  • HighNHTSA·26E055000·2026-08-12

    Mack Recalls Grote Replacement Marker Lights for Visibility Failure

    Mack Trucks is recalling certain Grote replacement marker lights that may fail to illuminate, reducing vehicle visibility and increasing crash risk.

    Product
    GROTE — GROTE CLEARANCE/MARKER LAMP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2858-2026·2026-08-12

    Medical Action Industries Recalls Dialysis Change Tray Kits Due to Seal Defect

    Medical Action Industries is recalling 3,740 Dialysis Change Tray Clear Sequence kits because the needle-free access device may have an improper seal.

    Product
    Brand Name: Medical Action Industries Product Name: Dialysis Change Tray Clear Sequence Model/Catalog Number: 78791
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2874-2026·2026-08-12

    Merge PACS Medical Imaging Workstation Recalled Due to Patient Data Display Error

    Merge Healthcare is recalling 53 Merge PACS medical imaging workstations due to a software issue where thumbnails from one patient's study may incorrectly display when viewing a different patient's study, potentially compromising patient confidentiality.

    Product
    Merge PACS, medical imaging diagnostic workstation
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2836-2026·2026-08-12

    FORWARD Oral Airway Kit Recall for Potential Airway Obstruction

    Integrated Medcraft LLC recalls FORWARD Oral Airway Kits due to potential occlusion of the airway tip, which could impede breathing in medical settings.

    Product
    FORWARD Oral Airway Kit (OPA Sizes 5, 6.5, 7, 8, 9, 10, 12). REF Number: 1011-40002. Containing the affected One-piece Guedel airway components: 1. Size 00, ISO 5.0, blue. Product Code: 1100050. 2. Size 000, ISO 3.5, light green. Product Code: 1000035.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2902-2026·2026-08-12

    Peripheral Nerve Repair Device Relabeled Due to Unsubstantiated Shelf Life

    Tissium SA is relabeling COAPTIUM CONNECT nerve repair devices because the 36-month shelf life is not supported by real-time data. The revised shelf life is 26 months.

    Product
    Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO1575 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2899-2026·2026-08-12

    GEM Premier 7000 with iQM3 Blood Analysis Systems Recalled for Solution Concentration Issues

    Instrumentation Laboratory is recalling specific GEM Premier 7000 with iQM3 PAK lots because the lysing bag solution concentration does not meet manufacturing specifications, potentially delaying medical management.

    Product
    GEM Premier 7000 with iQM3 Part Numbers: 00077407508 00077407510 00077415004 00077415008 00077415010 00077430010 Product Description: The GEM Premier 7000 with iQM3 is a portable critical care system for use by health care professionals to rapidly analyze lithium…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2901-2026·2026-08-12

    COAPTIUM Connect Nerve Repair Device Relabeled Due to Unsubstantiated Shelf Life

    Tissium SA is relabeling COAPTIUM Connect nerve repair devices to reduce the shelf life from 36 to 26 months because the original duration was not supported by real-time data.

    Product
    Brand Name: COAPTIUM Connect Product Name: COAPTIUM Connect Model/Catalog Number: NCOCO1510 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2885-2026·2026-08-12

    U2 Total Knee System Femoral Valgus Adaptor Recall

    United Orthopedic Corp. is recalling its U2 Total Knee System femoral valgus adaptors due to a manufacturing defect that prevents proper assembly of the stem component during surgery.

    Product
    Brand Name: U2 Total Knee System Product Name: Femoral valgus adaptor, left and right Model/Catalog Number: 9323-5333 and 9323-5334 Software Version: N/A Product Description: Manual Orthopedic Surgical Instrument Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2844-2026·2026-08-12

    Quantum Rehab R-TRAK Powered Wheelchair Controller Recalled Due to Software Issue

    Pride Mobility Products Corp. is recalling Quantum Rehab R-TRAK powered wheelchairs due to a software issue that can cause unexpected braking or system crashes.

    Product
    Brand Name: Quantum Rehab Product Name: R-TRAK Model/Catalog Number: R-TRAK Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2893-2026·2026-08-12

    Philips Fluoroscopy System Recall Over Hard Disk Drive Issue

    Philips is recalling 257 Allura/Centron interventional fluoroscopic X-ray systems due to potential loss of imaging, motorized movement, or data caused by unauthorized hard disk drives.

    Product
    Philips Allura, Cardio Vascular-Allura Centron. Model Number: 722400. Interventional Fluoroscopic X-Ray System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2848-2026·2026-08-12

    Quantum Rehab Q6 Edge 2.0 Wheelchair Recall Due to Safety Risks

    The FDA is recalling the Quantum Rehab Q6 Edge 2.0 powered wheelchair because its controller may cause unexpected braking or system crashes that could lead to falls and injuries.

    Product
    Brand Name: Quantum Rehab Product Name: Q6 Edge 2.0 (ilevel) Model/Catalog Number: Q6 Edge 2.0 (ilevel) Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2894-2026·2026-08-12

    5-PLASMA Bivalirudin AMR Verification Kit Recalled Due to Stability Issues

    Aniara Diagnostica LLC recalls its 5-PLASMA Bivalirudin AMR Verification Kit due to stability issues causing degradation of measurable bivalirudin in controls, calibrators, and linearity values. FDA Class II recall.

    Product
    5-PLASMA Bivalirudin AMR Verification Kit, Model Number 5D-45905
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2903-2026·2026-08-12

    Tissium Peripheral Nerve Repair Device Shelf Life Recall

    Tissium SA is recalling the COAPTIUM CONNECT peripheral nerve repair device due to an unsubstantiated 36-month shelf life; devices will be relabeled to a validated 26-month shelf life.

