The Recall Desk

State

Indiana product recalls

72,940 recalls have nationwide distribution and so reach Indiana. 9,555 additional recalls listed Indiana specifically in their distribution scope.

What the numbers show

Total
9,555
Critical
1,903
Severe
2,136
Most recent
2026-09-09

Of the 9,555 recalls naming Indiana we have scored against our rubric, 1,903 (20%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,136 (22%) are Severe.

These figures cover only the 9,555 recalls whose distribution notice names Indiana specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

4376–4400 of 82495

  • HighNHTSA·25V831000·2025-12-01

    2025 Lincoln Navigator Rear Lightbar Cracks May Disable Reverse Lights

    Ford is recalling certain 2025 Lincoln Navigator vehicles. The rear lightbar may develop cracks allowing moisture accumulation, potentially disabling reverse lights and reducing visibility when backing up.

    Product
    LINCOLN — LINCOLN NAVIGATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V823000·2025-12-01

    2025 Ford Expedition and Other Models Recalled for Brake Booster Malfunction

    Ford is recalling 679 2025 Expedition, Ranger, F-150, Bronco, and Navigator vehicles due to a potential Electronic Brake Booster malfunction that can cause loss of power brake assist, increasing crash risk.

    Product
    FORD — FORD, LINCOLN F-150, EXPEDITION, BRONCO, RANGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V826000·2025-12-01

    2025-2026 RAM Pickup Trucks: Blank Instrument Panel Display Software Error

    Chrysler is recalling 2025-2026 RAM pickup trucks (1500, 2500, 3500, 4500, 5500) because a software error causes the instrument panel display to go blank, preventing drivers from seeing critical warning lights and gear selection.

    Product
    RAM — RAM 1500, 2500, 3500, 4500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V833000·2025-12-01

    Genesis G90 Models: Highway Drive Assist Braking Malfunction Recall

    Hyundai is recalling 2023-2026 Genesis G90 vehicles because the Highway Drive Assist radar may falsely detect another vehicle, causing sudden braking that increases crash risk.

    Product
    GENESIS — GENESIS G90
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V825000·2025-12-01

    KTM and Husqvarna motorcycles recalled for engine control software stalling defect

    KTM and Husqvarna are recalling certain 2024-2025 motorcycles because faulty engine control software may cause the engine to stall at low RPMs, creating a risk of crashes.

    Product
    KTM — KTM, HUSQVARNA 390 SMC R, 390 ENDURO R, 390 ADVENTURE X, VITPILEN 401
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V822000·2025-11-28

    Nova Bus Recalls LFS Transit Buses Due to Cooling Pump Defect

    Nova Bus is recalling 2021 and 2024-2025 LFS transit buses because a loose impeller shaft may cause the cooling pump to fail, potentially leading to a loss of drive power and increased crash risk.

    Product
    NOVA BUS — NOVA BUS LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0430-2026·2025-11-26

    Infusion pump modules recalled because drops can damage the bezel assembly

    CareFusion is recalling 2,574,396 BD Alaris Infusion Pump Modules 8100 because a dropped or jarred pump can suffer bezel damage causing under-infusion, over-infusion or unregulated flow.

    Product
    BD Alaris infusion Pump Module 8100, REF: 8100; KIT, BEZEL ASSY 8100BD, REF: 49000437; KIT ASSY ONE PIECE BEZEL 8100, REF: 49000270. Used with the following new and updated documents: BD Alaris Infusion System Inspection Safety Reminder, Part: BD-163124, Revision: 00; Clean
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V820000·2025-11-26

    Altec Recalls 2025 LR8 Series Vehicles Due to Bolt Failure Risk

    Altec is recalling 2025 LR8 Series vehicles because improperly formed lockbolts may fail, potentially causing the elevator sub-base to separate from the truck frame.

    Product
    ALTEC — ALTEC LR8 SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26120·2025-11-26

    Butane camping stoves recalled after 26 explosions and 16 burn injuries

    About 201,000 Ozark Trail tabletop 1-burner butane camping stoves are being recalled after 26 reports of the stoves exploding or catching fire, including 16 injuries.

