUCTURE:BODY:BUMPERS:ACTIVE SHUTTERS/GRILL recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V368000·2022-05-23

    Audi Recalls 2022 A4, A6, and Q5 Models for Engine Control Unit Defect

    Volkswagen Group of America is recalling 2022 Audi A4, A6, and Q5 Sportback vehicles because a semiconductor in the engine control unit may short-circuit, causing the engine to stall and increasing crash risk.

    Product
    AUDI — AUDI A4, A6, Q5 SPORTBACK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V363000·2022-05-20

    Bravo Recalls 2021 Trailers Due to Improperly Welded Couplers

    Bravo Trailers is recalling 2021 Hero, Scout, and Star models because improperly welded couplers may cause the trailer to separate from the tow vehicle.

    Product
    BRAVO — BRAVO STAR, HERO, SCOUT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V362000·2022-05-20

    Isuzu Recalls 2022 FTR and FVR Trucks for Fuel Leak Risk

    Isuzu is recalling 2022 FTR and FVR trucks because a fuel system component may leak, increasing fire risk, or allow air intake, causing engine stalling.

    Product
    ISUZU — ISUZU FTR, FVR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V366000·2022-05-20

    Great Lakes Tandem Trailers Recalled for Improperly Welded Couplers

    Joe's Trailer Mfg. is recalling 2021-2022 Great Lakes Tandem 16', 18', and 20' trailers because improperly welded couplers may cause the trailer to separate from the tow vehicle.

    Product
    GREAT LAKES — GREAT LAKES TANDEM 16', TANDEM 20', TANDEM 18'
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V361000·2022-05-20

    2021-2022 Coachmen motorhomes recalled for cooktop gas leak risk

    Forest River is recalling 2021-2022 Coachmen motorhomes with defective cooktop burner valves that can develop gas leaks. The leaks pose a fire risk and will be remedied by free cooktop replacement.

    Product
    COACHMEN — COACHMEN BEYOND, GALLERIA, NOVA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V360000·2022-05-20

    Daimler Recalls 2019-2021 Sprinter Vehicles for eCall Software Defect

    Daimler Vans USA is recalling 2019-2021 Freightliner and Mercedes-Benz Sprinter vehicles because a software error may disable the emergency call system.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER METRIS, SPRINTER 1500, SPRINTER 2500, SPRINTER 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V364000·2022-05-20

    GM Recalls 2022 Chevrolet HD Trucks for Brake Fluid Leak Risk

    General Motors is recalling 2022 Chevrolet 4500HD, 5500HD, and 6500HD trucks because a brake line fitting may leak fluid, increasing stopping distance.

    Product
    CHEVROLET — CHEVROLET 6500HD, 5500HD, 4500HD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V365000·2022-05-20

    Mercedes-Benz Vehicles: Emergency Calling System Disabled by Software Error

    Mercedes-Benz USA is recalling certain 2017-2022 models after a communication module software error disabled the emergency eCall system. Owners can receive a free software update via over-the-air delivery or at a dealer.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, MERCEDES-MAYBACH GLE 350, GLS 600, AMG GT C, AMG GT S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V355000·2022-05-19

    2022 International CV Vehicles Brake Sensor Fitting May Cause Brake Failure

    Navistar is recalling certain 2022 International CV vehicles because the pressure sensor fitting on the brake line assembly may not be tightened correctly, potentially causing brake fluid loss and brake failure.

    Product
    INTERNATIONAL — INTERNATIONAL CV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V356000·2022-05-19

    Reiser Recalls 2022 Trailers Due to Improperly Welded Couplers

    Reiser is recalling 2022 WCH, LSA, LTA, L, SBS, and LATV trailers because improperly welded couplers may cause the trailer to separate from the tow vehicle.

    Product
    REISER — REISER LSA, L, LATV, SBS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V354000·2022-05-19

    Hyundai Elantra and Accent seat belt pretensioners may explode in crash

    Hyundai is recalling certain 2020-2022 Accent and 2021-2022 Elantra models due to seat belt pretensioners that may explode during a crash, potentially projecting metal fragments and injuring occupants. Dealers will secure them with a cap at no charge.

    Product
    HYUNDAI — HYUNDAI ELANTRA HYBRID, ELANTRA, ACCENT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V357000·2022-05-19

    Bigfoot Recalls 2022 Travel Trailers Due to Gas Leak Risk

    Bigfoot is recalling 2022 25B17FB travel trailers because damaged burner control valves may cause a gas leak, increasing the risk of fire.

    Product
    BIGFOOT — BIGFOOT 25B17FB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V359000·2022-05-19

    2022 Chevrolet Blazer driver's seat frame weld defect

    General Motors is recalling certain 2022 Chevrolet Blazer vehicles due to an improper weld in the driver's seat cushion frame that may fail to adequately restrain the driver in a crash.

    Product
    CHEVROLET — CHEVROLET, CADILLAC MALIBU, EQUINOX, XT4, BLAZER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V358000·2022-05-19

    Coach House motorhomes recalled for cooktop gas leak fire risk

    Coach House is recalling certain 2021-2022 Platinum, Platinum II, and Arriva motorhomes with cooktop burner control valves that may leak gas and increase fire risk. Dealers will replace the cooktop at no cost.

    Product
    COACH HOUSE — COACH HOUSE PLATINUM II, PLATINUM, ARRIVA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V350000·2022-05-18

    Oliver Travel Trailers Recall Elite Models Due to Gas Leak Risk

    Oliver Travel Trailers is recalling 2021-2022 Legacy Elite models because damaged burner control valves may cause a gas leak, increasing fire risk.

    Product
    OLIVER TRAVEL TRAILERS — OLIVER TRAVEL TRAILERS LEGACY ELITE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V352000·2022-05-18

    Can-Am Recalls 2015-2019 Spyder RT and F3 for Sprocket Defect

    Bombardier is recalling 2015-2019 Can-Am Spyder RT and F3 motorcycles because a defective front sprocket may wear prematurely, causing a loss of drive power and increasing crash risk.

    Product
    CAN-AM — CAN-AM SPYDER RT, SPYDER F3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V351000·2022-05-18

    2022 Lucid Air Display Wiring Harness May Disable Critical Safety Screens

    Lucid is recalling 2022 Air vehicles because the display wiring harness may not be secured properly, potentially disabling screens that show speedometer, gear selection, and warning lights.

    Product
    LUCID — LUCID AIR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V347000·2022-05-18

    Prevost Recalls X3-45 Commuter Vehicles Due to Rearview Mirror Defect

    Prevost is recalling 2020-2022 X3-45 Commuter vehicles because the right-side rearview mirror is positioned incorrectly, obstructing the driver's view and increasing crash risk.

    Product
    PREVOST — PREVOST X3-45 COMMUTER
    Category
    Vehicle
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.