The Recall Desk

State

Kansas product recalls

73,741 recalls have nationwide distribution and so reach Kansas. 5,821 additional recalls listed Kansas specifically in their distribution scope.

What the numbers show

Total
5,821
Critical
1,053
Severe
1,485
Most recent
2026-10-28

Of the 5,821 recalls naming Kansas we have scored against our rubric, 1,053 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,485 (26%) are Severe.

These figures cover only the 5,821 recalls whose distribution notice names Kansas specifically. The 73,741 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

38426–38450 of 79562

  • SevereNHTSA·18V937000·2018-12-31

    Arcimoto Recalls 2017 FUV Motorcycles Due to Brake System Defect

    Arcimoto is recalling 2017 FUV motorcycles because the brake system design may fail to meet federal stopping distance requirements, increasing crash risk.

    Product
    ARCIMOTO — ARCIMOTO FUV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V940000·2018-12-31

    Arcimoto Recalls 2017 FUV Motorcycles Due to Brake Fitting Defect

    Arcimoto is recalling 2017 FUV motorcycles because incorrect fittings in the braking system may cause fluid leaks, reducing brake effectiveness and increasing crash risk.

    Product
    ARCIMOTO — ARCIMOTO FUV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V943000·2018-12-31

    Arcimoto Recalls 2017-2018 FUV Motorcycles for Headlight Spacing Defect

    Arcimoto is recalling 2017-2018 FUV motorcycles because the headlights may be spaced too far apart, making the vehicle difficult to recognize as a motorcycle in the dark.

    Product
    ARCIMOTO — ARCIMOTO FUV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V942000·2018-12-31

    Arcimoto Recalls 2017-2018 FUV Motorcycles for Missing Side Reflectors

    Arcimoto is recalling 2017-2018 FUV motorcycles because the rear light assembly lacks required side reflex reflectors, reducing visibility and increasing crash risk.

    Product
    ARCIMOTO — ARCIMOTO FUV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V941000·2018-12-31

    Arcimoto Recalls 2017-2018 FUV Motorcycles for Turn Signal Placement

    Arcimoto is recalling 2017-2018 FUV motorcycles because front turn signals are not positioned as required by federal safety standards, potentially reducing visibility.

    Product
    ARCIMOTO — ARCIMOTO FUV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V935000·2018-12-31

    Subaru Recalls 2018 Models for Rearview Camera Software Defect

    Subaru is recalling 2018 Legacy, Outback, and BRZ vehicles because a software issue may prevent the rearview camera from displaying an image while backing up.

    Product
    SUBARU — SUBARU OUTBACK, LEGACY, BRZ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·125-2018·2018-12-30

    Zeigler Red Hot Sausage Recalled for Metal Contamination

    R. L. Zeigler Co. is recalling Red Hot chicken and pork sausage products due to possible metal contamination. No illnesses have been reported.

    Product
    R. L. Zeigler Co. Inc. — R. L. Zeigler Co., Inc. Recalls Chicken and Pork Red Hot Sausage Products due to Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V934000·2018-12-28

    Hyundai Recalls Sonata and Santa Fe Sport for Fuel Pipe Fire Risk

    Hyundai is recalling 2011-2014 Sonata and 2013-2014 Santa Fe Sport vehicles because a fuel pipe may leak, increasing the risk of a fire.

    Product
    HYUNDAI — HYUNDAI SONATA, SANTA FE SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V933000·2018-12-27

    Forest River Recalls 2019 Salem and Wildwood Trailers for Fire Risk

    Forest River is recalling 2019 Salem and Wildwood recreational trailers because the power cord hatch is located above the water heater exhaust, which may cause melting and increase fire risk.

    Product
    FOREST RIVER — FOREST RIVER SALEM, WILDWOOD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-0360-2019·2018-12-26

    Lubrisine eye drops recalled for undeclared colloidal silver and sterility issues

    Results RNA, LLC is recalling Lubrisine eye drops nationwide due to lack of sterility assurance and the presence of undeclared colloidal silver.

    Product
    Lubrisine eye drops (polyethylene glycol 400 0.4% and Propylene glycol 0.3%), 30 ML bottle, Manufactured and Distributed by: Results RNA, LLC, 1272 S 1380 W., Orem, UT 84058, UPC 7 9238230723 4
    Category
    Drug
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-0726-2019·2018-12-26

    Marich Recalls Milk Chocolate Maltballs Due to Undeclared Macadamia Nuts

    Marich Confectionery is recalling 15 lb cases of Milk Chocolate Maltballs because a customer found undeclared macadamia nuts in the shipment.

