The Recall Desk

State

New Hampshire product recalls

72,919 recalls have nationwide distribution and so reach New Hampshire. 4,444 additional recalls listed New Hampshire specifically in their distribution scope.

What the numbers show

Total
4,444
Critical
596
Severe
846
Most recent
2026-09-09

Of the 4,444 recalls naming New Hampshire we have scored against our rubric, 596 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 846 (19%) are Severe.

These figures cover only the 4,444 recalls whose distribution notice names New Hampshire specifically. The 72,919 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

2576–2600 of 77363

  • HighFDA (Devices)·Z-1747-2026·2026-04-08

    MiniMed 620G insulin pump delivery varies with pump height changes

    Medtronic is recalling MiniMed 620G insulin pumps because raising or lowering the pump relative to the infusion site can cause unintended over- or under-delivery of insulin.

    Product
    MiniMed 620G Insulin Pump (MMT-1750)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1764-2026·2026-04-08

    Burlington Medical blockers may lose radiation attenuation over time

    Burlington Medical is recalling blockers because of the potential for attenuation degradation over time, decreasing the lifespan of the product.

    Product
    Burlington Medical, Blockers.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1695-2026·2026-04-08

    Olympus SOLTIVE Pro laser power supply may fail producing smoke

    Olympus is recalling SOLTIVE Pro SuperPulsed Laser Systems because a potential defect in the 24V power supply module may render the system inoperable and produce smoke or a burning smell.

    Product
    Brand Name: Olympus SOLTIVE Pro SuperPulsed Laser System Product Name: SOLTIVE Pro Laser System TFL-SLS Model/Catalog Number: TFL-SLS containing TFL-CSLU Product Description: An electricity powered device assembly which emits a high-power laser beam to vaporize/ablate soft tis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1672-2026·2026-04-08

    Philips Allura Xper FD20/15 OR Table X-ray may not start

    Philips is recalling the Allura Xper FD20/15 OR Table because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD20/15 OR Table; System Code: 722059;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1671-2026·2026-04-08

    Philips Allura Xper FD20/15 X-ray may not start from foot switch

    Philips is recalling the Allura Xper FD20/15 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD20/15; System Code: 722058;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1709-2026·2026-04-08

    Medline laryngoscopy bronchoscopy kits contain Olympus valves shedding rubber fragments

    Medline is recalling four bronchoscopy and laryngoscopy kits because they contain recalled Olympus biopsy valves, where rubber fragments may detach from the valve slit during use.

    Product
    Medline kits containing Olympus biopsy valves: 1. BRONCHOSCOPY, DYNJ900898I DYNJ901922G 2. FLEXIBLE BRONCHOSCOPY KIT, DYKM1417I DYKM1417J 3. LARYNGOSCOPY/BRONCHOSCOPY PACK, DYNJ58146A 4. RIGID KIT, DYNDA2138A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1760-2026·2026-04-08

    Burlington Medical caps may lose radiation attenuation over time

    Burlington Medical is recalling protective caps made with Xenolite 800 attenuation material because of the potential for attenuation degradation over time.

    Product
    Burlington Medical, Caps.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1680-2026·2026-04-08

    Philips Azurion 5 M20 X-ray may not start from foot switch

    Philips is recalling the Azurion 5 M20 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Azurion 5 M20; System Code: (1)722228, (2)722232, (3) 722281 (OUS only);
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateNHTSA·26V221000·2026-04-08

    Forest River Recalls 2026 Travel Trailers Due to Incorrect Weight Labeling

    Forest River is recalling 2026 Westbrook and Avenger travel trailers because the Federal Placard label may list an incorrect dry weight, potentially leading to vehicle overloading.

    Product
    FOREST RIVER — FOREST RIVER AVENGER, WESTBROOK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V219000·2026-04-06

    Greenpower Recalls School Buses Due to Missing Mirror Warning Label

    Greenpower is recalling 2020-2024 Nano Beast and 2021-2024 Beast school buses because a warning label on the cross-view mirror may be missing, potentially increasing crash risk.