    Product
    Ozark Trail Tabletop 1-Burner Butane Camping Stoves
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0521-2026·2025-11-26

    General surgery and knee kits recalled over smoke pencil activation defect

    Medline is recalling 20,941 general surgery, laparoscopy and total knee convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) GENERAL LAPAROSCOPY, REF CDS930027W; 2) GENERAL MAJOR CDS, REF CDS980245X; 3) BASIC GENERAL CDS, REF CDS980566F; 4) TOTAL KNEE CDS, REF CDS982823R; 5) BASIC CDS, REF CDS982936U; 6) UPPER EXTREMITY CDS, REF CDS983907M; 7) MAJO
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0513-2026·2025-11-26

    Vascular and open heart kits recalled over smoke pencils that may activate

    Medline is recalling 5,133 vascular, carotid and open heart convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) GENERAL AAA #11-RF, REF CDS840261AB; 2) CAROTID ENDARTERECTOMY CDS-LF, REF CDS983637I; 3) PERIPHERAL VASCULAR CDS, REF CDS983723J; 4) ACH OPEN HEART, REF CDS983773J; 5) VASCULAR, REF CDS984255K; 6) OPEN HEART CHILDRENS PACK-LF,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·26114·2025-11-26

    Pressure mounted safety gates recalled over a torso sized opening

    About 100 Ikuso pressure-mounted safety gates are being recalled because a child's torso can fit through the opening between the gate slat and the side wall.

    Product
    Ikuso Safety Gates
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0529-2026·2025-11-26

    Minor eye trays recalled over smoke pencils that may stay active

    Medline is recalling 345 Minor Eye Tray #81 convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) MINOR EYE TRAY #81, REF DYNJ27466S; 2) MINOR EYE TRAY #81, REF DYNJ27466T.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0511-2026·2025-11-26

    Local basic kits recalled over smoke pencils that may stay active

    Medline is recalling 48 LOCAL BASIC convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as LOCAL BASIC, REF DYNJ34418M
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0504-2026·2025-11-26

    Luer tip caps recalled after trays failed routine biocompatibility testing

    Becton Dickinson is recalling 4,180,000 BD Luer Tip Caps after internal testing confirmed that certain device trays failed routine biocompatibility testing.

    Product
    BD Luer Tip Caps; Catalog Number(s) or Model Number(s): 308341;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0533-2026·2025-11-26

    Hemostasis valves recalled because the valve cap may remain depressed

    Merit Medical is recalling 217,141 PhD Hemostasis Valves because a manufacturing defect can leave the valve cap depressed, leading to potential leakage and possible hemorrhage.

    Product
    PhD Hemostasis Valve, REF: IN4802/K, IN4802/T, IN4918/A, IN7802/C, IN8802/C, IN9802, IN9802/A, K05-02166B, K05T-02138A, K12T-10798A, MAP800/B, MAP800/T, MAP801/B, MAP802/B, MAP802/CNB, MAP802/T, MAP804/B, MAP852/B, SKY1802.
    Category
    Medical Device
    Distribution
    49 states
  • HighFDA (Devices)·Z-0526-2026·2025-11-26

    Caesarean section kits recalled over smoke pencils that may activate

    Medline is recalling 11,032 C-section convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) C-SECTION OR 30 CDS, REF CDS820075W; 2) C-SECTION, REF CDS984261J; 3) C-SECTION CDS, REF CDS985282F; 4) C-SECTION PACK, REF DYNJ02577D; 5) C-SECTION PACK-LF, REF DYNJ0536924U; 6) C-SECTION PACK-LF, REF DYNJ0551169V; 7) C-SECT
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0509-2026·2025-11-26

    ECMO consoles recalled after eleven reports of a blank touchscreen error

    Medtronic is recalling 167 MC3 VitalFlow Consoles after eleven reports of an E70 error code that leaves the touchscreen blank for up to two minutes during operation.

    Product
    MC3 VitalFlow Console, REF 58100; Blood pump of ecmo
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0542-2026·2025-11-26

    Cell morphology analyzers recalled over barcodes read from the previous slide

    Cellavision is recalling 688 DI-60 automated digital cell morphology analyzers because the barcode reader may read the previous slide's barcode, misattributing diagnostic results.

    Product
    REF: CC286297 or BS737162 Automated Digital Cell Morphology analyzer DI-60, IVD in conjunction with a Honeywell Vuquest or Jadk FM-5 barcode reader component.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·26125·2025-11-26

    Hair dryers recalled for lacking an immersion protection device

    About 740 MyOnlyStyler Root Booster Hair Dryers are being recalled because they lack an immersion protection device, posing an electrocution risk if dropped in water.

    Product
    MyOnlyStyler Root Booster Hair Dryers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26113·2025-11-26

    Macardac baby loungers recalled over fall and entrapment hazards

    About 700 Macardac baby loungers are being recalled because the sides are too low to contain an infant, the foot openings are too wide, and the loungers have no stand.

    Product
    Macardac Baby Loungers
    Category
    Consumer Product
    Distribution
    Distributed nationwide