The Recall Desk

Agency

National Highway Traffic Safety Administration

NHTSA oversees recalls of vehicles, tires, child seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA campaign number.

Visit the official NHTSA site →

About NHTSA recalls

NHTSA regulates the safety of every motor vehicle sold in the US plus tires, child seats, and motor-vehicle equipment. Recalls are coordinated under a numbering scheme called the NHTSA Campaign Number — a string like 25V123000 where the first two digits are the year, V is for vehicle (T is for tires, C for child seats, E for equipment), and the rest identifies the campaign. Every vehicle in our database can be looked up by VIN to check whether any active campaigns affect it.

NHTSA recalls are unusual in two ways. First, the cause is usually a defined defect or non-compliance with a Federal Motor Vehicle Safety Standard rather than a pathogen or contamination event — so 'severity' tracks the consequence of the defect (does the airbag fail to deploy, does the steering lose assist, does the fuel tank leak) rather than reported illnesses. Second, every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, for as long as the vehicle is on the road. There's no expiration on a NHTSA campaign.

We enrich every recall with the full make / model / year-range affected so you can see at a glance whether your vehicle is in scope. If you're not sure, the VIN lookup decodes your specific vehicle and cross-references the database. The remedy is always free — usually a dealer visit for a part replacement, software update, or inspection.

4826–4850 of 15402

  • HighNHTSA·22V088000·2022-02-16

    2022 Lincoln Aviator Fuel Filler Tube May Detach During Crash

    Ford is recalling certain 2022 Lincoln Aviator vehicles because the fuel filler tube may detach during a crash, creating a fuel leak and fire risk. Free repairs are available from Ford dealers.

    Product
    FORD — FORD, LINCOLN EXPLORER, AVIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V081000·2022-02-16

    Lamborghini Recalls Huracan Models Due to Missing Headlight Adjustment Caps

    Lamborghini is recalling 2015-2020 Huracan vehicles because missing caps on headlight adjustment screws can lead to improper alignment, reducing visibility and increasing crash risk.

    Product
    LAMBORGHINI — LAMBORGHINI HURACAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V080000·2022-02-15

    Land Rover Recalls 2020 Range Rover Evoque for SRS Warning Light Software Defect

    Jaguar Land Rover is recalling 2020 Range Rover Evoque vehicles because incorrect software may cause the airbag warning light to malfunction, potentially masking actual system failures.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER EVOQUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22E007000·2022-02-14

    Weldon recalls rear combination lamps with incorrect white backup lights

    Weldon is recalling specific rear combination lamps because the LED backup lights are the wrong color, failing federal safety standards and potentially affecting vehicle visibility.

    Product
    EXTERIOR LIGHTING:BACK UP LIGHTS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V077000·2022-02-11

    Chrysler Recalls 2017-2018 Pacifica Plug-In Hybrids for Fire Risk

    Chrysler is recalling 2017-2018 Pacifica Plug-In Hybrid vehicles because a fire can occur while parked. Owners should park outside and avoid recharging until repairs are completed.

    Product
    CHRYSLER — CHRYSLER PACIFICA PLUG-IN HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V078000·2022-02-11

    Mercedes-Benz Recalls 2021 GLB 250 Vehicles for Front Air Bag Defect

    Mercedes-Benz is recalling 2021 GLB 250 vehicles because an incorrect front driver's air bag module may not restrain occupants or could detach during a crash.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLB 250
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V076000·2022-02-10

    2022 Thor Motor Coach Motorhomes Rear Ladder Installation Defect Recall

    Thor Motor Coach is recalling 2022 ACE, Freedom Traveler, Hurricane, and Windsport motorhomes. The rear ladder may have been installed on the wrong side, which could break while in use and cause injury.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH ACE, FREEDOM TRAVELER, HURRICANE, WINDSPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V073000·2022-02-09

    Mercedes-Benz Recalls 2021 Sprinter Vans for Incorrect Weight Labeling

    Daimler Vans USA is recalling 2021 Mercedes-Benz Sprinter vans because the gross vehicle weight rating may be incorrectly stated on the tire and loading label.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SPRINTER 1500, SPRINTER 3500, SPRINTER 2500, SPRINTER 4500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V070000·2022-02-09

    2022 BMW X4 and Related Models Transmission Rollaway Risk Recall

    BMW is recalling certain 2022 330i, 530i, X3, and X4 vehicles because the transmission mechatronics unit may not have been properly assembled, potentially causing an internal leak that could lead to vehicle rollaway and crash risk.

