The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3826–3850 of 15186

  • SevereNHTSA·22V816000·2022-10-31

    2021 Hyundai Santa Fe Hybrid seat belt pretensioners may explode in crash

    Hyundai is recalling 2021-2023 Santa Fe Hybrid and 2022-2023 Santa Fe Plug-In Hybrid vehicles, plus 2023 Genesis G80 Electric vehicles, because seat belt pretensioners may explode in a crash and project metal fragments. Dealers will secure the pretensioners with a cap at no cost.

    Product
    GENESIS — GENESIS, HYUNDAI G80 ELECTRIFIED, SANTA FE HYBRID, SANTA FE PLUG-IN HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V815000·2022-10-31

    Volkswagen and Audi Vehicles Recalled for Tire Pressure Monitoring System Failure

    Volkswagen Group of America is recalling 296,044 Volkswagen and Audi vehicles (model years 2019-2021) because the tire pressure monitoring system may fail to detect simultaneous pressure loss in all four tires, increasing crash risk. Dealers will update the TPMS software at no charge.

    Product
    VOLKSWAGEN — VOLKSWAGEN, AUDI ATLAS CROSS SPORT, Q3, GOLF SPORTWAGEN, A3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V814000·2022-10-31

    Tiffin Motorhomes Recall Multiple 2022-2023 Models for LPG Hose Leak Fire Risk

    Tiffin is recalling approximately 295 motorhomes from 2022-2023 because the LPG hose fitting connected to the regulator may leak at the swivel joint, creating a fire hazard in the presence of an ignition source.

    Product
    TIFFIN — TIFFIN RED 360, ALLEGRO BAY, ALLEGRO BREEZE, PHAETON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V811000·2022-10-28

    Micro Bird Recalls G5 School Buses Due to Power Steering Defect

    Micro Bird is recalling 2019-2022 G5 school buses because a faulty connection may cause sudden loss of power steering and brake assist, increasing crash risk.

    Product
    MICRO BIRD — MICRO BIRD G5 SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V812000·2022-10-28

    Micro Bird Recalls One 2019 G5 Transit Bus for Brake Fluid Leak

    Micro Bird is recalling one 2019 G5 transit bus because a faulty connection may cause power steering fluid loss, reducing brake assist and increasing crash risk.

    Product
    MICRO BIRD — MICRO BIRD G5 TRANSIT BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V810000·2022-10-27

    Hyundai Recalls 2018 Santa Fe Sport Vehicles Due to Fire Risk

    Hyundai is recalling 44,396 2018 Santa Fe Sport vehicles because a faulty ABS module could cause an electrical short and engine compartment fire.

    Product
    HYUNDAI — HYUNDAI SANTA FE SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V808000·2022-10-27

    2022 Chrysler 300 and Dodge vehicles TPMS sensor battery failure

    Chrysler and Dodge are recalling certain 2022 models because the tire pressure monitoring system sensor battery may fail prematurely, potentially increasing the risk of tire failure and crashes.

    Product
    CHRYSLER — CHRYSLER, DODGE 300, CHARGER, CHALLENGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V805000·2022-10-26

    Sunset Park & RV Recalls 2022 Sun Lite and Rush Travel Trailers

    Sunset Park & RV is recalling 2022 Sun Lite and Rush travel trailers because a welded seam on the awning fabric may separate, causing the awning to drop unexpectedly.

    Product
    SUNSET PARK & RV — SUNSET PARK & RV SUNLITE, RUSH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V804000·2022-10-26

    Rearview camera display malfunction in 2022 Lamborghini Urus vehicles

    The infotainment system in certain 2022 Lamborghini Urus vehicles may become damaged, causing the rearview camera display to become inoperative. This reduces rear visibility and increases the risk of a crash.

    Product
    LAMBORGHINI — LAMBORGHINI URUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V807000·2022-10-26

    Volkswagen Atlas and Cross Sport trailing arm bolt defect recall

    Volkswagen is recalling certain 2022 Atlas and 2022-2023 Cross Sport vehicles because driver-side rear trailing arm bolts may loosen and fall out, risking loss of vehicle control.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS, ATLAS CROSS SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V806000·2022-10-26

    Multiple 2021-2022 Audi models recalled for rearview camera failure

    Volkswagen Group of America is recalling certain 2021-2022 Audi vehicles. The infotainment system may fail to display the rearview camera, reducing rear visibility and increasing crash risk.

