The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

176–200 of 589

  • CriticalFDA (Devices)·Z-2662-2025·2025-10-08

    MAGNETOM Skyra Fit BioMatrix systems recalled over magnet vent ice blockage

    Siemens is recalling 39 MAGNETOM Skyra Fit BioMatrix systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Skyra Fit BioMatrix. Model Number: 11516217.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2610-2025·2025-10-08

    Reprocessed steerable electrophysiology catheters recalled over residual particulates on surfaces

    Medline is recalling 7,913 reprocessed Livewire Steerable Electrophysiology Catheters because specific lots may carry small residual particulates on patient-contacting surfaces.

    Product
    Reprocessed Livewire Steerable Electrophysiology Catheter Item Numbers 401575RH 401582RH 401600RH 401603RH 401606RH 401652RH 401653RH 401654RH 401904RH 401905RH 401908RH 401914RH 401915RH 401918RH 401932RH 401933RH 401934RH 401938RH 401939RH 401940RH…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2668-2025·2025-10-08

    MAGNETOM Vida Fit MRI systems recalled over magnet vent ice blockage

    Siemens is recalling 41 MAGNETOM Vida Fit MRI systems because an ice blockage in the magnet venting system could stop helium escaping during a quench.

    Product
    MAGNETOM Vida Fit. Model Number: 11410481.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2659-2025·2025-10-08

    MAGNETOM Prisma MRI systems recalled over helium venting ice blockage

    Siemens is recalling 101 MAGNETOM Prisma MRI systems because an ice blockage in the magnet venting system could prevent helium escaping during a quench.

    Product
    MAGNETOM Prisma. Model Number: 10849582.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2566-2025·2025-10-01

    Intubation trays recalled after laryngoscope handle lights failed to illuminate

    Medline is recalling 2,520 intubation and airway kits containing Flexicare BritePro Solo fiber optic laryngoscope handles because the light may fail to illuminate as intended.

    Product
    Medline medical convenience kits labeled as: 1. ADULT INTUBATION TRAY, Kit Number ACC010369B; 2. ADULT ICU INTUBATION TRAY, Kit Number ACC010379A; 3. INTUBATION TRAY, Kit Number ACC010392; 4. INTUBATION KIT, Kit Number ACC010467A; 5. ADULT AIRWAY TRAY, Kit Number…
    Category
    Medical Device
    Distribution
    6 states
  • CriticalFDA (Devices)·Z-2538-2025·2025-09-24

    Wheelchair power assist speed dials recalled over potential loss of control

    SmartDrive MX2+ SpeedControl Dials are recalled because a faulty electrical connection between the dial and the wheelchair motor may cause loss of control. The FDA classified the action as Class I. 25,389 units are affected.

    Product
    Max Mobility/Permobil Smart Drive MX2+ SpeedControl Dial Ref: MX2-3DC use in conjunction with the SmartDrive MX2+ Wheelchair Power Assist component.
    Category
    Medical Device
    Distribution
    52 states
  • CriticalFDA (Devices)·Z-2540-2025·2025-09-24

    SmartDrive speed control dials recalled over faulty motor electrical connection

    SmartDrive MX2+ SpeedControl Dials, REF MX2-3DCMC, are recalled because a faulty electrical connection between the dial and the wheelchair motor may cause loss of control. 8,413 units are affected.

    Product
    Max Mobility/Permobil Smart Drive MX2+ SpeedControl Dial Ref: MX2-3DCMC use in conjunction with the SmartDrive MX2+ Wheelchair Power Assist component.
    Category
    Medical Device
    Distribution
    52 states
  • CriticalFDA (Devices)·Z-2539-2025·2025-09-24

    SmartDrive MX2-3DCK dials recalled over faulty connection to wheelchair motor

    SmartDrive MX2+ SpeedControl Dials, REF MX2-3DCK, are recalled because a faulty electrical connection between the dial and the wheelchair motor may cause loss of control. 15,834 units are affected.

