The Recall Desk

State

Hawaii product recalls

72,992 recalls have nationwide distribution and so reach Hawaii. 2,767 additional recalls listed Hawaii specifically in their distribution scope.

What the numbers show

Total
2,767
Critical
333
Severe
567
Most recent
2026-09-16

Of the 2,767 recalls naming Hawaii we have scored against our rubric, 333 (12%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 567 (20%) are Severe.

These figures cover only the 2,767 recalls whose distribution notice names Hawaii specifically. The 72,992 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

7451–7475 of 75759

  • HighCPSC·25179·2025-03-13

    Meijer Recalls Konwin Desktop Heaters Due to Fire and Burn Hazards

    Meijer is recalling about 6,050 Konwin desktop heaters because the fan can fail to turn on, causing the unit to overheat and ignite. The company received eight reports of fans burning and melting, but no injuries have been reported.

    Product
    Konwin Desktop Heaters
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·25177·2025-03-13

    BMC recalls Kaius 01 bicycles and framesets for fork separation hazard

    BMC recalled about 1,300 Kaius 01 bicycles because the fork steerer tube can crack and separate during use, posing a fall hazard. No injuries reported; consumers should stop using them and contact dealers for free fork replacement.

    Product
    BMC-branded Kaius 01 bicycles and framesets
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·25181·2025-03-13

    Climbing Harness Recalled for Potential Degradation and Fall Risk

    Black Diamond Equipment recalls BD Vision climbing harnesses due to potential degradation that could cause harness failure and falls. No injuries have been reported to date.

    Product
    BD Vision Climbing Harness
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·25180·2025-03-13

    Chews Life Recalls Silicone Rosary and Decade Teethers for Choking Hazard

    About 5,700 Chews Life Silicone Rosary and Decade teethers are being recalled because the safety snap clasp can detach, posing a choking hazard to infants. No injuries have been reported.

    Product
    Silicone Rosary and Decade teethers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·25178·2025-03-13

    Retractable Safety Gates Recalled for Risk of Child Entrapment

    HabiLife Direct retractable safety gates (model SG021) are recalled due to an entrapment hazard where children's torsos can fit through gaps between the gate and floor. About 880 units sold on Amazon from September 2024 through January 2025.

    Product
    Retractable Safety Gates
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1257-2025·2025-03-12

    Insulin pump recall: Medtronic Paradigm models malfunction during airplane flight

    Medtronic MiniMed's Paradigm insulin pumps can malfunction during airplane flight due to air pressure changes, potentially causing dangerously high or low blood sugar levels that could be fatal.

    Product
    Paradigm insulin pump, REF: MMT-754
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1244-2025·2025-03-12

    Rotarex Atherectomy Catheter Recalled for Helix Fracture Risk

    Bard is recalling Rotarex Atherectomy System catheters due to potential helix fracture or breakage that could cause vessel injury and severe bleeding. Updated instructions are being distributed to clarify procedural steps to reduce this risk.

    Product
    Rotarex Atherectomy System and Instructions for Use, BD SET Rotarex: S 6 F x 110 cm, REF: 80236; S 6 F x 135 cm, REF: 80237; S 8 F x 85 cm, REF: 80238; S 8 F x 110 cm, REF: 80239
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0607-2025·2025-03-12

    Frozen Sugar Cookie Dough Recalled for Undeclared Egg Allergen

    Amazon Fresh Bake at Home Jumbo Sugar Cookie dough is being recalled due to undeclared egg. Consumers with egg allergies should not consume this product.

    Product
    ASIN B0CY2RDW5T, Amazon Fresh brand, Bake at Home Jumbo Sugar Cookie 30oz, product is frozen dough, and packaged in flexible plastic bag. UPC 446472006995.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0606-2025·2025-03-12

    Amazon Fresh Jumbo Sugar Cookies recalled for undeclared egg allergen

    Amazon Retail LLC is recalling Amazon Fresh Jumbo Sugar Cookies nationwide due to undeclared egg, a major allergen. Consumers with egg allergies should not consume the affected cookies.

    Product
    ASIN B084PZ7K98, Amazon Fresh Jumbo Sugar Cookie, 27 oz (12 count), product is baked and packaged in flexible plastic bag. 4-day shelf life. UPC 465712007998. ASIN B084PX9V31, Amazon Fresh Jumbo Sugar Cookie, 2.3 oz (1 count), product is baked and sold from open pastry tray in s
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0605-2025·2025-03-12

    Spanish rolls recalled for undeclared milk allergen in Hawaii

    Jesse's Bakery is recalling Pan de Sal (Spanish rolls) sold in Hawaii due to undeclared milk. The product label does not declare milk, but the rolls contain milk, posing a risk to consumers with milk allergies.

    Product
    Pan de Sal (Spanish Rolls), net wt. 9oz, product is packaged as 6 rolls in a flexible poly bag with printed label on bag. Product label states Jesse s BAKERY, INC 1101 N. King Street Phone: 842-1120/842-1121 Honolulu, Hawaii 96817. UPC 0 38511 00703 4. The affected label declare
    Category
    Food
    Distribution
    1 state
  • SevereNHTSA·25V046000·2025-03-12

    Freightliner Recalls eCascadia and eM2 Trucks for Power Loss Risk

    Daimler Trucks North America is recalling 2020-2026 Freightliner eCascadia and eM2 trucks because a faulty power module may cause a loss of drive power, increasing crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER E-CASCADIA, EM2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1263-2025·2025-03-12

    Insulin Pump Recalled for Abnormal Delivery During Flight Pressure Changes

    Medtronic MiniMed 720G insulin pumps may malfunction during airplane travel due to air pressure changes, causing abnormal insulin doses that can lead to severe low or high blood sugar emergencies.