    Product
    AUDI — AUDI A3, Q8, Q3, Q7
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V803000·2022-10-25

    2022 Porsche 911 GT3 seat belt anchor screws may not be properly tightened

    Porsche is recalling certain 2022 911 GT3 vehicles because the screw attaching the lower seat belt anchor may not have been properly tightened. A loose anchor could detach in a crash, increasing injury risk.

    Product
    PORSCHE — PORSCHE 911 GT3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V801000·2022-10-24

    Gillig Recalls 2022 Low Floor Transit Buses Due to Steering Defect

    Gillig is recalling 388 2022 Low Floor transit buses because a steering shaft grease fitting may damage a protective shroud, potentially causing loss of steering control.

    Product
    GILLIG — GILLIG LOW FLOOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V800000·2022-10-24

    Kia Recalls 2008-2009 Sportage Vehicles for Engine Fire Risk

    Kia is recalling 2008-2009 Sportage vehicles because an engine compartment fire may occur from the Hydraulic Electronic Control Unit, increasing injury risk.

    Product
    KIA — KIA SPORTAGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V799000·2022-10-22

    CAN-AM Ryker Motorcycles Recalled for Loose Harnesses Causing Engine Stall

    CAN-AM is recalling 2019-2023 Ryker motorcycles because electrical harnesses in the front fenders may loosen and rub on the tire, causing a short circuit that can stall the engine while driving.

    Product
    CAN-AM — CAN-AM RYKER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V797000·2022-10-21

    Autocar Xpeditor Steering Column Pinch Bolt Defect Recall

    Autocar is recalling 2021-2023 Xpeditor vehicles because the steering column shaft pinch bolt may be improperly secured and bind, causing sudden loss of steering and increasing crash risk.

    Product
    AUTOCAR — AUTOCAR XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V794000·2022-10-21

    Altec Recalls 2019-2022 Aerial Devices Due to Outrigger Safety Defect

    Altec is recalling 2019-2022 AT41ME aerial devices because the material handling interlocking valve may lose power, allowing the jib winch to operate while outriggers are up, which increases the risk of the unit tipping.

    Product
    ALTEC — ALTEC AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V796000·2022-10-21

    Freightliner Sprinter parking brake failure may cause vehicle rollaway

    The guide bushing on the parking pawl may fatigue and prevent the parking brake from engaging, risking vehicle rollaway. Dealers will provide a free software update to affected 2019-2022 vehicles.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER SPRINTER 2500, SPRINTER 1500, SPRINTER 4500, SPRINTER 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V798000·2022-10-21

    2020 Tesla Model 3 Seat Belt Anchor Reassembly Defect Recall

    Tesla is recalling 2017-2022 Model 3 vehicles because second-row seat belt anchors may have been incorrectly reassembled during prior service work. Defective anchors could impair crash protection, increasing injury risk.

    Product
    TESLA — TESLA MODEL 3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V795000·2022-10-21

    Winnebago View and Navion vehicles LP fuel line routing defect

    Winnebago Industries is recalling certain 2020-2023 View and Navion recreational vehicles. The LP fuel line is routed near the rear wheel well and may contact the tire, creating a fuel leak and fire risk.

    Product
    WINNEBAGO — WINNEBAGO NAVION, VIEW
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V788000·2022-10-20

    E-One Recalls 2022 Fire Apparatus Due to Tie Rod Clamp Cracking

    E-One is recalling 2022 Typhoon N, Cyclone II, and Cyclone N vehicles because improperly heat-treated tie rod clamps may crack, risking sudden loss of steering.

    Product
    E-ONE — E-ONE TYPHOON N, CYCLONE II, CYCLONE N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V790000·2022-10-20

    Orange EV Recalls 2022 e-Triever for Parking Brake Fastener Issue

    Orange EV is recalling 2022 e-Triever vehicles because a loose parking brake fastener may prevent the brake from engaging, increasing the risk of a crash.

    Product
    ORANGE EV — ORANGE EV E-TRIEVER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V792000·2022-10-20

    2023 Ford E-450 Rear Axle Rotor Bolts May Loosen, Causing Wheel Separation

    Ford is recalling certain 2023 E-450 vehicles because rear axle rotor bolts may be improperly tightened, risking wheel separation and increasing crash risk. Dealers will replace affected assemblies at no charge.

    Product
    FORD — FORD E-450
    Category
    Vehicle
    Distribution
    Distributed nationwide