The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

11276–11300 of 15086

  • SevereNHTSA·15V214000·2015-04-10

    Land Rover Recalls 2015 LR4 Models Due to ABS Software Error

    Land Rover is recalling 2015 LR4 vehicles because an ABS software error may disable stability and traction control systems, increasing crash risk.

    Product
    LAND ROVER — LAND ROVER LR4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V210000·2015-04-08

    KTM Recalls 2015 690 Enduro R Motorcycles Due to Rear Brake Line Damage

    KTM is recalling 409 model year 2015 690 Enduro R motorcycles because the rear brake line may be damaged, potentially causing a loss of braking ability and increasing crash risk.

    Product
    KTM — KTM 690 ENDURO R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V207000·2015-04-07

    Keystone and Dutchmen Trailers Recalled for Wheel Stud Defect

    Keystone RV Company is recalling 2015-2016 Keystone and Dutchmen trailers because wheel studs may break, potentially causing the wheel to detach.

    Product
    DUTCHMEN — DUTCHMEN, KEYSTONE ASPEN TRAIL, DENALI, SPRINTER, SPRINGDALE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15E029000·2015-04-07

    Lippert Trailer Axle Hubs Recalled for Wheel Stud Failure Risk

    Lippert Components is recalling specific trailer axle hubs because wheel mounting studs may fail, potentially causing wheel separation and a crash.

    Product
    SUSPENSION:REAR:AXLE:NON-POWERED AXLE ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V208000·2015-04-07

    Hino Recalls 2015-2016 Trucks Due to Front Axle U-Bolt Defect

    Hino is recalling 2015-2016 238, 258, 268, and 338 trucks because overtightened front axle U-bolts may fail, causing loss of steering.

    Product
    HINO — HINO 238, 268, 258, 338
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V209000·2015-04-07

    Highland Ridge RV Recalls 2015-2016 Trailers Due to Slide Room Defect

    Highland Ridge RV is recalling 238 model year 2015-2016 travel and fifth wheel trailers because slide room screws may fail, allowing the room to extend while driving and increasing crash risk.

    Product
    HIGHLAND RIDGE TT — HIGHLAND RIDGE TT, HIGHLAND RIDGE FW JOURNEYER, LIGHT, MESA RIDGE, ROAMER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V204000·2015-04-06

    Autocar Recalls ACX Garbage Trucks Due to Cross Member Bracket Failure

    Autocar is recalling 2013-2015 ACX front-end loader garbage trucks because mounting brackets may fail, causing the cross member to detach and creating road hazards.

    Product
    AUTOCAR — AUTOCAR ACX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V201000·2015-04-06

    GM Recalls 2004 Buick, Chevrolet, and Pontiac Vehicles for Engine Oil Leak

    General Motors is recalling specific 2004 Buick, Chevrolet, and Pontiac vehicles because a leaking valve cover gasket may cause engine oil to drip onto the exhaust manifold, increasing the risk of a fire.

    Product
    CHEVROLET — CHEVROLET, BUICK, PONTIAC IMPALA, REGAL, MONTE CARLO, GRAND PRIX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15E028000·2015-04-06

    Bosch Fuel Delivery Module Recall Due to Improper Nickel Plating

    Bosch is recalling fuel delivery modules with improper nickel plating that may cause the fuel pump to fail, leading to vehicle stalling and increased crash risk.

    Product
    FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V203000·2015-04-06

    Forest River Recalls Fifth Wheel and Travel Trailers Due to Slide Room Defect

    Forest River is recalling specific 2015-2016 fifth wheel and travel trailers because slide room screws may fail, allowing the room to extend while driving and increasing crash risk.

    Product
    TRACER — TRACER, PURSUIT, GEORGETOWN TRT3200BHT, 31BD, GT335, CAF3825FL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V205000·2015-04-06

    BMW Recalls 2005-2008 MINI Cooper Models Due to Air Bag Defect

    BMW is recalling 91,800 MINI Cooper vehicles because the front passenger air bag may not deploy in a crash due to a faulty seat mat.