    Product
    GREENPOWER — GREENPOWER NANO BEAST SCHOOL BUS, BEAST SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V217000·2026-04-06

    Pierce Recalls Firetrucks Due to Faulty Stabilizer Indicator Light

    Pierce Manufacturing is recalling 2015-2026 aerial firetrucks because a faulty light may falsely indicate the vehicle is stable, increasing injury risk during operation.

    Product
    PIERCE — PIERCE IMPEL, ENFORCER, ARROW XT, VELOCITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V218000·2026-04-06

    2024 Genesis G90 seat belt anchors may detach in crash

    Hyundai is recalling certain 2023–2026 Genesis G90 vehicles because driver and passenger seat belt anchors may detach. Detached anchors cannot adequately restrain occupants in a crash, increasing injury risk.

    Product
    HYUNDAI — HYUNDAI, GENESIS SANTA FE HYBRID, IONIQ 6, SANTA FE, G90
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • LowUSDA FSIS·PHA-04012026-01·2026-04-06

    USDA Retracts Lead Alert for Dorada Chicken Nuggets

    USDA FSIS retracted a public health alert for Dorada chicken nuggets after follow-up testing confirmed the initial lead result was a laboratory error.

    Product
    Dorada Foods — FSIS Retracts Public Health Alert for Frozen, Ready-to-Eat Chicken Nuggets Due to Updated Laboratory Result
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V216000·2026-04-03

    Mercedes-Benz Recalls Vehicles for Drive Shaft Universal Joint Breakage Risk

    Mercedes-Benz is recalling specific 2018-2020 E-Class and S-Class models because the drive shaft universal joint may break, causing a sudden loss of drive power and increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, MERCEDES-MAYBACH S 560 4MATIC COUPE, E 450 4MATIC, E 400 4MATIC, E 400 4MATIC CABRIOLET
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26379·2026-04-02

    HTRC and Haisito battery chargers can ignite causing fires

    Huizhou Haitan Technology is recalling T400 battery chargers because they can ignite or cause a connected battery to ignite. Thirty-three fires and explosions have been reported.

    Product
    HTRC and Haisito battery chargers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·26377·2026-04-02

    Granitestone sauté pan handle screw caps can eject when heated

    E Mishan & Sons is recalling Granitestone Diamond Pro Blue sauté pans because the metal cap on the handle screw can detach and forcefully eject when heated. One injury has been reported.

    Product
    Granitestone Diamond Pro Blue Sauté Pans
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·26382·2026-04-02

    Universal Broadmoore canopy bed beams can collapse when bed is moved

    Samson International is recalling Universal Broadmoor Bellevue and Oaklynn canopy bed frames because the canopy beams can collapse. Four consumers sustained contusion injuries.

    Product
    Universal Broadmoore brand Bellevue and Oaklynn model canopy bed frames
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·26E018000·2026-04-02

    Sleepy Customs Recalls IS300 Slave Cylinder Conversion Kits

    Sleepy Customs LLC is recalling IS300 Slave Cylinder Conversion Kits because the adapter plate may separate, causing loss of clutch function and increasing crash risk.

    Product
    POWER TRAIN:CLUTCH ASSEMBLY:SLAVE CYLINDER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V213000·2026-04-02

    Corvettes recalled over undetected rear turn signal light failures

    General Motors is recalling 32,988 Chevrolet Corvette vehicles because a software error may prevent detection of a rear turn signal light failure.

    Product
    CHEVROLET — CHEVROLET CORVETTE COUPE, CORVETTE CONVERTIBLE, CORVETTE CONVERTIBLE E-RAY, CORVETTE COUPE E-RAY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V214000·2026-04-02

    BMW motorcycles recalled over a reverse gear unit that may overheat

    BMW of North America is recalling 9,160 K 1600 motorcycles because a deteriorating seal can let moisture into the reverse gear control unit, causing it to overheat.

    Product
    BMW — BMW K 1600 GTL, K 1600 GT, K 1600 GRAND AMERICA, K 1600 B
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26378·2026-04-02

    Sangohe adult portable bed rails pose entrapment and asphyxiation hazard

    Sangohe adult portable bed rails models 504E and 504Q are being recalled because users can become entrapped within the rail or between the rail and the mattress.

    Product
    Sangohe Adult Portable Bed Rails
    Category
    Consumer Product
    Distribution
    Distributed nationwide