  • SevereNHTSA·12V105000·2012-03-20

    Gulf Stream Recalls 2001-2005 Recreational Vehicles Due to Wiring Fire Risk

    Gulf Stream is recalling specific 2001-2005 recreational vehicles because unsecured wiring may cause heat and fire. Owners should contact dealers for free repairs.

    Product
    GULF STREAM — GULF STREAM ULTRA, CONQUEST, ENDURA, INDEPENDENCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V128000·2012-03-20

    Webasto Sunroof Glass Debonding Recall for Coach Automotive Vehicles

    Webasto is recalling certain sunroofs installed by Coach Automotive Restyling because the glass can separate from the frame, creating a road hazard.

    Product
    VISIBILITY:SUN/MOON ROOF ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12134·2012-03-20

    Bon Hiver Recalls Freebase Snowboard Bindings Due to Base Plate Fracture Hazard

    Bon Hiver is recalling Freebase snowboard bindings because the base plate can fracture during use, posing a fall hazard. Consumers should stop using the products and return them for a free repair and partial refund.

    Product
    Snowboard Bindings
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V104000·2012-03-19

    Webasto Sunroof Recall Due to Glass Separation Risk

    Webasto is recalling certain sunroofs installed by Cyclone Auto Seat Cover because the glass may separate from the frame, creating a road hazard.

    Product
    VISIBILITY:SUN/MOON ROOF ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V103000·2012-03-19

    Webasto Sunroof Recall Due to Glass Separation Risk

    Webasto is recalling certain sunroofs installed by National Auto Spa because the glass may separate from the frame, creating a road hazard.

    Product
    VISIBILITY:SUN/MOON ROOF ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V215000·2012-03-19

    Tiffin Allegro Motorhomes Recalled for Gear Shift Cable Defect

    Tiffin is recalling 2010-2012 Allegro motorhomes because a gear shift cable may break, causing the gear indicator to display incorrectly and increasing crash risk.

    Product
    TIFFIN — TIFFIN ALLEGRO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12E010000·2012-03-15

    Land Rover Recalls Rear Driveshaft Couplings for Crash Risk

    Jaguar Land Rover is recalling certain rear driveshaft couplings for 1995-2004 Land Rover Discovery and Range Rover Classic vehicles. The parts may fail, causing loss of drive and increasing crash risk.

    Product
    LAND ROVER — LAND ROVER, RANGE ROVER DISCOVERY II, DISCOVERY, CLASSIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12727·2012-03-15

    Kawasaki Recalls Utility Vehicles Due to Fuel Tube Fire Hazard

    Kawasaki is recalling about 3,900 model year 2012 utility vehicles because a fuel tube can scrape against the air cleaner housing, posing a fire hazard.

    Product
    Utility Vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V101000·2012-03-14

    Volvo Recalls 2012 S60 and XC60 for Fuel Line Fire Risk

    Volvo is recalling 2012 S60 and XC60 vehicles because underbody coating may damage fuel lines, causing leaks and increasing fire risk.

    Product
    VOLVO — VOLVO S60, XC60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·12V102000·2012-03-14

    Nissan Titan Recall: Incorrect Tire Placard Seating Capacity Information

    Nissan is recalling certain 2012 Titan vehicles with the Sports Appearance Package because the tire placard displays incorrect seating capacity information, which may lead to vehicle overloading.

    Product
    NISSAN — NISSAN TITAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12131·2012-03-13

    Guidecraft Recalls 4-in-1 Play Theaters Due to Tip-Over Hazard

    Guidecraft is recalling 4-in-1 Dramatic Play Theater Toys because they can tip over, posing an entrapment hazard to young children.

    Product
    4-in-1 Dramatic Play Theater Toys
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V100000·2012-03-13

    Trans Tech Horizon Transit Bus Seat Belt Anchor Recall

    Two 2011 Trans Tech Horizon buses are recalled because seat belt anchorages may not meet federal safety standards, increasing injury risk in a crash.

    Product
    TRANS TECH — TRANS TECH HORIZON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V099000·2012-03-13

    Subaru Forester Recall for Rear Center Seat Belt Defect

    Subaru is recalling 2009-2012 Foresters because the rear center seat belt may not secure child restraints properly, increasing injury risk in a crash.

    Product
    SUBARU — SUBARU FORESTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12132·2012-03-13

    Hydro-Gear Recalls Lawn Tractors Due to Brake Failure Crash Hazard

    Hydro-Gear is recalling about 2,700 Cub Cadet, MTD Gold, and Troy-Bilt lawn tractors because a drive gear failure can cause brake failure, posing a crash hazard.

    Product
    Lawn Tractors
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V096000·2012-03-08

    Mack LEU and MRU Trucks Recalled for Electrical Fire Risk

    Mack is recalling 318 natural gas LEU and MRU trucks because an alternator ground cable defect may cause a vehicle fire during an electrical short.

    Product
    MACK — MACK LEU, MRU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·12129·2012-03-08

    Lenovo Recalls ThinkCentre Desktop Computers Due to Fire Hazard

    Lenovo is recalling about 50,500 ThinkCentre M70z and M90z desktop computers because a power supply defect can overheat and cause a fire.

    Product
    Lenovo ThinkCentre M70z and M90z desktop computers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V097000·2012-03-07

    Ford Recalls 2011 F-650 and F-750 Trucks for Brake Valve Defect

    Ford is recalling 2011 F-650 and F-750 trucks because a brake valve may leak in cold weather, causing continuous braking and potential fire.

    Product
    FORD — FORD F-650, F-750
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V092000·2012-03-07

    Toyota Recalls 2005-2009 Tacoma for Air Bag Cable Defect

    Toyota is recalling 2005-2009 Tacoma vehicles because steering wheel vibration may damage the cable powering the driver's air bag, potentially preventing deployment in a crash.

    Product
    TOYOTA — TOYOTA TACOMA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12128·2012-03-07

    Locker Brand Recalls Rx Lockers Due to Unauthorized Access Risk

    Locker Brand is recalling Rx Lockers because the latch can be forced open, allowing unauthorized access to medicine. No injuries have been reported.

    Product
    Medicine Bottle Storage Containers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·12726·2012-03-07

    BCI Burke Swing Sets Recalled for Fall Hazard

    BCI Burke is recalling about 250 Arch Swing Sets because a welded joint can crack, causing the swing beam to collapse and children to fall.

    Product
    2 3/8 inch Arch Swing Sets
    Category
    Consumer Product
    Distribution
    Distributed nationwide