    Product
    MINI — MINI COOPER S CONVERTIBLE, COOPER CONVERTIBLE, COOPER, COOPER S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V197000·2015-04-03

    Nissan Recalls 2014 Rogue Vehicles Due to Fuel Pump Defect

    Nissan is recalling 2014 Rogue vehicles because a fuel pump defect may cause the vehicle to stall without warning, increasing the risk of a crash.

    Product
    NISSAN — NISSAN ROGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V199000·2015-04-03

    Heartland Recalls Fifth Wheel and Travel Trailers Due to Bolt Failure Risk

    Heartland is recalling 2015-2016 fifth wheel and travel trailers because bolts attaching the expanding room may fail, causing the room to extend while driving and increasing crash risk.

    Product
    HEARTLAND — HEARTLAND TORQUE, ELKRIDGE, LANDMARK 365, PROWLER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V196000·2015-04-03

    Kenworth T680 and T880 Trucks Recalled for Axle Lubrication Defect

    PACCAR is recalling 2015-2016 Kenworth T680 and T880 trucks because inadequate axle lubrication may cause bearing failure, increasing the risk of a wheel-end fire or crash.

    Product
    KENWORTH — KENWORTH T680, T880
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V200000·2015-04-03

    Audi Recalls 2015 Q3 Vehicles Due to Sunroof Safety Defect

    Volkswagen Group of America is recalling 3,646 2015 Audi Q3 vehicles because the sunroof may continue closing after the vehicle is turned off, posing an injury risk.

    Product
    AUDI — AUDI Q3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V198000·2015-04-03

    Heartland Recalls 2015 Trailers Due to Step Rivet Failure Risk

    Heartland is recalling 2015 fifth wheel and travel trailers because a rivet on the quad entry steps may shear, causing the steps to fail and increasing the risk of injury.

    Product
    HEARTLAND — HEARTLAND ELKRIDGE, ROAD WARRIOR, LANDMARK 365, BIGHORN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V195000·2015-04-01

    Mitsubishi Fuso Trucks Recalled for Engine Timing Chain Bolt Issue

    Mitsubishi Fuso is recalling certain FEC72 and FEC92 trucks because an improperly tightened engine bolt may cause an oil leak and engine seizure, increasing crash risk.

    Product
    MITSUBISHI FUSO — MITSUBISHI FUSO FEC92, FEC72
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V194000·2015-04-01

    Volkswagen Recalls 2009-2010 Routan Vehicles for Ignition Switch Defect

    Volkswagen is recalling 2009-2010 Routan vehicles because the ignition switch may move out of the run position, turning off the engine and disabling safety systems like airbags.

    Product
    VOLKSWAGEN — VOLKSWAGEN ROUTAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15E027000·2015-04-01

    Buy4easy Recalls TMS HY-809 Motorcycle Helmets for Impact Protection Defects

    Buy4easy is recalling TMS HY-809 motorcycle half-helmets because they may fail to adequately dampen impacts and lack required labeling, increasing injury risk in crashes.

    Product
    EQUIPMENT:MOTORCYCLE:HELMETS recall
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V191000·2015-03-31

    Thor Motor Coach Recalls 2015 Siesta and Citation Motorhomes

    Thor Motor Coach is recalling 2015 Siesta and Citation motorhomes because an incorrectly installed door component may make doors harder to open after a crash.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH SIESTA, CITATION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V189000·2015-03-31

    BMW Recalls 2014-2015 Models for Fuel Pump Defect

    BMW is recalling 18,054 vehicles due to a fuel pump defect that may cause the vehicle to stall without warning, increasing crash risk.

    Product
    BMW — BMW 428I, 435I, 328XI, 328I
    Category
    Vehicle
    Distribution
    Distributed nationwide