    Product
    Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO2010 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2865-2026·2026-08-12

    Stryker Single Spike Tube Set Recalled for Leaking During Use

    Stryker is recalling 11,857 Single Spike Tube Sets due to reports of leaking from the handpiece during use.

    Product
    STRYKER PKG., SINGLE SPIKE TUBE SET, Catalog Number 0250070530
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2863-2026·2026-08-12

    Stryker Ahto Tube Set Recalled for Handpiece Leaking During Use

    Stryker is recalling 41,052 Ahto Tube Sets worldwide due to reports of handpiece leaking during use.

    Product
    STRYKER AHTO TUBE SET WITH TIP PACKAGING, Catalog Number 0250070620
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2877-2026·2026-08-12

    FilmArray NGDS Warrior Panel Diagnostic Test Recalled Due to Strain Mismatch

    Biofire Defense is recalling FilmArray NGDS Warrior Panel kits because the test may not correctly identify certain outbreak strains due to mismatches with the reference strain used during development.

    Product
    FilmArray NGDS Warrior Panel REF NGDS-ASY-0007 UDI-DI code: (01)00851458005136 The FilmArray NGDS Warrior Panel is a qualitative, multiplexed, nucleic acid-based in vitro diagnostic test intended for use with the FilmArray 2.0 system. The FilmArray NGDS Warrior Panel detects…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2907-2026·2026-08-12

    Coaptium Connect Nerve Repair Device Relabeled Due to Unsubstantiated Shelf Life

    Tissium SA is relabeling Coaptium Connect nerve repair devices because the current 36-month shelf life is not supported by real-time data. The shelf life is being reduced to 26 months.

    Product
    Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO5010 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2839-2026·2026-08-12

    Biopsy Forceps Recall: Sterile Packaging Breach Risk

    Boston Scientific is recalling Radial Jaw 4 Large Capacity Biopsy Forceps due to a potential breach in the sterile barrier of device packaging, which could compromise sterility.

    Product
    Radial Jaw 4 Large Capacity Biopsy Forceps with the following descriptions and UPN: 1. Radial Jaw 4 LC 240cm Box 20; Outer Box UPN: M00513321; Inner Box UPN: M00513320. 2. Radial Jaw 4 LC 240cm Box 40; Outer Box UPN: M00513322; Inner Box UPN: M00513320. 3. Radial…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2861-2026·2026-08-12

    DASH Rapid PCR Instrument Recalled Due to Software Issue Causing False Co-infection Results

    Nuclein LLC is recalling the DASH Rapid PCR Instrument (Model SG-0002) because a software issue may result in false co-infection readings.

    Product
    Brand Name: DASH Rapid PCR Instrument Product Name: DASH Rapid PCR Instrument Model/Catalog Number: SG-0002 Software Version: 6.0.2 Product Description: The DASH¿ Rapid PCR Instrument (DASH Instrument) is an automated, fluorescence-based, reverse-transcription polymerase…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2849-2026·2026-08-12

    Quantum Rehab Q6 Edge 3 Powered Wheelchair Controller Recalled for Unexpected Braking

    Pride Mobility Products Corp. is recalling the Quantum Rehab Q6 Edge 3 powered wheelchair controller due to a software issue that can cause unexpected braking and potential injury.

    Product
    Brand Name: Quantum Rehab Product Name: Q6 Edge 3 Model/Catalog Number: Q6 Edge 3 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2847-2026·2026-08-12

    Powered Wheelchair Controller Software May Cause Unexpected Brake Stop

    Pride Mobility is recalling 1,102 Quantum 1450 powered wheelchairs with controller software version 2.0.11 because reminder pop-ups can trigger an unexpected park brake stop while driving, risking falls or injury.

    Product
    Brand Name: Quantum Rehab Product Name: Quantum 1450 Model/Catalog Number: Quantum 1450 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2886-2026·2026-08-12

    United Orthopedic Corp. Recalls Femoral Valgus Offset Adaptors for U2 Total Knee System

    United Orthopedic Corp. is recalling specific femoral valgus offset adaptors used in the U2 Total Knee System due to a manufacturing defect in a component screw.

    Product
    Brand Name: U2 Total Knee System Product Name: Femoral valgus offset adaptor, 2mm, 4mm, 6mm, left and Femoral valgus offset adaptor, 2mm, 4mm, 6mm, right Model/Catalog Number: 9323-5335, 9323-5337, 9323-5339 and 9323-5336, 9323-5338, 9323-5340 Software Version: N/A Product…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2846-2026·2026-08-12

    Quantum Rehab Q6 Edge 2.0 Power Wheelchair Recall

    Pride Mobility is recalling 1,102 Q6 Edge 2.0 power wheelchairs due to a software issue that may cause unexpected braking or control system crashes during use.

    Product
    Brand Name: Quantum rehab Product Name: Q6 Edge 2.0 Model/Catalog Number: Q6 Edge 2.0 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2906-2026·2026-08-12

    COAPTIUM CONNECT Peripheral Nerve Repair Device Recall for Shelf Life Labeling

    TISSIUM SA recalls COAPTIUM CONNECT nerve repair devices due to unvalidated 36-month shelf life labeling. Revised 26-month label will be applied. Device breakage beyond validated shelf life may require revision surgery.

    Product
    Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO4010 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide