The Recall Desk

State

Washington product recalls

73,912 recalls have nationwide distribution and so reach Washington. 8,539 additional recalls listed Washington specifically in their distribution scope.

What the numbers show

Total
8,539
Critical
865
Severe
2,407
Most recent
2026-11-11

Of the 8,539 recalls naming Washington we have scored against our rubric, 865 (10%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,407 (28%) are Severe.

These figures cover only the 8,539 recalls whose distribution notice names Washington specifically. The 73,912 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

73151–73175 of 82451

  • HighFDA (Food)·F-0681-2013·2012-11-21

    Zatarain's Beef Flavor Rice Mix Recalled for Undeclared Wheat

    McCormick & Company is recalling Zatarain's New Orleans Style Beef Flavor Rice Mix because the product contains wheat but the label does not declare it.

    Product
    Zatarain's New Orleans Style Beef Flavor Rice Mix, packaged in 6.8 oz boxes, 12 boxes per carton, Box UPC: 7142901001
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0281-2013·2012-11-21

    Terumo Sarns Modular Perfusion System 8000 Recalled for Monitor Malfunctions

    Terumo CVS is recalling Sarns Modular Perfusion System 8000 units due to reported malfunctions in arterial and cardioplegia monitors, including power issues and inaccurate pressure alarms.

    Product
    Perfusion System 8000, base 5 pump, 115V safety monitor included The Sarns" Modular Perfusion System 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures, when…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0278-2013·2012-11-21

    Terumo HX2 Temperature Management System Recalled for Board Defects

    Terumo is recalling 19 HX2 Temperature Management Systems because AC Control boards were manufactured with incorrect flux, which may cause premature failure.

    Product
    HX2 Temp Manage SYS 120V The Terumo HX2 Temperature Management System is a selfcontained, dual channel system for supplying temperature controlled water to heat exchangers used in an extracorporeal circuit.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0283-2013·2012-11-21

    Terumo Sarns Modular Perfusion System 8000 Recalled for Monitor Malfunctions

    Terumo CVS is recalling 312 Sarns Modular Perfusion System 8000 units due to reported malfunctions in arterial and cardioplegia monitors, including power issues and inaccurate pressure alarms.

    Product
    Perfusion System 8000, base 5 pump, 220V/240V safety monitor included The Sarns" Modular Perfusion System 8000 is indicated for use for up to 6 hours on the extracorporeal circulation of blood for arterial perfusion, regional perfusion, and cardiopulmonary bypass procedures…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0682-2013·2012-11-21

    Zatarain's Chicken Flavor Rice Mix Recalled for Undeclared Wheat

    McCormick & Company is recalling Zatarain's New Orleans Style Chicken Flavor Rice Mix because the product contains wheat but the label does not declare it.

    Product
    Zatarain's New Orleans Style Chicken Flavor Rice Mix, Item No. Z09705, packaged in 6.3 oz boxes, 12 boxes per carton, Box UPC: 7142901001
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0276-2013·2012-11-21

    Progressive Medical Recalls Endoscopic Dissectors with Broken Sterile Seals

    Progressive Medical Inc. is recalling 70 boxes of PMI Endoscopic Dissectors because some sterile packages had broken seals, potentially compromising sterility.

    Product
    Progressive Medical PMI Endoscopic Dissector with Kittner Tip (5mm x 40cm), Reorder Number: PMILK40, Product Sterile in Unopened/Undamaged pouch, Cotton Tip - X-Ray Detectable, 1 Pc/Pouch, 10 Pouches/Box, 20 boxes/case. Exclusively Distributed in the U.S. Market by: Progressive…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0277-2013·2012-11-21

    Synthes External Fixation Clamp Recalled for Incorrect MR Safety Labeling

    Synthes USA HQ, Inc. is recalling 8 units of External Fixation System Tube to Tube Clamps because the provided insert incorrectly states the product is MR safe, while the device is actually MR Conditional.

    Product
    Synthes External Fixation System Tube to Tube Clamp, Part Number 390.007. Intended for use to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: Stabilization of soft tissues and fractures…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-055-2013·2012-11-21

    Ameridose Recalls Non-Sterile Drug Products Due to GMP Deficiencies

    Ameridose LLC is voluntarily recalling all non-sterile products nationwide due to Good Manufacturing Practice (GMP) deficiencies. The recall was initiated in October 2012.

    Product
    All Non-Sterile Products manufactured by Ameridose LLC, Westborough, MA. A complete list of all products subject to this recall can be accessed on-line at www.ameridose.com
    Category
    Drug
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0295-2013·2012-11-21

    Gulf South Medical Supply Recalls Vinyl Exam Gloves Shipped Before Customs Clearance

    Gulf South Medical Supply is recalling Select Medical Products Vinyl Powder-Free Exam Gloves because they were shipped before U.S. Customs cleared them for sale.

    Product
    Select Medical Products Vinyl Powder-Free Exam Gloves, Medium Model # 6370 and Large Model # 6371, 100 per box; 10 boxes per case. Usage: Patient Examination.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-056-2013·2012-11-21

    ITW Dymon Recalls Lemon Hand Sanitizing Wipes for CGMP Deviations

    ITW Dymon is recalling specific lots of Lemon Hand Sanitizing Wipes because they were manufactured with raw material containing unknown particles believed to be water and dirt.

    Product
    Lemon Hand Sanitizing Wipes [n-alkyl dimethyl benzyl ammonium chloride (0.1%) and n-alkyl dimethyl ethyl benzyl ammonium chloride (0.1%)], labeled as a) Genuine Joe Cleaning Supplies, Lemon Scent, Anti-microbial Hand Sanitizing Wipes, 120-count premoistened wipes per bucket, 6…
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0289-2013·2012-11-21

    Horiba Medical Recalls ABX PENTRA Creatinine 120 CP Reagent

    Horiba Medical is recalling ABX PENTRA Creatinine 120 CP reagent because a calibration alarm prevents the assay from being used.

    Product
    ABX PENTRA Creatinine 120 CP, Model Number Creatinine Part # A11A01868, Lot Numbers: 203273706, 203273707, 203273808, 203273709. The ABX PENTRA Creatinine 120 CP is an in vitro diagnostic assay for the quantitative determination of creatinine in human serum, plasma and urine…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V541000·2012-11-20

    Starcraft Recalls 2013 Autumn Ridge AR-One Travel Trailers for Wiring Defect

    Starcraft is recalling 22 model year 2013 Autumn Ridge AR-One travel trailers because loose electrical wiring connections could cause excessive heat, leading to fire, injury, or death.

    Product
    STARCRAFT — STARCRAFT AUTUMN RIDGE AR-ONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·13706·2012-11-15

    John Deere Recalls Utility Vehicles Due to Fuel Filter Fire Hazard

    John Deere is recalling about 4,340 Gator utility vehicles with Kawasaki engines because the fuel filter can leak, posing a fire hazard. No injuries have been reported.

    Product
    Utility Vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·13041·2012-11-15

    Kawasaki Recalls Lawn Mower Fuel Filters Due to Fire Hazard

    Kawasaki Motors is recalling fuel filters and tune-up kits for lawn mowers and utility vehicles because the filters can leak fuel, posing a fire hazard.

    Product
    Fuel Filters and Tune-Up Kits with Fuel Filters
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V540000·2012-11-15

    Volkswagen Recalls 2012-2013 Beetles for Airbag Sensor Defect

    Volkswagen is recalling 2012-2013 Beetles with leather sport seats because a wet seat may prevent the airbag from turning off, increasing injury risk for children.

    Product
    VOLKSWAGEN — VOLKSWAGEN BEETLE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V539000·2012-11-15

    Volvo Bus 9700 Recalled for Wheelchair Lift Safety Pin Defects

    Prevost is recalling 44 Volvo Bus 9700 coaches because missing or inoperable wheelchair lift safety pins may prevent safe stowing, increasing injury risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·13040·2012-11-15

    Kawasaki Recalls Lawn Mower Engines Due to Fuel Leak Fire Hazard

    Kawasaki Motors is recalling about 210,000 lawn mower engines because the fuel filter can leak, posing a fire hazard. No injuries have been reported.

    Product
    Lawn Mower Engines
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V538000·2012-11-15

    Blue Bird Recalls 2013-2014 Vision School Buses Due to Brake Light Defect

    Blue Bird is recalling 452 model year 2013 and 2014 Vision school buses equipped with Ford 6.8L propane engines because the brake light switch may malfunction, increasing crash risk.

    Product
    BLUE BIRD — BLUE BIRD VISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-0599-2013·2012-11-14

    Fresh Express Hearts of Romaine Recalled Due to Salmonella Contamination

    Fresh Express is recalling 18 oz Hearts of Romaine packages because samples tested positive for Salmonella. The product was distributed in 11 states and Canada.

    Product
    Fresh Express, Hearts of Romaine, 18 oz, Fresh Express Incorporated, packed in clear flexible plastic package.
    Category
    Food
    Distribution
    10 states