1–21 of 21

  • Severity pendingNHTSA·21V617000·2021-09-27

    Toyota Recalls 2019-2020 Yaris Models for Fuel Pump Defect

    Toyota is recalling 2019-2020 Yaris vehicles because a fuel pump impeller may crack, potentially causing engine stalls and increasing crash risk.

    Product
    TOYOTA — TOYOTA YARIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V741000·2019-10-17

    Toyota Recalls Vehicles Due to Airbag Inflator Explosion Risk

    Toyota is recalling approximately 928,220 vehicles because previously replaced airbag inflators may explode due to propellant degradation, posing a risk of serious injury or death.

    Product
    LEXUS — LEXUS, TOYOTA, SCION SC430, IS 250, IS 350, RAV4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V319000·2019-04-23

    Toyota Recalls 2015-2017 Yaris Vehicles for Air Bag Wire Harness Defect

    Toyota is recalling 2015-2017 Yaris vehicles because wire harnesses for side air bag sensors may crack and corrode, potentially causing air bags to fail to deploy or deploy improperly.

    Product
    TOYOTA — TOYOTA YARIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V024000·2018-01-09

    Toyota Recalls Lexus, Scion, and Toyota Vehicles for Airbag Defect

    Toyota is recalling specific 2009-2013 Lexus, Scion, Toyota, and Pontiac vehicles because the passenger airbag inflator may explode during deployment, posing a risk of serious injury or death.

    Product
    LEXUS — LEXUS, SCION, TOYOTA IS 350C, IS 350, IS 250C, IS 250
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V025000·2018-01-09

    Toyota Recalls Yaris, Vibe, and Corolla Matrix for Air Bag Defect

    Toyota is recalling 116,126 vehicles due to a defect in passenger frontal air bag inflators that may explode during deployment, posing a risk of serious injury or death.

    Product
    TOYOTA — TOYOTA, PONTIAC COROLLA MATRIX, VIBE, YARIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V006000·2017-01-09

    Toyota Recalls Vehicles for Passenger Air Bag Inflator Rupture Risk

    Toyota is recalling specific 2006-2012 models because passenger air bag inflators may rupture in a crash, potentially sending metal fragments into the cabin.

    Product
    LEXUS — LEXUS, SCION, TOYOTA ES350, XB, IS 350, IS 250
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V367000·2016-05-26

    Toyota Recalls 2015 Yaris Vehicles Due to Front Strut Bearing Defect

    Toyota is recalling 2015 Yaris vehicles because front strut mounting bearings can be damaged by high loads, potentially causing loss of vehicle stability and increasing crash risk.

    Product
    TOYOTA — TOYOTA YARIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V340000·2016-05-23

    Toyota Recalls Vehicles for Air Bag Inflator Rupture Risk

    Toyota is recalling specific 2006-2011 Scion, Toyota, Lexus, and Pontiac vehicles because the passenger air bag inflators may rupture in a crash, potentially causing serious injury or death.

    Product
    SCION — SCION, LEXUS, TOYOTA XB, IS 250, IS F, MATRIX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V689000·2015-10-22

    Toyota Recalls Vehicles Due to Power Window Switch Fire Risk

    Toyota is recalling specific 2006-2011 models because inconsistent lubricant on the power window switch may cause overheating and fire.

    Product
    TOYOTA — TOYOTA, PONTIAC, SCION COROLLA MATRIX, COROLLA, TUNDRA, SEQUOIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V098000·2015-02-19

    Toyota Recalls 2015 Yaris Vehicles for Rear Axle Bearing Bolt Issue

    Toyota is recalling 2015 Yaris vehicles because improperly tightened rear axle bearing bolts may loosen, potentially causing the wheel to lock up or damage brake components.

    Product
    TOYOTA — TOYOTA YARIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V169000·2014-04-09

    Toyota Recalls Yaris and Scion xD for Seat Rail Spring Defect

    Toyota is recalling 2006-2010 Yaris and 2008-2010 Scion xD vehicles because seat rail springs may break, potentially allowing the seat to move during a crash.

    Product
    TOYOTA — TOYOTA, SCION YARIS, XD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V168000·2014-04-09

    Toyota and Pontiac Vehicles Recalled for Driver Airbag Cable Defect

    Toyota and General Motors are recalling specific 2006-2010 vehicles because a steering cable defect may prevent the driver's airbag from deploying in a crash.

    Product
    TOYOTA — TOYOTA, PONTIAC TACOMA, YARIS, VIBE, COROLLA MATRIX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V292000·2013-07-03

    Toyota Recalls 2012 Yaris Vehicles for Power Steering Defect

    Toyota is recalling 2012 Yaris vehicles because a relay in the power steering system could short-circuit, disabling steering assistance and increasing crash risk.