    Product
    MiniMed insulin pump, REF: 720G (MMT-1809, MMT-1810, MMT-1859, MMT-1860, MMT-1867)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1253-2025·2025-03-12

    Baxter Sigma Spectrum Infusion System Recalled for Missing Mounting Screws

    Baxter Healthcare is recalling 66 units of Sigma Spectrum Infusion System (V6) due to potential missing motor mounting screws that may have occurred during servicing. Missing screws could affect the device's operation.

    Product
    Baxter Sigma Spectrum Infusion System (V6 Platform), Product Code 35700BAX
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V152000·2025-03-12

    Shyft Recalls 2025 Utilimaster Upfit Vehicles for Loose Seat Bolts

    Shyft Group is recalling 2025 Utilimaster Upfit vehicles because passenger jump seat mounting bolts may not be properly tightened, increasing injury risk in a crash.

    Product
    UTILIMASTER — UTILIMASTER UPFIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V154000·2025-03-12

    BMW X3 rear brake hoses may leak and disable rear braking

    BMW is recalling certain 2025 X3 30 xDrive and X3 M50 xDrive vehicles because the rear brake hoses may leak, causing a loss of rear brake function, ABS and stability control.

    Product
    BMW — BMW X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1245-2025·2025-03-12

    Medtronic Pipeline Vantage Embolization Device Recall for Structural Deformation Risk

    Medtronic is recalling approximately 18,245 unused Pipeline Vantage embolization devices due to incomplete wall apposition and braid deformation that may lead to thrombosis and serious adverse events.

    Product
    Medtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-027-350-12, PED3-027-350-14, PED3-027-350-16, PED3-027-350-20, PED3-027-350-25, PED3-027-400-12, PED3-027-400-14, PED3-027-400-16, PED3-027-400-18, PED3-027-400-20, PED3-027-400-25, PED3-027-400-30,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1254-2025·2025-03-12

    Baxter Spectrum IQ Infusion System may have missing motor mounting screws

    Baxter Spectrum IQ Infusion Systems may lack motor mounting screws due to a servicing defect. The FDA Class I recall affects 323 units distributed nationwide.

    Product
    Baxter Spectrum IQ Infusion System with Dose IQ Safety Software, Product Code 3570009
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1246-2025·2025-03-12

    Medtronic Pipeline Vantage device recall: deformation may cause blood clots

    The Pipeline Vantage Embolization Device may malfunction, with the braid deforming or not positioning correctly, potentially causing blood clots. Approximately 7,820 units are affected worldwide.

    Product
    Medtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-021-350-16, PED3-021-250-14, PED3-021-350-20, PED3-021-250-20, PED3-021-300-16, PED3-021-300-20, PED3-021-275-12, PED3-021-275-16, PED3-021-325-12, PED3-021-325-14, PED3-021-325-16, PED3-021-325-20,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1259-2025·2025-03-12

    MiniMed Insulin Pumps Recalled for Abnormal Insulin Delivery During Flight

    MiniMed insulin pumps may deliver abnormal insulin doses during aircraft takeoff and landing due to air pressure changes, risking severe blood sugar fluctuations, seizures, and potentially fatal complications.

    Product
    MiniMed insulin pump, REF: 630G (MMT-1714, MMT-1715, MMT-1754, MMT-1755)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1269-2025·2025-03-12

    CircuitGuard Bacterial/Viral Filter Recalled for Plastic Connector Obstruction

    Kung Shin Plastics is recalling 30,000 units of CircuitGuard Bacterial/Viral Filter with Elbow (Model SK200FPE/7056) due to plastic occlusion in the connector that prevents airflow and causes ventilation bag malfunction, risking oxygen deprivation and respiratory distress.

    Product
    CircuitGuard Bacterial/Viral Filter with Elbow (Model/Catalogue number: SK200FPE / 7056)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1255-2025·2025-03-12

    Medtronic Paradigm insulin pumps may deliver incorrect doses during flight

    Medtronic MiniMed insulin pumps may deliver abnormally high or low insulin doses in response to air pressure changes during airplane takeoff and landing, potentially causing severe hypoglycemia or hyperglycemia.

    Product
    Paradigm REF: MMT-712 and MMT-715
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1294-2025·2025-03-12

    Tissue Approximation System zip-ties at risk of breaking during implantation

    TAS Medical is recalling Tissue Approximation System models because tissue approximation straps (zip-ties) may break before or during surgery. Undetected breaks could lead to hernia recurrence requiring additional corrective surgery.

    Product
    TISSUE APPROXIMATION SYSTEM (TAS), Models T-4000, T-5000, T-LAP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1262-2025·2025-03-12

    Medtronic MiniMed insulin pump recalled for abnormal delivery during air pressure changes

    Medtronic MiniMed insulin pumps may deliver insulin abnormally during airplane take-off or landing due to air pressure changes, risking severe low or high blood sugar emergencies.

    Product
    MiniMed insulin pump, REF: 700G (MMT-1801, MMT-1805, MMT-1850, MMT-1851)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1258-2025·2025-03-12

    MiniMed Insulin Pumps Recalled for Abnormal Delivery During Air Travel

    Medtronic recalled MiniMed insulin pumps due to abnormal delivery caused by air pressure changes during airplane flights. The defect can cause severe hypoglycemia or hyperglycemia, potentially leading to seizure, coma, or death.

    Product
    MiniMed insulin pump, REF: 620G (MMT-1750)
    Category
    Medical Device
    Distribution
    Distributed nationwide