  • HighNHTSA·24V348000·2024-05-16

    2024 Lamborghini Urus Hood Latch May Separate While Driving

    Lamborghini is recalling 2023-2024 Urus Performante and Urus S vehicles because the hood latch striker may separate, causing the hood to open or detach while driving and create a road hazard.

    Product
    LAMBORGHINI — LAMBORGHINI URUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24236·2024-05-16

    CHZHVAN Combination Smoke and Carbon Monoxide Detectors Recalled for Failure to Alert

    CHZHVAN combination smoke and carbon monoxide detectors can fail to activate and may not alert users to a fire. About 6,800 units sold online via Amazon.com from August 2023 through January 2024 are affected.

    Product
    CHZHVAN Combination Smoke and Carbon Monoxide Detectors
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V346000·2024-05-16

    2024 Jeep Grand Cherokee: Missing Bumper Foam May Prevent Airbag Deployment

    Certain 2024 Jeep Grand Cherokees may be missing foam in the front bumper, which could prevent the front airbags from deploying during a crash. Dealers will install the foam at no cost.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V347000·2024-05-16

    Custom Truck Recalls 2020 Ford F-550 for Electrical Fire Risk

    Custom Truck is recalling one 2020 Ford F-550 because a wiring fault may cause electrical circuits to overheat and increase fire risk.

    Product
    CUSTOM TRUCK & BODY WORKS — CUSTOM TRUCK & BODY WORKS FORD F-550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24237·2024-05-16

    Kano Laboratories Recalls Super Lube Products for Non-Child-Resistant Packaging

    Kano Laboratories is recalling Super Lube Syncopen Synthetic Penetrant, Fire Resistant Hydraulic Fluid, and Metal Protectant and Corrosion Inhibitor products in sizes of five gallons or less because the packaging is not child-resistant as required by law, posing a poisoning risk to young children.

    Product
    Super Lube Syncopen Synthetic Penetrant, Super Lube Fire Resistant Hydraulic Fluid, and Super Lube Metal Protectant and Corrosion Inhibitor (consumer sizes of five gallons or less)
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V349000·2024-05-16

    Mazda Recalls 2024 CX-90 Vehicles for Automatic Braking Defect

    Mazda is recalling 2024 CX-90 vehicles because the automatic emergency braking system may falsely detect objects, causing sudden braking and increasing crash risk.

    Product
    MAZDA — MAZDA CX-90
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V342000·2024-05-15

    Morbark Brush Chippers Recalled for Fuel Line Fire Risk

    Alamo Group is recalling 2023-2024 Morbark brush chippers because fuel lines may lack the required pressure rating, creating a fire hazard.

    Product
    MORBARK — MORBARK EEGER BEEVER 1922, EEGER BEEVER 2131, EEGER BEEVER 1821
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V343000·2024-05-15

    Porsche Recalls 2024 718 Models Due to Shift Cable Installation Issue

    Porsche is recalling 2024 718 Cayman and Boxster vehicles because a safety clip may not be installed properly, potentially preventing the transmission from locking in park.

    Product
    PORSCHE — PORSCHE 718 CAYMAN, 718 BOXSTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V345000·2024-05-15

    BMW 2024-2025 X5, X6, X7, XM, and Alpina XB7 Seat Belt Detection System Defect

    BMW recalls certain 2024-2025 X5, X6, X7, XM, and Alpina XB7 models due to a seat belt detection system defect that may fail to alert drivers of unbuckled passengers or allow proper deployment of the supplemental restraint system.

    Product
    BMW — BMW ALPINA XB7, X6, XM, X5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0485-2024·2024-05-15

    Prescription Drug Javygtor Recalled for Sub-Potency and Powder Discoloration

    Dr. Reddy's Laboratories is recalling Javygtor powder packets nationwide due to powder discoloration and sub-potency. The recall affects 17,332 cartons with multiple lot numbers.

    Product
    JAVYGTOR — JAVYGTOR (SAPROPTERIN DIHYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1609-2024·2024-05-15

    Insulin pump app may crash and drain battery, risking insulin delivery interruption

    Tandem's t:connect app version 2.7+ may crash repeatedly, draining the insulin pump battery faster than expected and potentially interrupting insulin delivery.

    Product
    t:connect mobile app used in conjunction with t:slim X2 insulin pump with Control-IQ technology
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V341000·2024-05-15

    Navistar Recalls 2024-2025 IC Bus School Buses for Brake Defect

    Navistar is recalling 2024-2025 IC Bus school buses because a faulty valve module may cause park brake failure or unexpected engagement.

    Product
    IC BUS — IC BUS CESB, CE SBUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1776-2024·2024-05-15

    Stealth S8 neurosurgical navigation software display error affecting surgical guidance

    Medtronic's Stealth S8 surgical navigation software has a display bug that may omit digits, letters, or decimals from critical readings during brain surgery. FDA classified this as Class I due to serious potential surgical errors.

    Product
    Stealth S8 Clinical Software Application, REF: 9735762, CE0344, Rx Only. Used in the StealthStation System as an aid for locating anatomical structures in either open or percutaneous neurosurgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1733-2024·2024-05-15

    Hologic BioZorb Bioabsorbable Markers Recalled for Adverse Events

    Hologic is recalling BioZorb Marker bioabsorbable surgical markers due to reported adverse events including infection, pain, device migration, and erosion. FDA classified this as Class I, affecting 53,492 units nationwide.

    Product
    BioZorb Marker-BioZorb 3D Bioabsorbable Marker-Intended Use radiographic marking of sites in soft tissue. 1) F0405 BioZorb Marker 4cm x 5cm 2) F0404 BioZorb Marker 4cm x 4cm 3) F0331 BioZorb Marker 1cm x 3cm x 3cm 4) F0231 BioZorb Marker 1cm x 3cm x 2cm 5) F0221 BioZorb…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1730-2024·2024-05-15

    Vyaire Twin Tube Sample Line Nozzle Separation Recall

    Vyaire Medical recalls Twin Tube sample line 240 cm devices (Model V-707327) due to potential nozzle separation during patient use. All lots manufactured prior to June 2023 are potentially affected.

    Product
    Vyaire Medical GmbH, Vyaire Twin Tube sample line 240 cm, Model Number V-707327; The TwinTube sample line 240cm is used in the Vyntus CPX. The TwinTube sample line 240cm is connected to the adapter for DVT. Twin Tube Probenschlauch (707004), which is sold outside the US only.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0486-2024·2024-05-15

    Sapropterin Dihydrochloride Powder for Oral Solution Recalled Due to Sub-Potency

    Dr. Reddy's Laboratories is recalling 2,402 cartons of Sapropterin Dihydrochloride Powder 100mg due to sub-potency associated with powder discoloration. The affected lot (T2200352) was distributed nationwide.

    Product
    Sapropterin Dihydrochloride Powder for Oral Solution 100mg, 30 individual packets per carton, Rx Only, Distributor: Dr. Reddy's Laboratories Inc., Princeton, NJ 08540, Made in India, NDC 43598-477-30.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighNHTSA·24V340000·2024-05-15

    2025 MINI Countryman Rear Armrest May Detach During Airbag Deployment

    BMW is recalling 9 2025 MINI Countryman vehicles because the armrest support bracket on the rear side door panel may be improperly secured and detach during an airbag deployment, potentially striking occupants or interfering with airbag function.

    Product
    MINI — MINI COUNTRYMAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0489-2024·2024-05-15

    TraMADol HCl 50 mg Tablets Recalled for Foreign Baclofen Tablets

    RemedyRepack Inc. is recalling TraMADol HCl 50 mg tablets nationwide after a pharmacist discovered a baclofen tablet in a tramadol bottle. Taking the wrong medication poses serious health risks.