    Product
    Max Mobility/Permobil Smart Drive MX2+ SpeedControl Dial Ref: MX2-3DCK use in conjunction with the SmartDrive MX2+ Wheelchair Power Assist component.
    Category
    Medical Device
    Distribution
    52 states
  • CriticalFDA (Devices)·Z-2483-2025·2025-09-24

    Blood and fluid warming sets recalled to clarify flow rates and temperatures

    3M Ranger Blood/Fluid Warming High Flow Sets are the subject of a field action to clarify flow rates, inlet fluid temperatures and the location of the outlet temperature. The FDA classified it as Class I.

    Product
    3M Ranger Blood/Fluid Warming High Flow Set Catalog Numbers 24355, 24370
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2484-2025·2025-09-17

    Aspiration biopsy needles recalled over undetected deformed atraumatic tips

    ViziShot 2 FLEX single use aspiration needles, model NA-U403SX-4019, are recalled because of the potential for undetected, deformed atraumatic tips. The FDA classified the action as Class I. 104,508 units are affected.

    Product
    ViziShot 2FLEX. Single Use Aspiration Needle. Model Number: NA-U403SX-4019. The ViziShot 2 FLEX tissue biopsy device is made up of four main parts: a handle, a sheath, a needle, and a stylet. The sheath and needle are attached to the handle, and the stylet, which is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2436-2025·2025-09-10

    TruSteer transseptal access systems recalled over higher air embolism risk

    Boston Scientific is recalling WATCHMAN TruSteer Access Systems after identifying a higher likelihood of air embolism when procedures are performed without positive pressure-controlled ventilation.

    Product
    WATCHMAN TruSteer Access System, US, Material Number (UPN) M635TU90050;intended to provide vascular and transseptal access for the family of WATCHMAN FLX LAAC Devices with Delivery Systems.
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-2333-2025·2025-09-10

    Syringe pumps recalled over false motor movement system error messages

    Baxter is issuing an urgent correction for Novum IQ Syringe Pumps, product code 40800BAXUS, over software anomalies causing a blank Run screen or a false motor movement system error. 10,101 units are affected.

    Product
    Novum IQ Syringe Pump, Product Code 40800BAXUS, infusion pump
    Category
    Medical Device
    Distribution
    1 state
  • CriticalFDA (Devices)·Z-2431-2025·2025-09-10

    WATCHMAN TruSeal access systems recalled over air embolism during transseptal access

    Boston Scientific is recalling WATCHMAN TruSeal Access System SGL, US, after identifying a higher likelihood of air embolism when procedures are performed without positive pressure-controlled ventilation.

    Product
    WATCHMAN TruSeal Access System SGL, US, Material Number (UPN) M635TU70010; intended to provide vascular and transseptal access for all WATCHMAN Left Atrial Appendage Closure Devices with Delivery Systems.
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-2448-2025·2025-09-10

    Dexcom G7 watchOS app recalled because sensor failure alerts are missing

    The Dexcom G7 CGM watchOS App, versions 2.8.0 and earlier, is recalled because it does not give the expected Sensor Failed alert and silently ends the session. 907,842 units are affected.

    Product
    Brand Name: Dexcom G7 Continuous Glucose Monitoring System Product Name: Dexcom G7 CGM watchOS App Model/Catalog Number: SW13355 Software Version: versions 2.8.0 and earlier Product Description: Dexcom G7 CGM watchOS App - The watchOS app is installed along with the iOS…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2480-2025·2025-09-10

    Left heart vent catheters 13FR recalled because they may not retain shape

    DLP Left Heart Vent Catheters, model 12113, are recalled because the catheters may not retain their shape. The FDA classified the action as Class I. 34,549 units are affected.

    Product
    DLP Left Heart Vent Catheter Malleable body and vented connector, SUCTION 12113 LV VENT 13FR, Model Number 12113
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2482-2025·2025-09-10

    Left heart vent catheters recalled because they may not retain shape

    DLP Left Heart Vent Catheters, model 12115, are recalled because the catheters may not retain their shape. The FDA classified the action as Class I. 25,261 units are affected.

