The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3726–3750 of 15186

  • SevereNHTSA·22V908000·2022-12-08

    2023 McLaren Artura recalled for fuel pipe defect increasing fire risk

    McLaren is recalling 164 2023 Artura vehicles because high-pressure fuel pipe nuts may loosen, causing fuel leaks that could lead to fires. Dealers will replace the fuel pipes at no cost.

    Product
    MCLAREN — MCLAREN ARTURA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V905000·2022-12-08

    Hyundai Translead Recalls 2020-2021 Trailers Due to Brake Pad Retaining Clip Defect

    Hyundai Translead is recalling 2020-2021 Dry Van and Reefer Trailers because a loose brake pad retaining clip may detach, reducing brake performance or causing a flat tire.

    Product
    HYUNDAI TRANSLEAD — HYUNDAI TRANSLEAD REEFER TRAILER, DRY VAN TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V910000·2022-12-08

    Navistar Recalls 2023 IC CE and IN RE Buses for Axle Fastener Issue

    Navistar is recalling 2023 IC CE and IN RE commercial buses because incorrectly tightened fasteners may allow the rear axle to shift, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS RE, CE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V904000·2022-12-08

    2019-2022 RAM Pickup Trucks Recalled for Defective Tailgate Latch

    Chrysler is recalling 2019-2022 RAM 1500, 2500, and 3500 pickup trucks because the tailgate may not latch properly due to misaligned strikers. An unintended tailgate opening while driving could result in cargo loss and increased crash risk.

    Product
    RAM — RAM 3500, 2500, 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V907000·2022-12-08

    Subaru Ascent 2019–2022 Recall for Electrical Fire Risk

    Subaru is recalling 2019–2022 Ascent vehicles due to an improperly fastened ground bolt on the PTC heater that could melt and cause an electrical fire.

    Product
    SUBARU — SUBARU ASCENT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V909000·2022-12-08

    School buses recalled for incorrectly tightened rear axle fasteners

    Navistar is recalling certain 2023-2024 IC BUS school buses due to fasteners on the rear axle that may have been tightened incorrectly. This can allow the rear axle to shift, reducing vehicle control and increasing crash risk.

    Product
    IC BUS — IC BUS CESB, RESB, EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V903000·2022-12-08

    GM recalls multiple 2020-2023 vehicles for daytime running light control defect

    General Motors is recalling multiple 2020-2023 models because daytime running lights may fail to turn off when headlights are on, creating glare and visibility hazards.

    Product
    CADILLAC — CADILLAC, CHEVROLET, GMC ESCALADE, ESCALADE ESV, SILVERADO 1500, SUBURBAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V902000·2022-12-07

    Nova Bus Recalls LFS Models for Non-Standard Auxiliary Lighting

    Nova Bus is recalling 2009-2021 LFS and LFS Artic transit buses because non-standard color auxiliary lights may distract other drivers and increase crash risk.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V899000·2022-12-06

    Kia Recalls 2020 Niro EV Vehicles for EPCU Coolant Leak Risk

    Kia is recalling 2020 Niro EV vehicles because a coolant leak in the Electric Power Control Unit may cause loss of drive power, increasing crash risk.

    Product
    KIA — KIA NIRO EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V898000·2022-12-06

    Hino Recalls 2022-2023 Trucks Due to Fuel Pickup Tube Defect

    Hino is recalling 970 specific 2022-2023 models because a fuel tube may restrict fuel flow, potentially causing engine stalls and increasing crash risk.

    Product
    HINO — HINO NJ7A, NJ7B, NV7A, NE7A
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V896000·2022-12-06

    Volvo Recalls 2022-2023 VNL Vehicles for Air Tank Bracket Defect

    Volvo Trucks is recalling certain 2022-2023 VNL vehicles because excessively tightened air tank bracket fasteners may break, allowing the air tank to detach and become a road hazard.

    Product
    VOLVO — VOLVO VNL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V900000·2022-12-06

    KTM 1290 Super Duke R Motorcycles Recalled for Electrical Wiring Defect

    KTM is recalling 2020-2022 1290 Super Duke R motorcycles because the main wiring harness may be misrouted or missing parts, potentially causing an electrical short-circuit and engine stall.

    Product
    KTM — KTM 1290 SUPER DUKE R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V895000·2022-12-05

    Tesla Recalls 2023 Model Y Vehicles for Suspension Fastener Defect

    Tesla is recalling 2023 Model Y vehicles because front suspension fasteners may not be properly attached, which could cause instability and increase crash risk.

    Product
    TESLA — TESLA MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22T022000·2022-12-05

    Continental Tire Recalls Specific Models Due to Sidewall Break Risk

    Continental Tire is recalling specific 4x4 Contact, PureContact LS, and TerrainContact H/T tires because overcuring may cause sidewall breaks or tread separation, increasing crash risk.

    Product
    TIRES:SIDEWALL recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V894000·2022-12-05

    Old School Trailers Recalls 2022 Models Due to Awning Seam Defect

    Old School Trailers is recalling 2022 models because a welded seam on the electric retractable awning may separate, causing the awning to drop and increasing injury risk.

    Product
    OLD SCHOOL TRAILERS — OLD SCHOOL TRAILERS OLD SCHOOL TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V893000·2022-12-02

    Terex Recalls 2022 Aerial Work Platforms Due to Boom Weld Defect

    Terex is recalling 431 units of 2022 C4000, C5000, C6000, C7000, General, and TL vehicles because a seam in the boom structure may have been improperly welded.

    Product
    TEREX — TEREX C5000, TL, C4000, C7000
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V892000·2022-12-02

    Pierce Recalls 2022 Fire Trucks Due to Tie Rod Clamp Cracking

    Pierce Manufacturing is recalling 2022 Saber, Enforcer, and Arrow XT fire trucks because improperly heat-treated tie rod clamps may crack, risking sudden loss of steering.

    Product
    PIERCE — PIERCE ENFORCER, ARROW XT, SABER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V888000·2022-12-01

    Terex Recalls 2022 Outrigger Vehicles Due to Cylinder Drift Risk

    Terex is recalling 2022 Optima TC, XT Pro, and C4000 vehicles because incorrect machining may cause outrigger cylinders to drift, increasing the risk of the machine tipping.

    Product
    TEREX — TEREX OPTIMA TC, XT PRO, C4000
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·23713·2022-12-01

    Kubota RTV-XG850 Utility Vehicles Recall for Steering Shaft Failure

    Kubota is recalling about 19,500 RTV-XG850 utility vehicles because the steering shaft can shear near the power steering housing, causing loss of steering control. No injuries or deaths have been reported.

    Product
    Kubota RTV-XG850 Model Utility Vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide