  • ModerateFDA (Devices)·Z-0024-2025·2024-10-16

    iCast Covered Stent Recalled for Unique Device Identifier Labeling Error

    Atrium Medical Corporation is recalling 11 iCast Covered Stents (Model 42616) due to an error in the Unique Device Identifier (UDI) printed on the distribution label. No illnesses or injuries have been reported.

    Product
    iCast Covered Stent, 6MMx16MMx120CM, Model Number 42616
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0029-2025·2024-10-16

    Aligned Medical Septo Pack recalled for containing component under FDA recall

    The Aligned Medical Septo Pack (AMS11480) is recalled because it contains a Cardinal Health Salem Sump PVC tube component that is subject to an FDA recall for improper use.

    Product
    Aligned Medical Septo Pack REF AMS11480 that contains the Cardinal Health Salem Sump PVC tubes. Product packaged in a convenient manner for use in a general clinical procedure.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0028-2025·2024-10-16

    Aligned Medical Tonsil ENT Pack Recalled for Component Under Separate Recall

    Windstone Medical is recalling 894 Aligned Medical Tonsil ENT Packs containing Cardinal Health Salem Sump PVC tubes due to improper use concerns with a component under a separate recall action.

    Product
    Aligned Medical Tonsil ENT Pack REF AMS9977 that contains the Cardinal Health Salem Sump PVC tubes. Product packaged in a convenient manner for use in a general clinical procedure.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0044-2025·2024-10-16

    MAKO Integrated Cutting System Handpiece Recalled for Characterization Process Error

    Howmedica Osteonics Corp. is recalling 897 MAKO Integrated Cutting System (MICS) Handpieces worldwide due to a manufacturing characterization process error that resulted in incorrect constant values being assigned to affected units.

    Product
    MAKO Integrated Cutting System (MICS) HANDPIECE, Catalog Number 209063
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0031-2025·2024-10-16

    Aligned Medical Tonsil Packs Recalled Due to Improper-Use Kit Component

    Windstone Medical Packaging is recalling Aligned Medical Tonsil Pack kits due to a component under recall for improper use. Approximately 180 packs were distributed nationwide.

    Product
    Aligned Medical Tonsil Pack REF AMS14809 that contains the Cardinal Health Salem Sump PVC tubes. Product packaged in a convenient manner for use in a general clinical procedure.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0041-2025·2024-10-16

    Inspire Model 4063 Stimulation Lead Labeling Error — Serial Number Mismatch

    Inspire Medical Systems is recalling 457 Model 4063 Stimulation Leads because the serial number on the shelf box does not match the serial number of the device inside, creating identification and traceability issues.

    Product
    Inspire Model 4063 Stimulation Lead, component of the Inspire Upper Airway Stimulation (UAS) system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0030-2025·2024-10-16

    Aligned Medical T and A Pack Recalled for Component Misuse Risk

    Windstone Medical Packaging is recalling Aligned Medical T and A Pack REF AMS11482 because it contains a component subject to a separate recall action for improper use.

    Product
    Aligned Medical T and A Pack REF AMS11482 that contains the Cardinal Health Salem Sump PVC tubes. Product packaged in a convenient manner for use in a general clinical procedure.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V765000·2024-10-15

    Lamborghini Recalls 2024 Revuelto Vehicles Due to Wiper Rod Defect

    Lamborghini is recalling 2024 Revuelto vehicles because a wiper connecting rod may bend and separate, causing wiper failure and reduced visibility.

    Product
    LAMBORGHINI — LAMBORGHINI REVUELTO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V764000·2024-10-15

    2018–2022 BMW X3 rear cargo rail attachment defect recall

    BMW is recalling 2018–2022 X3 vehicles because rear cargo rail attachment bolts may become damaged in a rear crash, causing the rail to detach and increasing injury risk. Dealers will replace the bolts free of charge.

    Product
    BMW — BMW X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V767000·2024-10-15

    2024 Toyota Sequoia Hybrid and Tundra Tire Sidewall Damage Recall

    Certain 2024 Toyota Sequoia Hybrid, Tundra, and Tundra Hybrid vehicles are recalled due to passenger-side front and rear tire sidewall damage that may cause sudden tire pressure loss and loss of vehicle control.

    Product
    TOYOTA — TOYOTA TUNDRA, TUNDRA HYBRID, SEQUOIA HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·24V766000·2024-10-15

    McNeilus Recalls Rear Loaders Due to License Plate Light Defect

    McNeilus is recalling 2010-2024 Rear Loader vehicles because the license plate light is installed in the wrong location, potentially failing to fully illuminate the plate.