    Product
    DLP Left Heart Vent Catheter Malleable body and vented connector, SUCTION 12115 LV VENT 15FR, Model Number 12115
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2454-2025·2025-09-10

    Wheelchair joysticks recalled over unintended movement on power-up

    Micro Joystick R-net wheelchair controls with firmware 2.3 or lower are recalled because timing variations may skip the neutral check, producing unintended movement on power-up. 3 units are affected.

    Product
    Micro Joystick R-net. Electrical wheelchair component.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2457-2025·2025-09-10

    IDM-MULTI-R wheelchair controls recalled over unintended movement at power-up

    IDM-MULTI-R wheelchair components with firmware 2.3 or lower are recalled because timing variations may skip the neutral check, producing unintended movement on power-up. 15 units are affected.

    Product
    IDM-MULTI-R. Electrical wheelchair component.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2435-2025·2025-09-10

    FXD Curve double access systems recalled over transseptal air embolism risk

    Boston Scientific is recalling WATCHMAN FXD Curve Access System Dbl after identifying a higher likelihood of air embolism when procedures are performed without positive pressure-controlled ventilation.

    Product
    WATCHMAN FXD Curve Access System Dbl, US, Material Number (UPN) M635TU80020; intended to provide vascular and transseptal access for the family of WATCHMAN FLX LAAC Devices with Delivery Systems.
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-2334-2025·2025-09-10

    Novum IQ syringe pumps recalled over software anomalies affecting the run screen

    Baxter is issuing an urgent correction for Novum IQ Syringe Pumps, product code 40700BAX, over software anomalies that may cause a blank Run screen or a false motor movement system error. 22,703 units are affected.

    Product
    Novum IQ Syringe Pump, Product Code 40700BAX, infusion pump
    Category
    Medical Device
    Distribution
    1 state
  • CriticalFDA (Devices)·Z-2432-2025·2025-09-10

    TruSeal DBL access systems recalled over air embolism risk without ventilation

    Boston Scientific is recalling WATCHMAN TruSeal Access System DBL, US, after identifying a higher likelihood of air embolism when procedures are performed without positive pressure-controlled ventilation.

    Product
    WATCHMAN TruSeal Access System DBL, US, Material Number (UPN) M635TU70020; intended to provide vascular and transseptal access for all WATCHMAN Left Atrial Appendage Closure Devices with Delivery Systems.
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-2449-2025·2025-09-10

    Dexcom ONE+ Android app recalled over missing sensor failure alerts

    The Dexcom ONE+ Android CGM App, versions 1.4.0 and earlier, is recalled because it does not give the expected Sensor Failed alert and silently ends the session. 41,629 units are affected.

    Product
    Brand Name: Dexcom ONE+ Continuous Glucose Monitoring System Product Name: Dexcom ONE+ Android CGM App Model/Catalog Number: SW14245 Software Version: versions 1.4.0 and earlier Product Description: Dexcom ONE+ Androind CGM App Component: Dexcom ONE+ Continuous Glucose…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2459-2025·2025-09-10

    IDM-ARLITE-R wheelchair controls recalled over unintended movement on power-up

    IDM-ARLITE-R wheelchair components with firmware 2.3 or lower are recalled because timing variations may skip the neutral check, producing unintended movement on power-up. 25 units are affected.

    Product
    IDM-ARLITE-R. Electrical wheelchair component.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2456-2025·2025-09-10

    IDM-MICRO-R wheelchair controls recalled over unintended movement on power-up

    IDM-MICRO-R wheelchair components with firmware 2.3 or lower are recalled because timing variations may skip the neutral check, producing unintended movement on power-up. 15 units are affected.

    Product
    IDM-MICRO-R. Electrical wheelchair component.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2332-2025·2025-09-10

    Novum IQ large volume pumps recalled over software anomalies causing blank screens

    Baxter is issuing an urgent correction for Novum IQ Large Volume Pumps over software anomalies that may result in a blank Run screen. 43,922 units are affected.

    Product
    Novum IQ LVP (Large Volume Pump), Product Code 40700BAXUS, infusion pump
    Category
    Medical Device
    Distribution
    1 state