The Recall Desk

State

Connecticut product recalls

72,940 recalls have nationwide distribution and so reach Connecticut. 6,566 additional recalls listed Connecticut specifically in their distribution scope.

What the numbers show

Total
6,566
Critical
838
Severe
1,588
Most recent
2026-09-09

Of the 6,566 recalls naming Connecticut we have scored against our rubric, 838 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,588 (24%) are Severe.

These figures cover only the 6,566 recalls whose distribution notice names Connecticut specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

3976–4000 of 79506

  • SevereNHTSA·25E091000·2025-12-18

    Hyundai Recalls Mobis Tow Hitch Harnesses Due to Electrical Fire Risk

    Hyundai is recalling specific Mobis tow hitch harnesses because incorrect installation may allow water entry, causing lighting failures or electrical short circuits.

    Product
    TRAILER HITCHES recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V882000·2025-12-18

    Ram truck software error may prevent driver air bag deployment

    Chrysler is recalling certain 2025 Ram 2500, 3500, 4500 and 5500 trucks because a software error may stop the driver's air bag or seat belt pretensioner deploying in a crash and disable stability control.

    Product
    RAM — RAM 2500, 4500, 5500, 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26152·2025-12-18

    Electric fat tire trikes recalled after frames broke near a weld

    About 400 Pedego Fat Tire Trikes are being recalled because the frame can develop a hairline fracture near a weld. Pedego has received 16 reports of frames breaking, including one leg laceration.

    Product
    Fat Tire Trikes
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V892000·2025-12-18

    Honda CB1000SP pistons may fail causing rear wheel lockup or oil leak

    Honda is recalling certain 2025 CB1000SP motorcycles because improperly manufactured pistons and piston rings can lead to rod bearing failure, rear wheel lockup, or oil leaking onto the rear tire.

    Product
    HONDA — HONDA CB1000SP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V881000·2025-12-18

    Ford Recalls Maverick and Escape Hybrids for Software Defect

    Ford is recalling 2022-2024 Maverick Hybrid and 2020 Escape Hybrid vehicles because a software defect may cause the vehicle to shift into neutral unexpectedly, increasing crash risk.

    Product
    FORD — FORD MAVERICK HYBRID, ESCAPE HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V893000·2025-12-18

    Hyundai Tucson tow hitch harness may let water reach the module

    Hyundai is recalling certain 2022-2024 Tucson vehicles with an optional Mobis tow hitch wiring harness because incorrect installation may allow water into the control module.

    Product
    HYUNDAI — HYUNDAI TUCSON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26160·2025-12-18

    Portable bed rails recalled over entrapment and asphyxiation hazards

    About 12,000 JOKOSIS portable bed rails, model HC0262, are being recalled because users can become entrapped within the rail or between the rail and the mattress.

    Product
    JOKOSIS Portable Bed Rails
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·25V888000·2025-12-18

    Ford Bronco rearview image may remain displayed after backing ends

    Ford is recalling certain 2021-2022 Bronco vehicles previously repaired under recall 23V165, because the rearview camera image may still be displayed after a backing event has ended.

    Product
    FORD — FORD BRONCO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26155·2025-12-18

    Chandeliers recalled because an improperly threaded component lets fixtures fall

    About 260 Currey & Company Electra chandeliers are being recalled because the component connecting the fixture to the ceiling mount is not threaded properly and the fixture can fall.

    Product
    Electra Chandelier and Electra Three Tier Chandelier light fixtures
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·25V878000·2025-12-18

    2025–2026 Chevrolet Equinox EV Pedestrian Alert System Defect

    General Motors is recalling 2025–2026 Chevrolet Equinox EV vehicles because the pedestrian alert sound system may not produce sufficient volume change between stopped and low-speed operation, failing to meet federal safety standards.

    Product
    CHEVROLET — CHEVROLET EQUINOX EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26156·2025-12-18

    Eighteen-drawer fabric dressers recalled over tip over and entrapment hazards

    About 2,800 17 Stories Furniture 18-Drawer Dressers are being recalled because they are unstable if not anchored to the wall and violate the mandatory standard required by the STURDY Act.

    Product
    17 Stories Furniture 18-Drawer Dressers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26162·2025-12-18

    SereneLife above-ground pools recalled over a strap that creates a foothold

    About 80 SereneLife above-ground pools 48 inches and taller, models SLPORND15 and SLPORND18, are being recalled because a compression strap may create a foothold allowing a child to access the pool.

    Product
    SereneLife brand 48-inch and taller above-ground pools
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26161·2025-12-18

    Power strips recalled for lacking supplementary overcurrent protection

    About 11,200 ANNQUAN power strips are being recalled because they do not contain supplementary overcurrent protection, creating a fire risk if overloaded.

    Product
    ANNQUAN Power Strips, Models EX-D112-05 and EX-D106-25
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26163·2025-12-18

    Above-ground pools recalled because a compression strap can create a foothold

    About 13,400 Blue Wave above-ground pools 48 inches and taller are being recalled because the compression strap around the outside of the pool legs may create a foothold for children.

    Product
    Blue Wave brand 48-inch and taller above-ground pools
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26159·2025-12-18

    Nine-drawer fabric dressers recalled over tip over and entrapment hazards

    About 4,740 KKL Fabric 9-Drawer Dressers are being recalled because they are unstable if not anchored to the wall and violate the mandatory standard required by the STURDY Act.

    Product
    KKL Fabric 9-Drawer Dressers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26153·2025-12-18

    Eight-drawer fabric dressers recalled over tip over and entrapment hazards

    About 16,800 Furnulem 8-Drawer Dressers are being recalled because they are unstable if not anchored to the wall and violate the mandatory standard required by the STURDY Act.

    Product
    Furnulem 8-Drawer Dressers
    Category
    Consumer Product
    Distribution
    Distributed nationwide