    Product
    BMW — BMW X4, X3, 330I, 530I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V074000·2022-02-09

    Maintainer Recalls 2021-2022 Truck-Mounted Cranes Due to Fire Risk

    Maintainer is recalling 2021-2022 truck-mounted cranes because an incorrectly installed guard may damage fuel hoses or cables, increasing fire risk.

    Product
    MAINTAINER — MAINTAINER CRANE W/ SERVICE BODY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V072000·2022-02-09

    Altec Recalls 2019-2021 Aerial Devices Due to Bolt Failure Risk

    Altec is recalling 2019-2021 ATTXX-M/P/S aerial devices because over-tightened bolts in the rotation bearing may break, risking separation of the pedestal and turntable.

    Product
    ALTEC — ALTEC AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V068000·2022-02-08

    Tiffin motorhomes have improperly secured buss bars increasing fire risk

    Tiffin is recalling 2018-2022 Allegro and Allegro Breeze motorhomes where an improperly secured electrical buss bar can cause the DC Distribution Panel to overheat and potentially start fires. Dealers will replace the buss bar with a cable for free.

    Product
    TIFFIN — TIFFIN ALLEGRO, ALLEGRO BREEZE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V067000·2022-02-08

    Holiday House Travel Trailers Propane Regulator Failure Risk

    Holiday House is recalling certain 2019–2021 travel trailers equipped with defective Winntec propane regulators that may fail and increase propane pressure, raising fire risk in gas appliances.

    Product
    HOLIDAY HOUSE — HOLIDAY HOUSE 24TB, 27RQ, 18RB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V065000·2022-02-07

    Roadtrek Recreational Vehicles Recalled for Unattached Propane Lines

    Roadtrek is recalling certain 2021-2022 recreational vehicles because the propane line may not be attached to the water heater. An unattached propane line can allow gas to enter the vehicle, increasing the risk of a fire.

    Product
    ROADTREK — ROADTREK ZION SRT, ZION SLUMBER, ZION, PLAY SLUMBER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V064000·2022-02-07

    Audi Recalls 2022 Q3 Vehicles for Rearview Camera Software Error

    Audi is recalling 2022 Q3 vehicles because a software error may prevent the rearview camera from displaying an image when reversing, increasing crash risk.

    Product
    AUDI — AUDI Q3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V063000·2022-02-04

    Tesla Model Y Boombox Feature May Obscure Pedestrian Warning System

    Tesla is recalling certain 2020-2022 Model Y vehicles because the Boombox feature can obscure the Pedestrian Warning System sounds, creating a collision risk. Tesla will disable the Boombox in Drive, Neutral, and Reverse modes via software update.

    Product
    TESLA — TESLA MODEL 3, MODEL X, MODEL Y, MODEL S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V056000·2022-02-03

    Hyundai Recalls Vehicles Due to ABS Module Fire Risk

    Hyundai is recalling specific 2014-2019 models because a faulty ABS module could cause an electrical short and engine compartment fire.

    Product
    HYUNDAI — HYUNDAI TUCSON, SANTA FE, SANTA FE SPORT, SANTA FE XL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V061000·2022-02-03

    Honda Recalls 2021 CBR1000RR-R Fireblade SP Motorcycles for Fire Risk

    Honda is recalling 2021 CBR1000RR-R Fireblade SP motorcycles because an overheating exhaust pipe could melt the oil cooler pipe, causing a leak that increases the risk of fire or crash.

    Product
    HONDA — HONDA CBR1000RR
    Category
    Vehicle
    Distribution
    Distributed nationwide