    Product
    TOYOTA — TOYOTA YARIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V491000·2012-10-10

    Toyota Recalls 2007-2009 Models for Power Window Switch Fire Risk

    Toyota is recalling approximately 2.5 million vehicles from 2007-2009 because power window switches may overheat and cause a fire.

    Product
    TOYOTA — TOYOTA, SCION, PONTIAC CAMRY, XD, CAMRY HYBRID, HIGHLANDER HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V503000·2019-06-28

    Toyota Recalls 2017-2019 Models for Incorrect Load Capacity Label

    Toyota is recalling 2017-2019 Camry, Corolla, RAV4, Sienna, and Yaris iA vehicles because an incorrect load capacity label may lead to unintentional overloading.

    Product
    TOYOTA — TOYOTA RAV4, CAMRY, SIENNA, YARIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V244000·2019-03-27

    Toyota Recalls 2019 Models Due to Illegible Load Capacity Labels

    Toyota is recalling specific 2019 models because the load capacity label text may become illegible, potentially leading to vehicle overload and increased crash risk.

    Product
    TOYOTA — TOYOTA CAMRY, AVALON, PRIUS, RAV4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V295000·2017-05-02

    Toyota Recalls 2017 Models for Improper Spare Tire Pressure

    Gulf States Toyota is recalling 2017 models because spare tires were not inflated to the proper pressure, increasing crash risk.

    Product
    TOYOTA — TOYOTA SIENNA, YARIS, RAV4 HYBRID, COROLLA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V236000·2016-04-22

    Toyota and Scion vehicles recalled for incorrect load capacity labels

    NHTSA is recalling 2016 Toyota and Scion vehicles because the load carrying capacity label may be incorrect, potentially leading to vehicle overload.

    Product
    TOYOTA — TOYOTA, SCION 4RUNNER, LAND CRUISER, YARIS, IM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V036000·2010-02-03

    Toyota and Scion Vehicles Recalled for Missing Load Capacity Labels

    NHTSA is recalling 2004-2011 Toyota and Scion vehicles sold without required load carrying capacity modification labels, which may increase crash risk if overloaded.

    Product
    TOYOTA — TOYOTA, SCION CAMRY, HIGHLANDER, TC, XB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V035000·2010-02-03

    Toyota and Scion Vehicles Recalled for Missing Tire Load Labels

    Gulf States Toyota is recalling 2005-2010 Toyota and Scion vehicles sold without required tire load capacity labels.

    Product
    SCION — SCION, TOYOTA XD, CAMRY, TC, XB
    Category
    Vehicle
    Distribution
    Distributed nationwide

NHTSA crash-test safety rating

Federal 5-Star Safety Rating from crash testing. This is a separate government program from the recall(s) above — a high star rating says nothing about whether a specific recall has been fixed, and a recall says nothing about crash-test performance.

Source: NHTSA New Car Assessment Program (NCAP), a federal crash-test program — not a recall record.

Wider context for this vehicle

Beyond the official recalls above. These are third-party figures derived from NHTSA complaint data — useful signal, but not part of our verified recall record.

Federal investigations — 2 open

  • DP23005 Defect Petition · open · service brakes, hydraulic:foundation components
  • DP23004 Defect Petition · open · electrical system:12v/24v/48v battery
  • EA12006 Engineering Analysis · electrical system
  • PE12002 Preliminary Evaluation · electrical system
  • PE10008 Preliminary Evaluation · steering
  • PE09054 Preliminary Evaluation · engine and engine cooling

Complaint clusters with no matching recall

  • 2007 · brakes — 37 complaints, median 60,447 mi
  • 2007 · suspension — 23 complaints, median 131,000 mi
  • 2008 · brakes — 22 complaints, median 56,000 mi

Technical service bulletins

711 manufacturer service bulletins across 14 model years. A TSB is repair guidance to dealers, not a safety recall.

Third-party reliability score

  • 2020: 4.3/5 · 10 complaints · most complained-of: fuel-system
  • 2019: 3.9/5 · 26 complaints · most complained-of: electrical
  • 2018: 4.5/5 · 4 complaints
  • 2017: 4.0/5 · 15 complaints · most complained-of: airbags
  • 2016: 4.4/5 · 5 complaints

This is ProblemsByVin’s own published heuristic (1 worst – 5 best), not an official rating and unrelated to our severity scale.

Data on this panel comes from ProblemsByVin, derived from US NHTSA owner complaints and recalls, and licensed CC BY 4.0. It is not published by a federal agency and is not part of our verified recall record.

← Back to all Toyota models