    Product
    MCNEILUS — MCNEILUS REAR LOADER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V762000·2024-10-14

    Entegra Ethos and Jayco Swift Incorrect Tire Load Label Recall

    Jayco is recalling 2,044 units of 2021–2025 Entegra Ethos and Jayco Swift vehicles due to an incorrect Tire and Loading Information Label. The mislabeled tire load range could lead owners to select underrated replacement tires, increasing crash risk.

    Product
    JAYCO — JAYCO, ENTEGRA SWIFT LI, SWIFT, ETHOS LI, ETHOS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V763000·2024-10-14

    2025 Honda Civic fuel pump defect poses fire risk

    Honda is recalling certain 2023-2025 model year Civic vehicles because the high-pressure fuel pump may crack and leak fuel, increasing the risk of fire if an ignition source is present. Owners should contact Honda for free inspection and replacement.

    Product
    HONDA — HONDA ACCORD, CIVIC, CIVIC HYBRID, CR-V HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V759000·2024-10-11

    Blue Bird Transit Bus Recall for Illegible Emergency Exit Labels

    Blue Bird is recalling 2020-2024 All American and 2021-2024 Vision transit buses because emergency exit labels are too small to read, potentially delaying evacuation.

    Product
    BLUE BIRD — BLUE BIRD ALL AMERICAN TRANSIT BUS, VISION TRANSIT BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V760000·2024-10-11

    E-One Recalls Fire Trucks Due to Engine Crossmember Defect

    E-One is recalling 282 fire trucks because a broken engine crossmember can damage the cooling fan, causing an engine stall and increasing crash risk.

    Product
    E-ONE — E-ONE TYPHOON N, CYCLONE N, QUEST II, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V758000·2024-10-11

    Blue Bird Recalls School Buses for Illegible Emergency Exit Labels

    Blue Bird is recalling 2019-2024 Vision and All American school buses because emergency exit labels are too small to read, potentially delaying evacuation.

    Product
    BLUE BIRD — BLUE BIRD ALL AMERICAN, VISION, VISION SCHOOL BUS, ALL AMERICAN SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V761000·2024-10-11

    Hyundai Nexo Hydrogen Pressure Relief Device Defect Creates Fire Risk

    Hyundai is recalling 2019-2024 Nexo vehicles because the hydrogen pressure relief device may fail and leak, creating a fire risk. Owners are advised to park outside until the repair is complete.

    Product
    HYUNDAI — HYUNDAI NEXO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalCPSC·25009·2024-10-10

    Fisher-Price Recalls 2.1 Million Snuga Infant Swings for Suffocation Risk

    Fisher-Price is recalling approximately 2.1 million Snuga Infant Swings due to suffocation hazard when the product is used for sleep or bedding is added. Five deaths have been reported between 2012 and 2022.

    Product
    All Models of Fisher-Price Snuga Swings
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E084000·2024-10-10

    Jaguar Recalls AJ20-P6 Engines Due to Oil Filter Housing Leak Risk

    Jaguar is recalling certain AJ20-P6 replacement engines because the oil filter housing may crack and leak, posing a fire and crash risk.

    Product
    ENGINE AND ENGINE COOLING:ENGINE:OIL/LUBRICATION recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E085000·2024-10-10

    Land Rover Recalls AJ20-P6 Engines for Oil Filter Housing Cracks

    Land Rover is recalling AJ20-P6 replacement engines because the oil filter housing may crack and leak, increasing the risk of fire or road hazards.

    Product
    ENGINE AND ENGINE COOLING:ENGINE:OIL/LUBRICATION recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V756000·2024-10-10

    GM Recalls 2018-2019 Trucks for Air Bag Inflator Defect

    General Motors is recalling specific 2018-2019 Chevrolet and GMC trucks because side air bag inflators may rupture, posing an injury risk.

    Product
    GMC — GMC, CHEVROLET SIERRA 3500, SIERRA 2500, SILVERADO 3500, SILVERADO 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V754000·2024-10-10

    2020-2023 RAM 1500 Heated Rearview Mirror Glass May Detach

    Chrysler is recalling 2020-2023 RAM 1500 vehicles with heated trailer tow rearview mirrors. The mirror glass may detach, reducing driver visibility and increasing crash risk.

    Product
    RAM — RAM 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V755000·2024-10-10

    2024 GMC Sierra EV front turn signals may be difficult to see

    General Motors is recalling certain 2024 GMC Sierra EV vehicles. The front turn signal lights are too similar in brightness to the parking lights, making them difficult to see and increasing crash risk.

    Product
    GMC — GMC SIERRA EV
    Category
    Vehicle
    Distribution
    Distributed nationwide