    Product
    TraMADol HCl 50 mg Tablet, Packaged as (a) 30-count blister pack, NDC 70518-3824-00; (b) 90-count blister pack, NDC 70518-3824-02; (a) 180-count blister pack, NDC 70518-3824-03; RX ONLY, MFG: Advagen Pharma Limited, Plainsboro. NJ 08536, Repackaged by: RemedyRepack Inc.…
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1219-2024·2024-05-15

    FDA Recalls Sacramento Cookie Factory Wine Wafers for Undeclared Milk Allergen

    Sacramento Cookie Factory recalls Original Wine Wafer - Lemon Vanilla cookies in multiple states due to undeclared milk allergen. Consumers with milk allergies should not consume this product.

    Product
    Original Wine Wafer - Lemon Vanilla [Two sizes: retail package of 8 wafers (7 oz) and retail gift package of 2 wafers (2 oz)]
    Category
    Food
    Distribution
    14 states
  • HighFDA (Drugs)·D-0493-2024·2024-05-15

    Prescription antifungal injection product recalled for out-of-specification assay

    Sun Pharmaceutical is recalling Amphotericin B for Injection (50 mg vials) due to out-of-specification assay results. The recall affects 11,016 vials with lot numbers BAE0055A, BAE0056A, and BAE0068A distributed nationwide.

    Product
    AMPHOTERICIN B — AMPHOTERICIN B (AMPHOTERICIN B)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1220-2024·2024-05-15

    Martinelli's Gold Medal Apple Juice Recalled for Elevated Inorganic Arsenic

    S Martinelli & Company is recalling Martinelli's Gold Medal Apple Juice (1 Liter) due to elevated levels of inorganic arsenic. The affected product has Best By dates of March 9, 2026 or March 10, 2026.

    Product
    Martinelli's Gold Medal Apple Juice From U.S. Grown Fresh Apples 1 Liter (33.8 fl oz.) No Additives of Any Kind UPC 0 00 41244 00102 6
    Category
    Food
    Distribution
    35 states
  • HighFDA (Devices)·Z-1781-2024·2024-05-15

    GE Allia IGS Fluoroscopic X-Ray Systems Adhesive Bolt Defect

    GE Healthcare recalled certain Allia IGS and related fluoroscopic x-ray systems due to potential incomplete adhesive on bolts in the gantry assembly, risking detector or tube failure.

    Product
    GE Healthcare Allia IGS 7 OR, Interventional fluoroscopic x-ray systems
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1783-2024·2024-05-15

    GE Healthcare Allia IGS Fluoroscopic Systems Recall: Missing Adhesive

    GE Healthcare recalls Allia IGS and related interventional fluoroscopic x-ray systems due to potentially missing adhesive on bolts. The defect could allow the detector/elevator or x-ray tube in the gantry assembly to fall.

    Product
    GE Healthcare Allia IGS 5 Pulse, Interventional fluoroscopic x-ray systems
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1757-2024·2024-05-15

    Philips 5000 Compact Series Ultrasound Systems pose uncontrolled burn risk

    Philips 5000 Compact Series ultrasound systems may leave unselected transesophageal transducers powered without temperature monitoring, risking patient burns during imaging procedures.

    Product
    5000 Compact Series Ultrasound Systems, Product/REF: 5500 CV/795141, 5500 P/795143, 5500 W/795144, 5500 G/795145, and Product/REF: 5300 W/795146, 5300 P/795147, 5300 G/795148, used with Deluxe and Premium Carts that come with multiport adapters.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V344000·2024-05-15

    2021-2023 Volkswagen ID.4 display software defect increases crash risk

    Certain 2021-2023 Volkswagen ID.4 vehicles experience a software issue causing display failures that hide the speedometer and rearview camera. Dealers will update the software at no cost.

    Product
    VOLKSWAGEN — VOLKSWAGEN ID.4
    Category
    Vehicle
    Distribution
    Distributed nationwide