    Product
    Milk Chocolate Maltballs: NET Wt. 15 lbs. Item number 992 Case UPC 00797817-00992-9 Allergy Information: This product contains Wheat, milk and soy and may contain peanuts and tree nuts.
    Category
    Food
    Distribution
    23 states
  • SevereFDA (Devices)·Z-0497-2019·2018-12-26

    COVIDIEN Recalls Puritan Bennett 980 Ventilators Due to Software Update Issues

    COVIDIEN LLC is recalling 9,593 Puritan Bennett 980 ventilators worldwide due to a software update affecting external USB drive performance and GUI functionality.

    Product
    Puritan Bennett 980 (PB980) ventilator series: Puritan Bennett" 980 Pediatric Adult Ventilator Puritan Bennett" 980 Neonatal Ventilator Puritan Bennett" 980 Universal Ventilator Product Usage: The Puritan Bennett 980 Series Ventilator is designed for use on patient…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0337-2019·2018-12-26

    Tris Pharma Recalls Infants' Ibuprofen Due to Higher Concentration

    Tris Pharma is recalling specific lots of Infants' Ibuprofen because they may contain a higher concentration of the active ingredient.

    Product
    Infants' Ibuprofen, Concentrated Ibuprofen Oral Suspension, USP, (NSAID), 50 mg per 1.25 mL, Dye Free, Non-staining Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by: CVS Pharmacy, Inc., One CVS Drive, Woonsocket, RI 02895, UPC 0 50428 39338 3.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0626-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Antenna Due to Tip Disengagement

    FDA is recalling specific lots of the Covidien Emprint Short Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft during use, potentially remaining in the patient.

    Product
    Covidien Emprint Short Percutaneous Antenna with Thermosphere Technology, Material CA15L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0336-2019·2018-12-26

    Tris Pharma Recalls Superpotent Infants' Ibuprofen Suspension

    Tris Pharma is recalling 19,488 bottles of Infants' Ibuprofen due to potential higher-than-labeled ibuprofen concentrations.

    Product
    Infants' Ibuprofen, Concentrated Ibuprofen Oral Suspension, USP, (NSAID), 50 mg per 1.25 mL, Dye-Free Non-Staining Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by Family Dollar Services, Inc., 10301 Monroe Road, Matthews, NC 28105, NDC 55319-250-23, UPC 0 32251 03374 2.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0335-2019·2018-12-26

    Tris Pharma Recalls Infants' Ibuprofen Due to Higher Concentration

    Tris Pharma is recalling specific lots of infants' ibuprofen oral suspension because they may contain a higher concentration of the active ingredient.

    Product
    infants* IBUPROFEN, Concentrated Ibuprofen Oral Suspension, USP (NSAID), 50 mg per 1.25 mL, Dye-Free Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by Wal-Mart Stores, Inc., Bentonville, AR 72716, NDC 49035-125-23, UPC 0 78742 02016 7.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0333-2019·2018-12-26

    Pharmedium Recalls Sub-Potent Fentanyl and Ropivacaine Injection Syringes

    Pharmedium Services, LLC is voluntarily recalling 295 syringes of a fentanyl and ropivacaine injection that were found to be sub-potent.

    Product
    Fentanyl Citrate 2 mcg per mL (100 mcg per 50 mL) and Ropivacaine HCl 0.1% in Sodium Chloride 0.9%, Injection, 50 mL total volume in a 60 mL BD Syringe, Rx Only, PharMEDium Services, LLC. 913 N. Davis Ave. Cleveland, MS 38732 NDC 61553-644-75.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0627-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Ablation Antenna Due to Tip Disengagement

    FDA is recalling the Covidien Emprint Standard Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft, potentially remaining in the patient.

    Product
    Covidien Emprint Standard Percutaneous Antenna with Thermosphere Technology, CA20L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0338-2019·2018-12-26

    Gordon Laboratories Recalls Monsel's Solution Due to High Iron Levels

    Gordon Laboratories is recalling specific batches of Monsel's (Ferric Subsulfate) Solution because they contain higher levels of iron than labeled.

    Product
    Monsel's (Ferric Subsulfate) Solution, 8 mL amber glass bottle, packaged as one dozen bottles with applicators per box, Rx only, Gordon Laboratories, Upper Darby, PA 19082, NDC 10481-0112-8.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0625-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Antenna Due to Tip Disengagement

    FDA is recalling specific lots of the Covidien Emprint Long Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft, potentially remaining in the patient.

    Product
    Covidien Emprint Long Percutaneous Antenna with Thermosphere Technology, Material CA30L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide